B. CLEANING THE XRN
Use a clean,
Always disconnect the XRn’s power cords before cleaning. Resume operation only after the surfaces are completely dry.
C. PERFORMING A ROBOTIC SELF-TEST
To ensure that everything is working properly, a
•Load some discs into the Right Bin
•The cover must be closed for this operation to complete. However, in order to access the buttons you must open the cover. To get around this problem simulate closing the cover by activating the cover lock sensor. You may do this by putting an object such as a folded piece of paper in the slot where the lock would normally be located.
•With the unit turned on, press the Cartridge Button
•While holding the Cartridge Button, press the
Power Button until the robotics start to move.
•Release both buttons
•To stop the test, wait until the disc has moved to the Right Bin and press the Power Button.
42Maintenance and Troubleshooting