5.1.3.2 Advanced Setup

On the Advanced Setup screen you can set the following parameters:

Adapter’s Own I2C Slave Address

Select the I2C adapter’s own slave address. The adapter will acknowledge messages sent to this slave address. The default address is 0x6E.

General Call Enable

General Call Enable allows the I2C adapter to respond as a slave receiver to the I2C General Call Address (0x00). General Call is used by a master to broadcast an I2C message to multiple devices. The default value is enabled.

I2C Bus Master Bit Rate

Select I2C Bus speed during master operations. 100kHz is standard mode. 400kHz is fast mode. Available rates are I2C adapter dependant.

I2C Bus Time-Out

Specify how long the I2C adapter will wait before reporting an I2C Bus inter-byte time-out (0 = no time-out, 1 to 32767 milliseconds, iPort/AI fixed at 1 second).

Enable INT Signal Monitor (on supported adapters)

Enables monitoring of the INT signal state. INT state changes are reported in the main screen Communications Events window.

31

Image 37
Contents User’s Guide Introduction Page Table of Contents Page Page DLL/USB Page Page Page Page Page Page Page Page Page Part IPort Utility Pack For Windows V5.4 Page Page Page Page Page Page Page Page Page Page Page Message Center Command Line Arguments CLOCK12.5K Page Page Page Page Page Page Page Page Page Page Page Page Page Page IPort DLL/USB Revision Report Appendix a I2C Connector Information England