3. Installation
For
3.1 Interconnection Cable Requirements
To connect the local and remote
•Fiber cable: Two strands of fiber are required for connecting the local and remote
CWDM Mux box and to interconnect both Mux/Demux boxes.
•Recommended cables:
•Maximum cable length: Approximately 25 miles (40 km).
3.2 System Setup
To install your ServSwitch CWDM Mux system:
1.Switch off all devices.
2.Install the ServSwitch CWDM Mux Transceivers in the local and remote CWDM Mux units. Each wavelength must not appear more than once in the system. Device pairs must carry transceivers with the same wavelength.
NOTES: Each wavelength (1530, 1550, 1570, 1590 nm) must not be used more than once at each side! For four links, use four different wavelengths; for three links, use three different wavelengths; and for two links, use two different wavelengths.
Each transceiver will work only at the appropriate port.
The data will always flow between devices with the same wavelengths.
3.Connect interconnection cables from the remote/local
4.Connect local and remote ServSwitch CWDM Mux units with matching interconnection cable
5.Power on the system.
3.3 Diagnostics
There are no diagnostics on the ServSwitch CWDM Mux. Please use the capabilities of the attached units.