SNMPv3 Notify Table configuration

SNMPv3 uses Notification Originator to send out traps. A notification typically monitors a system for particular events or conditions, and generates Notification-Class messages based on these events or conditions.

The following table describes the SNMPv3 Notify Table Configuration commands.

Table 70 SNMPv3 Notify Table Configuration commands

Command

Description

snmp-server notify <1-16>

Defines a locally arbitrary but unique identifier associated with this SNMP notify

name <1-32 characters>

entry.

 

Command mode: Global configuration

snmp-server notify <1-16>tag <1-255 characters>

Defines a tag of 255 characters maximum that contains a tag value which is used to select entries in the Target Address Table. Any entry in the snmpTargetAddrTable, that matches the value of this tag, is selected. Command mode: Global configuration

no snmp-server notify <1-

Deletes the notify table entry.

16>

Command mode: Global configuration

show snmp-server notify

Displays the current notify table configuration.

<1-16>

Command mode: All

System Access configuration

The following table describes the System Access Configuration commands.

Table 71 System Access Configuration commands

Command

Description

[no] access http enable

Enables or disables HTTP (Web) access to the Browser-based Interface. It

 

is enabled by default.

 

Command mode: Global configuration

access http port <TCP port

Sets the switch port used for serving switch Web content. The default is

number>

HTTP port 80.

 

Command mode: Global configuration

[no] access snmp {read-

Disables or provides read-only/write-read SNMP access.

only read-write}

Command mode: Global configuration

access telnet port <TCP

Sets an optional telnet server port number for cases where the server listens

port number>

for telnet sessions on a non-standard port.

 

Command mode: Global configuration

access tftp-port <TFTP port

Sets an optional telnet server port number for cases where the server listens

number>

for TFTP sessions on a non-standard port.

 

Command mode: Global configuration

show access

Displays the current system access parameters.

 

Command mode: All

Management Networks configuration

The following table describes the Management Networks Configuration commands. You can configure up to 10 management networks on the switch.

Table 72 Management Networks Configuration commands

Command

Description

access management-network <IP

Adds a defined network through which switch access is allowed

address> <IP mask>

through Telnet, SNMP, RIP, or the browser-based interface. A range

 

of IP addresses is produced when used with a network mask

 

address. Specify an IP address and mask address in dotted-decimal

 

notation.

 

Command mode: Global configuration

no access management-network <IP

Removes a defined network, which consists of a management

address> <IP mask>

network address and a management network mask address.

 

Command mode: Global configuration

show access management-network

Displays the current management networks parameters.

 

Command mode: All except User EXEC

Configuration Commands 70

Image 70
Contents N8406-022 1Gb Intelligent L2 Switch Page Contents Statistics commands Operations Commands Introduction Connecting to the switchIscli Reference Additional referencesEstablishing a Telnet connection Setting an IP addressTelnet 1Gb Intelligent L2 Switch IP address Establishing an SSH connectionAccessing the switch # ssh user@1Gb Intelligent L2 Switch IP addressPing IP address Idle timeoutTypographical conventions Show portchannel 1-12hashinformationShow ip interface Show spanning-tree stpIscli Command Modes Accessing the IscliIscli basics Global commands Switchconfig# spanning-tree stp 1 bridge hello Command line interface shortcutsCommand abbreviation Switchconfig# sp stp 1 br hInformation Commands System Information commands SNMPv3 Information commandsUser Name SNMPv3 USM User Table informationSNMPv3 View Table information ProtocolGroup Name SNMPv3 Access Table informationView Name PrefixSec Model SNMPv3 Group Table informationSNMPv3 Community Table information Index Name User Name Tag Trap1 Public V1v2only V1v2trapSNMPv3 Target Parameters Table information SNMPv3 Target Address Table informationSec Level SNMPv3 Notify Table information NameTag V1v2trapv1v2trapShow snmp-server v3 Command mode All SNMPv3 dumpSystem information Show recent syslog messages Usernames Enabled Oper Disabled Admin Always EnabledSystem user information Layer 2 information FDB information commands Show all FDB informationSpanning Tree information Show spanning-tree stp 1-32informationRapid Spanning Tree and Multiple Spanning Tree information Priority bridge Designated bridgeDesg 8000-000342fa3b80 8002 128 2000 Common Internal Spanning Tree informationDesg 8000-000342fa3b80 8001 P2P, Edge 128 2000 128 2000Cist Root Disabled DSBDiscarding DISC, Learning LRN, Forwarding FWD, or Trunk group information Trunk group 1, Enabled port state STG 1 forwardingVlan information Layer 3 information ARP informationShow all ARP entry information Show layer3 information Command mode AllIP information ARP address list informationRmon Information Igmp multicast group informationIgmp multicast router port information Rmon history informationShow rmon alarm Rmon alarm informationInterval Rmon event information Show rmon eventLink status information Port Tag Rmon Pvid Port informationVLANs Logical Port to GEA Port mapping Show geaport Command mode AllUplink Failure Detection information Information dump Statistics commands Port StatisticsBridging statistics Ethernet statisticsDot3StatsInternalMacTransmitError Dot3StatsAlignmentErrorsDot3StatsFCSErrors Dot3StatsSingleCollisionFramesInterface statistics Internet Protocol IP statistics Show interface gigabitethernet port number ip-countersFDB statistics Layer 2 statisticsLink statistics Show interface gigabitethernet port number link-countersLayer 3 statistics IP statisticsARP statistics ARP statistics ArpEntriesCur ArpEntriesHighWaterIcmp statistics DNS statisticsDNS statistics DnsInRequests DnsOutRequests DnsBadRequests TCP statistics UDP statistics Show mp tcp-block Management Processor statisticsIgmp Multicast Group statistics Show mp udp-blockAll UDP allocated control blocks Listen 10ad41e8/10ad5790161 CPU statistics Show snmp-server counters Command mode All except User ExecSnmp statistics Decoding Snmp messages received Show ntp counters Command mode All NTP statisticsUplink Failure Detection statistics Statistics dumpSystem configuration Configuration CommandsSaving the configuration Viewing and saving changesSystem host log configuration Secure Shell Server configuration Radius server configuration TACACS+ server configuration NTP server configuration System Snmp configuration SNMPv3 configuration Privacy-protocol desnone User Security Model configurationPrivacy-password password No snmp-server userSNMPv3 View configuration View-based Access Control Model configurationSNMPv3 Group configuration SNMPv3 Community Table configurationSNMPv3 Target Address Table configuration SNMPv3 Target Parameters Table configurationSystem Access configuration SNMPv3 Notify Table configurationManagement Networks configuration User Access Control configuration User ID configurationHttps Access configuration Port configuration Temporarily disabling a portLayer 2 configuration Port link configurationSpanning-tree mstp Spanning-tree mrst ModeSpanning-tree mrst Enable NameCommon Internal Spanning Tree configuration Cist bridge configurationCist port configuration Spanning Tree configuration Bridge Spanning Tree configuration Spanning Tree port configuration Trunk configuration Forwarding Database configurationStatic FDB configuration Layer 3 configuration Vlan configurationIP interface configuration Default Gateway configurationIgmp configuration Address Resolution Protocol configurationIgmp snooping configuration Igmp static multicast router configuration Igmp filtering configurationIgmp filtering port configuration Domain Name System configurationIgmp filter definition Rmon history configuration Remote Monitoring configurationRmon event configuration Rmon alarm configuration Port mirroring Uplink Failure Detection configurationPort-based port mirroring Link to Monitor configuration Configuration DumpFailure Detection Pair configuration Link to Disable configurationSaving the active switch configuration Restoring the active switch configurationOperations Commands Operations-level port optionsDownloading new software to the switch Boot OptionsUpdating the switch software image Router# copy tftp image1image2boot-imageSwitch# copy image1image2boot-image tftp Uploading a software image from the switchRouterconfig# boot image image1image2 Selecting a software image to runResetting the switch Selecting a configuration blockAccessing the AOS CLI System maintenance Maintenance CommandsForwarding Database maintenance ARP cache maintenance Debugging optionsIgmp Mrouter maintenance Igmp Snooping maintenanceUuencode flash dump Switch# clear flash-dump Panic commandSwitch# copy flash-dump tftp server filename Tftp system dump putUnscheduled system dumps Index
Related manuals
Manual 62 pages 46.6 Kb

N8406-022 specifications

The NEC N8406-022 is a robust and versatile networking device designed primarily for organizations requiring high-performance connectivity solutions. As part of NEC's extensive portfolio of networking equipment, the N8406-022 is engineered to address the demands of modern enterprise environments, ensuring seamless communication and data processing capabilities.

One of the key features of the N8406-022 is its multi-layer switching functionality. This device supports Layer 2 and Layer 3 switching, allowing for efficient data routing and reducing latency within local area networks (LANs). This capability is particularly beneficial for businesses that rely on real-time data access and transfer, such as those in financial services, media, and telecommunications.

The N8406-022 is equipped with advanced Quality of Service (QoS) features that help prioritize critical network traffic. This means that voice and video data packets can be given precedence over less time-sensitive information, ensuring that essential communication remains clear and uninterrupted. This is crucial for organizations leveraging VoIP and video conferencing solutions.

In terms of connectivity, the NEC N8406-022 offers a variety of ports, including multiple Gigabit Ethernet ports, which facilitate high-speed data transfer and enable seamless integration into existing network infrastructures. The device may also include 10 Gigabit SFP+ ports, providing the flexibility for high-capacity uplinks to support bandwidth-intensive applications and storage solutions.

Security is another focal point of the NEC N8406-022, with integrated features such as VLAN support, access control lists (ACLs), and port security measures. These capabilities protect sensitive data from unauthorized access and ensure that only legitimate users and devices can connect to the network.

Moreover, the N8406-022 often incorporates advanced energy-efficient technologies that minimize power consumption without compromising performance. This not only contributes to operational cost savings but also supports organizations in their sustainability efforts.

With its combination of performance, security, and energy efficiency, the NEC N8406-022 stands out as a reliable networking solution suitable for a wide range of enterprises looking to enhance their connectivity and operational efficiency. Whether deployed in data centers or as part of a corporate network, this device is built to meet the evolving demands of today’s digital landscape.