VENTING INSTALLATION

INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 28 through 31 show four different configurations for verti- cal termination.

 

Venting with Three 90° Elbows

Note: Install

Vertical (V)

Horizontal (H1) +

 

Horizontal (H2)

restrictor ring

 

into inner pipe

8' min.

5' max.

section prior to

10' min.

8' max.

attaching vent

12' min.

11' max.

termination cap.

14' min.

14' max.

 

 

16' min.

17' max.

 

18' min.

20' max.

 

40' max.

20' max.

90° Elbow

VENTING INSTALLATION INSTRUCTIONS

15

Installation for Vertical Termination (Cont.)

Note: Install restrictor ring into inner pipe section prior to attaching vent termination cap.

 

Venting with Two 90° Elbows

 

Vertical (V)

Horizontal H

90° Elbow

8' min.

6' max.

9' min.

8' max.

 

 

10' min.

10' max.

 

12' min.

14' max.

 

14' min.

18' max.

 

40' max.

20' max.

Figure 28 - Vertical Venting Configuration using Three 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

Figure 29 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

Note: Install restrictor ring into inner pipe section prior to attaching vent termination cap.

90° Elbow

Venting with Two 90° Elbows

Vertical (V1)

Horizontal (H)

8' min.

9' max.

9' min.

11' max.

10' min.

13' max.

12' min.

17' max.

14' min.

20' max.

Note: Vertical (V1) + Vertical (V2) = 40' max.

Max. Horizontal Above 14' Vertical = 20'

Figure 30 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination)

116035-01B

www.desatech.com

Page 15
Image 15