OPTIONAL BLOWER INSTALLATION

Continued

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and thermal switch, and that the screw for the thermodisc bracket and green ground wire is tight.

5.Mount the speed control box by placing the plastic control shaft through the opening in switch bracket (see Figure 34, page 18) or the ignition module bracket (see Figure 35, page 18)

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise un- til it is tight against mounting plate. Place control knob pro- vided on shaft (see Figure 34 or 35, page 18).

7.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Also double check all wire leads and make sure wire rout- ing is not pinched or in a precarious position. Correct accordingly.

8.Turn on power to duplex outlet if previously turned off per the warning in column 1, page 17.

9.Plug in blower power cord to duplex outlet.

10.The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up. The blower speed can be adjusted by rotating the control knob. To turn off, turn knob fully counter- clockwise until it clicks off. If the blower is ON and has been running with the fireplace operating, the blower will continue to run for a short time after the fireplace has been turned off. As the thermal switch cools down, the blower shuts down automatically.

11.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 6” in front of the blower (see Figure 36, page 18).

Power Cord

White Wire

Thermal

Blue Wire Magnetic

Strips

Switch

 

Bracket

Air Flow

 

Direction

OPTIONAL BLOWER INSTALLATION (Cont.)

19

Models BK and BKT)

WiIRING DIAGRAMS

Blower Wiring Diagram

Millivolt Ignition Wiring Diagram

Electronic Ignition Wiring Diagram

WIRING DIAGRAMS

CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Variable

Fan Switch

Fan Switch

 

 

(N.O.)

Off 1

2

Black

 

On

 

110/115

 

Blue

V.A.C. Black

 

Blower

White

 

Motor

Green

Figure 38 - Blower Wiring Diagram for Thermostatic-Controlled Models

 

PILOT

 

MILLIVOLT WIRING SCHEME

 

BURNER

 

 

 

 

 

 

THERMO-

 

THERMOPILE

 

DO NOT

 

 

 

 

COUPLE

 

 

 

 

 

 

REPLACE FACTORY WIRING WITH 105°C

CONNECT

 

 

 

TO 120V

 

 

 

EQUIVALENT OR HIGHER RATING

 

 

 

 

 

 

 

EXTERNAL WIRING USE ONLY CLASS 2

 

 

 

 

THERMOSTAT WIRE 18 GA. RED/WHITE

 

TO PILOT

 

 

RED

 

 

SAFETY

PILOT SAFETY VALVE

 

 

 

VALVE

WHITE

 

 

 

 

 

 

 

LO

 

TH

 

 

 

ON

 

 

 

 

 

I

 

TP

 

 

 

FFO

 

 

 

 

P

 

 

 

 

INCOMING

 

 

TH/TP

WALL SWITCH

 

 

 

 

 

MAIN GAS

 

 

 

 

 

SUPPLY

 

 

 

 

 

Figure 39 - Millivolt Ignition Wiring Diagram

Pilot

Burner

Black

 

 

Wire

 

 

Phillips

 

 

Screw

 

 

Thermal Switch

Ring Terminal

 

 

on Green Wire

Air Flow Direction

 

 

 

 

Magnets

Route BKT

 

 

Blower Through

Thermodisc

 

This Area

 

 

Side View Firebox Bottom

Blower

Location

 

 

GAS VALVE

EV1

EV2

IGNITOR LEAD

ORANGE

RED

BLACK

BLACK

BLACK

BLUE

GREEN

SYNETEKCONTROLS MODELIS1070B

24VAC

 

 

RED TRANSFORMER

 

 

WHITE

 

 

BLACK

INC

BLUE

GROUND

 

 

 

120 VAC

Figure 37 - Blower Model BKT

Figure 40 - Electronic Ignition Wiring Diagram

116035-01B

www.desatech.com

Page 19
Image 19
Desa (V) CD36R(N, (V) CD36T(N, P) installation manual Wiring Diagrams, Millivolt Wiring Scheme