Desa (V) CD36T(N Cleaning and Maintenance, Glass Door, Pilot and Burners, Logs, Venting System

Models: (V) CD36R(N P) (V) CD36T(N

1 48
Download 48 pages 32 Kb
Page 30
Image 30

30

CLEANING AND MAINTENANCE

Gass Door

Pilot and Burners

Logs

Venting System

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circulating air passages of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding mate rial, pet hair, etc.

GLASS DOOR

WARNING: Handle glass door panel with care. Do not strike, slam, or otherwise abuse glass. Do not operate fireplace with the glass door removed, cracked, or broken.

WARNING: Do not use abrasive cleaners as this may damage glass. Use a nonabrasive household glass cleaner to clean glass. Do not clean glass when hot.

Glass must be cleaned periodically. During start-up it is normal for condensation to form on the inside of the glass causing lint, dust, and other airborne particles to cling to the glass surface. During initial start-up a slight film may form on the glass due to paint curing. The glass should be cleaned several times with a non-ammonia, non- abrasive househol cleaner and warm water after the first two weeks of operation. Thereafter, clean the glass two or three times during each heating season, depending on the usage and circumstances present. Refer to Removing/Replacing Glass Door, on page 23 of this manual when removing glass door for cleaning.

WARNING: Only parts supplied by the manufac- turer should be used when replacing broken or dam- aged glass door panel (see Replacement Parts, page ##). This glass door panel is a complete unit. No substitute materials may be used.

CAUTION: Wear gloves and safety glasses while handling or removing broken glass. Do not remove if glass is hot. Keep children and pets away from glass.

If glass has been broken, carefully remove glass door (see Remov- ing/Replaceing Glass Door, page 24). Vacuum all glass pieces with a shop vac.

CAUTION: Do not vacumm if pieces are hot.

Use only the tempered glass door replacement intended for this fireplace (see Replacement Parts, page ## for detail on ordering). No substitutions may be made. See Removing/Replacing Glass Door, on page 24 for instructions for replaceing glass door.

WARNING: Do not operate fireplace with glass door removed, cracked, or broken.

PILOT AND BURNERS

Remove ember material before cleaning burners and replace

Burner and controls should be cleaned with compressed air to remove dust. dirt, or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint.

LOGS

If you remove logs for cleaning, refer to Installing Logs and Glowing Embers, page 25, to properly replace logs.

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace log(s) if broken. See Replacement Parts on page 36.

Replace ember material periodically as needed. See Replace- ment Parts on page 36.

VENTING SYSTEM

Conduct annual inspection of the venting system following these guidlines:

1.Check areas of venting system that are exposed to the weather corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced immediately by a qualified service person.

2.Remove the vent cap and shine a flashlight ito vent. Re- move any foreign material.

3.Check for evidence of excessive condensation. Continuous condensation can cause corrosion of caps, pipes, and fittings and can be caused by having excessive lateral runs, too many elbows, or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been distributed and loosened. Check mechanical supports such as wall straps for rigidity.

www.desatech.com

116035-01B

Page 30
Image 30
Desa (V) CD36T(N, (V) CD36R(N, P) Cleaning and Maintenance, Glass Door, Pilot and Burners, Logs, Venting System