Kodak A-61557 manual December

Page 37

MICR recognition

Recognition algorithm for E13B, CMC7 or CMC0 standards performed by the API

 

 

MICR data transmission

Analog waveform through the USB port

 

 

Temperature

Operating: 60 - 90°F (15 - 32°C)

 

Storage: 32 - 104°F (0 - 40°C)

 

 

Humidity

35 to 85% non-condensing

 

 

Scanner Dimensions

Height: 6.8 in. / 17.3 cm

 

Length: 11 in. / 27.9 cm

 

Depth: 5.1 in. / 12.9 cm

 

Weight: 5 lbs. / 2.3 kg

 

Footprint: 5.1 in. / 12.9 cm x 8 6 in. / 21.8 cm

 

 

Acoustic Noise

56 Lpa (dbA) peak @ the operator position

(Sound Power level)

 

 

 

Electrical requirements

Power Consumption: 50 watts (maximum)

 

115 Vac ± 10% 60 Hz

 

230 Vac ± 10% 50 Hz

 

 

Agency approvals

UL, CUL, FCC, Class A, CE, EN55022 Class A

 

 

Product life

5,000,000 checks

 

 

Duty cycle

3,000 to 5,000 checks per day

i6060 or i6090 Check Scanner

MTTR (Mean time to repair)

20 minutes

 

 

Optional Printer

Endorse back side of document prior to capturing the scanned image

 

12 nozzle printing resolution (96 dpi)

 

Cartridge: Hewlett Packard 6602A (up to 7,000,000 characters)

 

 

34

A-61557 December 2006

Image 37
Contents I6000 Series Check Scanners Contents Safety information User precautions European Union Safety and regulatory agency approvalsUnited States Acoustic emission EMC statementsEuropean Union Peoples Republic of ChinaIntroduction Scanner featuresWhat’s in the box Getting StartedRecommended MinimumDecember Windows Installing the driversDecember Page December Update Device Driver Wizard window is displayed Click Next December Windows XP December Page Select No, not this time and click Next Page December Front view Scanner componentsBack view I6090 Scanners only Inside viewTurning the scanner on and off Using the ScannerDocument Size Documents Scanning yourFor i6060/i6090 Check Scanners For i6015 Check ScannerDaily cleaning MaintenanceProcedures Description CAT NoTo clean the remaining drive rollers Procedure Weekly cleaningDecember Page Cartridge Replacing the inkIndicator lights TroubleshootingScanner State Clearing a document jam Error Codes Possible Solution Problem solvingHelpful hints Problem Possible Solution Image quality issuesAppendix a Specifications Scanner Dimensions TemperatureMicr recognition Micr data transmissionDecember