10 | VENTING INSTALLATION INSTRUCTIONS |
Installation Planning (Cont.) |
VENTING INSTALLATION
INSTRUCTIONS
Continued
6.Noncombustible Exterior Wall: Position the horizontal vent cap in the center of the 8 ½” round hole and attach to the exte- rior wall with four wood screws provided. Before attaching the vent cap to exterior wall, run a bead of
Combustible Exterior Wall: For vinyl siding, stucco or wood exteriors, a siding standoff may be installed between the vent cap and exterior wall. The siding standoff prevents excessive heat from damaging the siding materials. Siding material must be cut to accommodate standoff. Bolt the vent cap to the stand- off. Apply
7.Combustible Exterior Wall Only: Fit the outer and inner wall firestop into the wall before connecting horizontal run to vent cap (see Figure 15).
8.Carefully move fireplace, with vent assembly attached, toward wall and insert vent pipe into horizontal termination. The pipe overlap should be a minimum of 1 ¼”.
9.CombustibleExteriorWallOnly:Slidewallfirestopagainst interiorwallsurfaceandattachwithscrewsprovided(seeFigure 16). See Figure 17 for horizontal termination details.
10.Place fireplace into position and shim with noncombustible ma- terial, if needed. Nail or screw flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level, it will not work properly.
INNER WALL
FIRESTOP
VINYL
SIDING
STANDOFF
VENT
CAP
HOT
APPLY
MASTIC
TO ALL SIDES
SCREWS
Figure 14 - Installing Siding Standoff
INNER WALL
FIRESTOP
OUTER WALL
FIRESTOP
VENT
CAP
HOT
Figure 15 - Installing Outer Wall Firestop
VENT
CAP
SCREWS
HOT
INNER WALL
FIRESTOP
PIPE SECTION
Figure 13 - Installing Horizontal Vent Cap (Noncombustible)
VENT CAP
Figure 16 - Installing Inner Wall Firestop
www.desatech.com |