Kodak 9500 manual Scsi status responses, Status Response Code Meaning

Page 20

SCSI status responses

In the SCSI communication mode, a function is considered

 

incomplete until a valid status response is received from the other

 

end of the SCSI link. There are three valid SCSI status

 

responses:

 

 

 

 

 

 

 

Status Response

Code

Meaning

 

 

 

 

 

Good Status

00H

The frame was successfully

 

 

 

received and individual fields

 

 

 

within the frame contained legal

 

 

 

characters.

 

 

 

 

 

Check Condition

02H

A special condition occurred. A

 

Status

 

SCSI Request Sense command

 

 

 

is required to obtain information

 

 

 

about the cause of the condition.

 

 

 

Some host adapters

 

 

 

automatically perform a Request

 

 

 

Sense command.

 

 

 

 

 

Busy Status

08H

Target is unable to accept

 

 

 

commands at the present time.

 

 

 

Host should try again. The host

 

 

 

should wait a minimum of 100

 

 

 

milliseconds before trying again.

 

 

 

 

 

NOTE: "H" in the list above indicates hexadecimal notation.

5-4

A-61124 March 1999

Image 20 Contents
Integrator’s Guide Introduction Document sizeAbout this guide Scanning documents SetupScanning Concepts Error handling March Fault recovery Interactive/online method Batch/offline methodImage header contents Image HeadersResolution Image addressHeader flags Compression typeSkew Angle Bar code header informationImage Deskew Flag Offset Format Dynamic Data Set by Command Image header formatMarch Default Image Header Format Retrieving images and headers Requested Resultant Last TransferRecommended retrieval methods To read the header and then read the image Scanner Host Communications Scsi data ratesScsi Interface Scsi overview Scsi busScsi interface signal lines Issuing Scsi commandsMarch Scsi status responses Status Response Code MeaningScsi message responses Message Code Direction Function/Action Scsi SpecScsi conformance Scsi commands Scsi command summaryCommand Op Command NumberDefine Window Parameters command Command block descriptorCommand op code 24H Scsi Specification Section Define Window Parameters headerDefine Window descriptor bytes Define Window Parameters data Descriptor Data DefinitionDescriptor Data Definition Get Window command Command op code 25H Scsi Specification SectionGet Window data Get Window Parameters headerGet Window Parameters header data Get Window descriptor bytes Get Window Parameters data Descriptor Data Definition Inquiry descriptor bytes Inquiry commandCommand op code 12H Scsi Specification Section Inquiry data Read data Read commandCommand op code 28H Scsi Specification Section Release Unit command Command op code 17H Scsi Specification SectionRequest Sense descriptor bytes Request Sense commandCommand op code 03H Scsi Specification Section Request Sense data ILIDescription Seq. Id# Required Error Trans Panel Reserve Unit command Scan commandCommand op code 16H Scsi Specification Section Command op code 1BH Scsi Specification SectionSend data Send commandCommand op code 2AH Scsi Specification Section Using the Send command for scanner- unique commands Command blockTest Unit Ready command Command op code 00H Scsi Specification SectionScanner-unique Commands Scanner-unique command formatCommand summary ScsiMarch Commands AX/Y/Z Cropping/ Auto CroppingDescription Values DX No scan EX Bit order FX/Y/Z Compression GC Last image address Information returned is in the following formatGX End of job HA Set mode HC Next image address HC command sets the image address for the next documentJA Define mode JA command ExampleJX/Y/Z Scan threshold Cont NX/Y/Z command selects the Noise filter for the current mode SX/Y/Z Reverse image TX Simplex/duplex status W command enables or disables document skew correction YX/Y/Z Border Reduction WX/Y/Z Skew CorrectionScanner-unique command samples Temporarily overriding a group of parametersPermanently changing individual parameters Permanently changing a group of parameters Recommended usage of scanner-unique commands Usage Protocol Pinouts Sample interfaces Diagnostic Interface J45/COIN3Pin J45 Signals Appendix a Glossary Error diffusion mode Document image levelGray scale image Gray levelsMultilevel indexing NoiseNoise filter PatchScanner-unique command ScalingScreening SeedAccessory-specific Appendix B Reference MaterialsOrdering publications United States and CanadaAppendix C Assigning Image Addresses March Appendix D Image Processing Parameter Defaults Image processing parametersModes Parameter Command 13,17 14,18 11,15 12,16 Table D-2 Scanner Recommended Image processing parameters Filter∙ YX/Y/Z ∙ AX/Y/Z March Adaptive Threshold Processing separates the foreground Appendix E Image ProcessingTerminology Reverse imaging Simplex/duplex selection Image processing capabilitiesAuto-cropping Compression is used to reduce the number of bytes needed for Contrast without ATP 61122/A-61124 March 61122/A-61124 March Noise filter 61122/A-61124 March Resolution Product Resolution Base Resolution DpiScreening/Dithering Bit/pixel image. The thresholding value ranges from 0 to 61122/A-61124 March ATP Contrast settings Adaptive Threshold Processor ATP accessoryImage processing settings for the ATP Image a Image B ATP Threshold settings Image C Image DScanner/Microimager Skew Detection and CorrectionAuto-cropping Correction and auto-cropping workExample Full width of Scanner Border reduction Border reductionEvaluating scanned images Source image typesScanned images Printed ImagesComputer-generated images Photographic imagesEvaluation criteria TargetStaircasing AliasingImage resolution Figure C61122/A-61124 March Brightness By counting the number of black and white stepsDocument A G I N G