PRE-INSTALLATION PREPARATION

Clearances 5

Framing and Finishing

PRE-INSTALATION

PREPARATION

Continued

PACKAGING AND REMOVAL

The (V)CD36R/T direct vent gas fireplace heater is packaged with:

-one box containg a 4-log set located on the burner in the firebox.

-one bag containing the owner’s manual with installation

instructions, operator’s guide, and warranty information.

-one bag of glowing ember material.

-one bag of vermiculite hearth treatments.

Remove the shrinkwrap securing the 2 carton trays to the unit. Lift the top carton tray off and remove the four corner posts. Discard the bottom tray once the unit is moved into position.

Note: On rear vent models you must remove the fiberboard collar protector located on the rear collar before installing the fireplace and venting system. See Figure 4.

CLEARANCES

Minimum clearances to combustibles for the fireplace are as follows:

Back, and sides

0” (0 mm)

Perpendicular walls

12” (305 mm)

Floor

0” (0 mm)

Ceiling to louver opening

40” (1016 mm)

Front

36” (914 mm)

Top

0” (0 mm)

Vent Surfaces

1” (26 mm) (See venting instructions

 

for specifics on vent clearances.)

Mantel Clearances

(See - Mantel Clearances for specific

 

clearances to combustible mantels.)

Combustible material with a maximum thickness of 5/8” (16 mm) may be flush with the top and sides of the front face of the fireplace.

FRAMING AND FINISHING

Figure 5 shows typical framing of this fireplace. Figure 6 shows framing for corner installation. All minimum clearances must be met.

For overall unit dimensions, framing allowances, and vent collar locations, see Unit Dimensions, Figure 9 on page 6.

For available accessories for this fireplace, see Accessories on page

37.If you are using a seperate combustible mantel piece, refer to Figures 7 and 8 for proper height and clearances. You can install a noncombustible mantel at any height above the fireplace opening. Note: Non-combustible mantels may discolor!

FIBERBOARD

COLLAR PROTECTOR

Figure 4 - Removing Collar Protector (Rear Vent) Fireplace

2x - VERTICAL DOUBLE STUD

36"

(914 mm)

36 1/4" (921 mm)

14 3/4" (375 mm)

Figure 5 - Framing Clearances for Flush, Wall Installation

 

2 1/2" (63 mm)

THESE DIMENSIONS ALLOW

6 5/8" ( 168 mm)

MIN. 1" (26 mm)

FOR 1" OF CLEARANCE

 

AT THE SIDES AND BACK

TO CENTER

 

 

OF THE FIREPLACE

OF REAR VENT

 

14 3/4"

HOWEVER, 0" CLEARANCE

 

 

 

IS ALSO PERMITTED AT

 

 

ALL SIDES WHEN FRAMED

21" (533 mm)

 

 

TO CENTER OF

 

 

TOP VENT

 

 

28 5/8"

 

14 3/4"

(727 mm)

 

 

(375 mm)

 

 

 

 

TO NAILING

 

 

FLANGES

 

 

12 1/4"

 

 

(311 mm)

 

 

TO

 

56 3/4"

OPENING

 

 

 

(1441 mm)

 

Figure 6 - Framing Clearances for Corner Installation

116035-01B

www.desatech.com

Page 5
Image 5
Desa P), (V) CD36T(N, (V) CD36R(N installation manual PRE-INSTALATION Preparation, Clearances, Framing and Finishing