Emerson GXT5000R-208 user manual United States, Asia 23F, Allied Kajima Bldg

Page 32

POWER AVAILABILITY

GXT5000R-208

with GXT5VBATTW120 / GXT5VBATT Battery Cabinets

USER MANUAL

 

The Company Behind the Products

With over a million installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics:

Environmental systems—Close-control air conditioning from 1 to 60 tons

Power conditioning and UPS with power ranges from 300 VA to more than 1000 kVA

Integrated systems that provide both environmental and power protection in a single, flexible package

Monitoring and control—From systems of any size or location, on-site or remote

Service and support through more than 100 service centers around the world and a 24/7 Customer Response Center

While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

© 2002 Liebert Corporation

All rights reserved throughout the world. Specifications subject to change without notice.

®Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.

23156, Rev. 0 (7/02)

Technical Support/Service

Web Site

www.liebert.com

Monitoring 800-222-5877 monitoring@liebert.com Outside the US: 614-841-6755

Single-Phase UPS 800-222-5877 upstech@liebert.com Outside the US: 614-841-6755

Three-Phase UPS 800-543-2378 powertech@liebert.com

Environmental Systems

800-543-2778

Outside the United States

614-888-0246

Locations

United States

1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229

Italy Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) +39 049 9719 111 Fax: +39 049 5841 257

Asia 23F, Allied Kajima Bldg.

138 Gloucester Road Wanchai Hong Kong

+852 2 572 2201 Fax: +852 2 831 0114

Image 32
Contents GXT5000R-208 Page Table of Contents Figures Important Safety Instructions Service Personnel Information Glossary of Symbols Introduction and System Description Major Components Auxiliary 120V / 400VA Power Dynamic BypassControl panel Air vents DB-9 connector No user connectionGeneral Description GXT5VBATT battery cabinet Rear view External battery connectorsGeneral Installation Controls and Indicators Fault Indicator Battery capacity indicatorsOn Bypass indicator 1 amber LED Modes of Operation Normal Mode OperationBattery Mode Operation Bypass Mode Battery Recharge ModeOperating Instructions Turn OnManual Bypass StandbyProgramming the GXT5000R-208 for Battery Cabinet Count Optional Batteries Programmable RUN TimeProcedure to confirm the battery count Procedure to change the battery countPin Configuration CommunicationsRelay Interface Card Pin Function OperationEPO DB-9 Adapter Serial CommunicationsSerial Cable UPS Communications with Intellislot Maintenance Troubleshooting Overvoltage fault Battery modeOverload alarm Inverter modeWeight lbs kg SpecificationsDimensions inches mm Battery Cabinet Specifications GXT5VBATTW120Page Page United States Asia 23F, Allied Kajima Bldg
Related manuals
Manual 32 pages 29.17 Kb

GXT5000R-208 specifications

The Emerson GXT5000R-208 is a high-performance uninterruptible power supply (UPS) designed to deliver reliable power protection for critical systems in data centers, industrial applications, and other mission-critical environments. This UPS is engineered for efficiency, redundancy, and performance, making it a trusted choice among IT professionals and facility managers.

One of the key features of the GXT5000R-208 is its double-conversion online technology. This technology ensures that the output power is consistent and free from fluctuations, providing pure sine wave output. This feature is particularly important for sensitive electronic equipment, as it maintains the integrity and operational stability of critical systems even in the event of input power disturbances such as surges, sags, or outages.

The GXT5000R-208 is capable of delivering a power capacity of 5000 VA / 5000 W with a nominal input voltage of 208-volt systems. Its advanced design allows for easy adaptability to various configurations, making it suitable for both single-phase and three-phase applications. The UPS is equipped with a wide input voltage range, which enhances its compatibility with different electrical infrastructures.

Another notable characteristic of the Emerson GXT5000R-208 is its modular design. The UPS can be easily expanded or reconfigured according to the changing needs of the facility, offering scalability for future growth. With hot-swappable batteries, users can perform maintenance or upgrades without downtime, ensuring continuous operation.

The GXT5000R-208 also incorporates powerful monitoring and management features. It comes with an intuitive LCD display that provides real-time information regarding the UPS status, battery health, and operational parameters. The UPS can also be integrated with various management software solutions, allowing for remote monitoring and control via SNMP, USB, or RS-232 connections.

Furthermore, the unit is built with a robust battery management system, ensuring optimal battery performance and longevity. Its intelligent charging system reduces the risk of battery overcharging, thus extending battery life and enhancing overall system reliability.

In summary, the Emerson GXT5000R-208 stands out for its reliable double-conversion online technology, scalability, and advanced monitoring capabilities. Its design prioritizes efficiency and adaptability, ensuring that organizations can maintain operational continuity and protect their critical systems against power disruptions. Whether in a data center or industrial setting, the GXT5000R-208 is a dependable UPS solution that meets the demanding requirements of modern power management.