ELECTRICAL SUPPLY CONNECTION

17

OPTIONAL BLOWER INSTALLATION

Models BK and BKT

ELECTRICAL SUPPLY CONNECTION

CAUTION: Disconnect the electrical power to the supply circuit before attempting to connect or service this appliance.

WARNING: This appliance, when installed must be electrically grounded in accordance with local code or in the absence of local code, with the current National Electric Code, ANSI/NFPA 70, or the Canadian Electric Code, CSA C22.1.

J-BOX

COVER w/

STRAIN RELIEF

ROMEX

CABLE

J-BOX COVER

J-BOX

COVER w/

STRAIN RELIEF

SCREW - TAB

RETAINER

J-BOX WITH

RECEPTACLE

A pre-wired junction box receptacle with strain relief is provided on the right side of the cabinet for hard wiring the unit to a 15 Amp, 120VAC, 60Hz grounded branch circuit. If the installation demands that the electrical supply be connected from the left side, the entire receptacle box can be relocated to the left side by following these instructions:

Note: If you do not need to relocate the junction box, to connect the electric supply follow steps 8 through 11 only:

1.Remove the 2 screws and outer cover with strain relief bushing on the right side of the cabinet (see Figure 32).

2.Removeinnerretainingscrew onthejunctionboxmountingtab.

3.Slide the junction box up until the screw mounting tab is lined up to the notch in the outer cabinet.

4.Swing the junction box out and slip the retaining flange out through the slot in the outer cabinet.

5.Remove the two screws and outer cover on the left side of the outer cabinet.

6.Reinsert the junction box retaining flange through the slot now on the left side and swing the screw mounting tab back through the notch as before.

7.Slide the junction box down till the mounting tab holes line up and replace the inner retaining screw.

8.With the junction box cover removed, pull the end of 3-wire Romex supply line through the universal strain relief bushing on the cover. (see Figure 32).

9.Strip back the outer Romex to about 4” and connect the black, white and green wires accordingly using 3 wire nut connectors.

10.Tuck the tailing wires into the junction box and replace the junction box cover using the 2 remaining screws.

11.Tighten down the strain adjustment on the universal bushing until the Romex sheathing is secured.

The electrical connection is now complete.

Figure 32 - Relocating Junction Box Receptacle and Electrical Supply Connection

OPTIONAL BLOWER INSTALLATION

NOTICE: If installing the blower in an existing fireplace with gas connections, shut off the gas supply to the fireplace before attempting to service this appliance. If it is necessary to disconnect the gas supply, contact a qualified service person to do this.

Model BK Installation

Follow all instructions provided in the blower accessory kit:

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 33).

2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 33). Tighten screws securely

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 33).

 

 

Blower

Lower Firebox

Location

 

Cavity

 

Magnetic Strips

Side View

 

 

 

Spade Terminals

 

Exhaust

 

Port

 

 

Green

Wire

 

Ground

Screw

 

 

Figure 33 - Blower Model BK

116035-01B

www.desatech.com

Page 17
Image 17
Desa P), (V) CD36T(N, (V) CD36R(N Electrical Supply Connection, Optional Blower Installation, Model BK Installation