Black Box LR5100A-T, LR5200A-R2 manual Trademarks

Page 2

Speed — Ethernet: Series 5100: 10 Mbps, Series 5200 10/100 Mbps. WAN: V.35, V.11, V24, G.703: up to 2.048 Mbps aggregate, CSU/DSU (WAN): 56/64 Kbps; ISDN(WAN): 128 Kbps

Protocol — IP & IPX Multi-Protocol router capabilities; Protocol-independent MAC-layer bridging; SNMP terminal access

Indicators — (4) LEDs: Power, LAN, Link 1, Link 2

Connectors — V.35 module: DB25 female;

V.11 / X.21 module: DB15 female

V.24 / RS.232 module: DB25 female;

RS.442 / RS.530module: DB25 female;

G.703module: BNC female;

CSU/DSU module: RJ48S;

ISDN module: RJ45

Series 5100: 1 of 3 possible LAN connectors: BNC female Thinnet, RJ45 female 10BaseT, or DB15 female AUI; Series 5200 LAN connector: RJ45 female 10/100 BaseT

Console port DB25 female

Power — 100-250VAC, 50-60 Hz, 0.3-0.7 A (internal); IEC950 male connector

Size — Bridge/Routers: 2.5"H x 8"W x 14.5"D (6.5 x 20.5 x 37 cm);

WAN Interface Modules: 2”H x 2”W x 4”D (5.5 x 5.5 x 10.5 cm).

Weight — Bridge/Routers:11 lb. (4.9 kg);

INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement)

1.Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2.Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3.Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4.Todas las instrucciones de operación y uso deben ser seguidas.

5.El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.

6.El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.

7.El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8.Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.

9.El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10.El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u

otros aparatos (incluyendo amplificadores) que producen calor.

11.El aparato electico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.

12.Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

13.Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objectos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.

14.El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.

15.En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.

16.El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.

17.Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.

18.Servicio por personal calificado devera ser provisto cuando:

A:El cable de poder o el contacto ha sido dañado; u

B:Objectos han caído o líquido ha sido derramado dentro del aparato; o

C:El aparato ha sido expuesto a la lluvia; o

D:El aparato parece no operar normalmente o muestra un cambio en su desempeño; o

E:El aparato ha sido tirado o su cubierta ha sido dañada.

TRADEMARKS

IBM® is a registered trademark of International Business Machines Corporation. VT100™ and VT52™ are trademarks of Digital Equipment Corporation. Wyse® is a registered trademark of Wyse Technology.

Image 2
Contents Series 5000 Bridge/Router Trademarks Federal Communications Commission FCC Using This Manual Contents Introduction to Filtering Appendix D Interface Pinouts Contents Unpack the Router Select a SiteIdentify the Reset Switch Location of the Reset Hole on RouterIdentify the Connectors Connect to the ConsoleMake the Link Connections Power Up the Bridge/Router Managing the router Using the MenusConventions Option NameTelnet Login to Bridge/Router and Enter the Required ConfigurationPassword Setting the T1/E1Parameters Framed/unframed/SF/ESFAs specifed First channel Number number of channelsMandatory Configuration Isdn U Isdn S/T PPP IsdnIdentify the Status LEDs OffApplications Typical Applications & How to Configure Them Bridging and Routing Should You Bridge or Route? Bridging Networks Bridged across a WAN linkIP Routing IP Address / Size of Subnet MaskIP Addressing Masks IP SubnetsDefining an IP Subnet Mask IP Default Gateway IP Static RouteIPX Routing Novell Servers in Both LocationsNovell Servers in One Location Only IPX Routed Local Area Networks Servers on one sideRAW 802.3 Frames IPX RoutingEthernet-II Frames Ieee 802.2 FramesSelect LAN1 or LAN2 Novell Server with Dual LANsIPX Forwarding Numbered Links PPP Link ConfigurationPPP Overview Link IP addressUnnumbered Links Peer IP addressEnabled Multilink OperationBasic WAN Configurations Basic Isdn ConnectionsSwitch Type Directory NumberSoft Reset PPP Isdn Manual Call Quick Connections Manual Call IP Address / Subnet mask sizeBasic Frame Relay Configuration Frame Relay configurationAuto Learning the Frame Relay Configuration Link SpeedManual Configuration LMI Type LMI TypeQuick Start Frame Relay IP Address / mask sizeQuick Start PPP Leased Line Connections Basic Leased Line ConfigurationDisabled Bridge Connection Configure Remote Site Profiles Configure Remote Site Profiles for Isdn PPP Isdn NumberEnabled Configure Remote Site Profile for Frame Relay Remote Site AliasPrimary Link CIREIR Configure Remote Site Profiles for Leased Line PPP Primary Link Number Recovery ScheduleServer Advanced FeaturesConfigure Dynamic Host Configuration Protocol IP Address / number of addressesIP address local DNS server ÄSecondary DNSEnter the private network IP address of each service offered Network Address Translation and Port Translation11 Napt Configuration Security Level Configure PPP SecuritySecurity Incoming Chap Secret Outgoing Chap Secret Incoming PAP PasswordOutgoing PAP Password Configure Firewall 13 Sample Firewall ApplicationID# 1 for ISP remote site Enter ID# 1 for ISP remote siteInbound FTP ServerDestination Mask Filter ID #Destination Address Source AddressFilters CompressionNetwork Address Translation Local or partner EnableBandwidth On Demand Introduction to Filtering MAC Address FilteringPattern Filtering NotBridge NetBIOS &NetBEUI Windows For WorkgroupsPopular Filters IP & Related TrafficBanyan NetBIOS over TCPIP Router Other interesting TCP PortsAppendix a Menu Trees Menu Tree Menu Tree Page Appendix B Octet Locations on Ethernet Frames Octet Locations on a Bridged TCP/IP FrameOctet Locations Configuration Pages Octet Locations on a Bridged XNS Frame Appendix C Servicing Information Opening the caseIdentifying the Internal Components Figure C-1 Top Internal View of the Ethernet Bridge/RouterSelecting MDI or MDI-X LAN Interface To Clear a Lost PasswordChanging LAN or WAN Interfaces Installing the Isdn Link Modules Processor settings for the Isdn Link ModulesConnecting to the ISDN-U Link Module Changing the Termination Straps on the Isdn S/T InterfacePerforming a Software Upgrade PC used for Tftp transfers Router a Router B Router C Servicing Information ATL-CSU/DSU Link Module Information Pinout InformationLink Clocking Information Interface Pinouts Console Pinouts DB25 Female DCE24 & RS232C Link Pinouts DB25 Female DTE11/X.21 Link Pinouts DB15 Female DTERS442 & RS530 Link Pinouts Figure D-7 RS530 Link PinoutsLink Pinouts DCERS232 Null-Modem Cable Configuration Figure D-9 RS232 Null-Modem CableNull-Modem Cable Configuration Figure D 10 V-35 Null-Modem CableRS530 Null-Modem Cable Configuration Figure D-11 RS530 Null-Modem CableRS530 To RS449 Conversion Cable DB25 Male DB37 MALE/FEMALE11/X.21 Null-Modem Cable Configuration Figure D-13 V.11/X.21 Null-Modem Cable

LR5200A-R2, LR5100A-T specifications

The Black Box LR5100A-T and LR5200A-R2 are advanced network media converters designed to facilitate seamless data transmission across various media types. These devices are particularly valuable for organizations seeking high-performance solutions for extending network communications beyond traditional limits.

The LR5100A-T is an Ethernet media converter that operates over twisted pair cabling, efficiently converting 10/100/1000 Mbps Ethernet signals into fiber optic signals. This capability allows businesses to harness the long-distance advantages of fiber optics while maintaining compatibility with existing Ethernet infrastructure. With a broad range of supported distances, users can effectively communicate over distances up to 100 kilometers, depending on the type of fiber optic cable used and the transmission rate.

In contrast, the LR5200A-R2 emphasizes compatibility with a wider range of fiber types and supports both multimode and single-mode fiber connections. It also provides auto-negotiation capabilities, which enable it to automatically detect and configure to the optimal speed of connected devices, streamlining setup and enhancing user experience.

One of the key features of both the LR5100A-T and LR5200A-R2 is their rugged design, making them suitable for deployment in harsh environments. They are engineered to withstand extreme temperatures and are resistant to vibration, ensuring reliability in challenging settings. Additionally, both models adhere to industry standards, ensuring interoperability with a diverse array of networking equipment.

Notably, these converters come equipped with LED indicators that allow for real-time monitoring of device status, simplifying network management and troubleshooting. This feature ensures that technicians are promptly alerted to any connectivity issues, significantly reducing downtime.

Powering options for both models include standard AC power supplies or Power over Ethernet (PoE), allowing for flexible deployment scenarios without the need for additional power outlets. This flexibility can be a crucial factor in environments where power availability may be limited.

With their blend of performance, durability, and advanced features, the Black Box LR5100A-T and LR5200A-R2 media converters represent a solid choice for organizations looking to future-proof their network infrastructure while ensuring high levels of connectivity and reliability. Whether extending existing networks or implementing new solutions, these devices provide the necessary tools for effective communication in today’s digital world.