Black Box ACXCWDM4, ServSwitchTM CWDM Mux manual Quick Setup Guide

Page 7

Quick Setup Guide

Quick Setup Guide

This section briefly describes how to install your ServSwitch CWDM Mux system. Unless you are an experienced user, we recommend that you follow the full procedures described in the rest of this manual.

Install system

1.Install the ServSwitch CWDM Mux transceivers in the local and remote units. Each wavelength must not appear more than once in the system. Device pairs must carry transceivers with the same wavelength.

2.Connect interconnection cables from remote/local unit to the ServSwitch CWDM Mux—make sure you connect the transceivers to the matching port of the ServSwitch CWDM Mux. Be sure to use single-mode fiber cable between the local and remote units via the common link.

3.Power on the system.

Link established?

YES

 

 

 

Check the fiber cables and fiber connectors.

 

NO

Check whether the transceivers are plugged

 

 

into the correct ports. 1530-µm lightwave trans-

 

 

 

ceivers should plug into 1530-µm ports,

 

 

 

 

 

 

1550-µm transceivers should plug into 1550-µm

 

 

 

ports, and so on.

 

 

 

 

 

 

 

 

 

 

Done

724-746-5500 blackbox.com

Page 7

Image 7
Contents ServSwitch Cwdm Mux Trademarks Used in this Manual ServSwitch Cwdm MuxFCC and IC RFI Statements ServSwitch Cwdm Mux Safety Precautions and Installation Guidelines Safety Precautions and Installation GuidelinesTable of Contents Quick Setup Guide Quick Setup GuideSpecifications Overview Hardware Description Example of a ServSwitch Cwdm Mux SystemCompatibility Interconnection Cable Requirements InstallationSystem Setup DiagnosticsShipping and Packaging TroubleshootingTroubleshooting Problem/Solutions Contacting Black BoxAppendix A. Rackmount Options Appendix B. Glossary Appendix B GlossaryAbout Black Box Black Box Tech Support FREE! Live /7