Black Box LR5200A-R2, LR5100A-T manual Configure Remote Site Profiles

Page 47

Applications

Configure Remote Site Profiles

Remote Site Profiles allow the router to have different sets of configuration parameters for each of the remote site routers that may be called or that may call this router. This allows complete control over the configuration of each possible connection.

Each remote site profile is assigned an identification number when it is created, whether it is created automatically under auto-learning or manually by the user editing the remote site profile. The remote site is also named with an alias, which provides a more descriptive identifier for the remote site profile. For example, a remote site profile may be created with a name that describes the location of the remote router or a user name on an incoming connection. The alias may be up to 16 characters long and must begin with an alphabetic character (blanks and the character ”!” are not allowed).

There can be up to 128 remote site profiles. The ID numbers are assigned automatically in ascending order as the site profiles are created.

ID numbers 129, 130 and 131 are templates for creating remote site profiles with ISDN. Frame Relay or Leased Line connections respectively. A template may have its parameters set to match common network configurations and then be used to quickly set-up a new site. In addition to the reserved templates, you can use any remote site as a template to create a new site.

The remote site profile allows the definition of various connection parameters: Circuit set- up, Bridge and Routing protocol configuration, activation criteria and security.

The following steps must be performed on the router in order to define a new remote site profile.

7

Remote Site Profile ID & Alias

 

 

Location: Main

 

Ä Configuration

 

Ä WAN Set up

 

Ä Remote Site Set-up

 

Ä Edit Remote Site

 

The remote site alias must be entered. The remote site profile is then

 

created, an ID number is automatically assigned to it and the remote site

 

profile is opened for editing. If a remote site profile already exists, either

 

the ID number or the alias may be provided to access the site profile for

 

editing.

39

Image 47
Contents Series 5000 Bridge/Router Trademarks Federal Communications Commission FCC Using This Manual Contents Introduction to Filtering Appendix D Interface Pinouts Contents Select a Site Unpack the RouterLocation of the Reset Hole on Router Identify the Reset SwitchConnect to the Console Identify the ConnectorsMake the Link Connections Managing the router Using the Menus Power Up the Bridge/RouterOption Name ConventionsTelnet Login to Bridge/Router and Enter the Required ConfigurationPassword Framed/unframed/SF/ESF Setting the T1/E1ParametersFirst channel Number number of channels As specifedIsdn U Isdn S/T PPP Isdn Mandatory ConfigurationOff Identify the Status LEDsApplications Typical Applications & How to Configure Them Bridging and Routing Should You Bridge or Route? Networks Bridged across a WAN link BridgingIP Address / Size of Subnet Mask IP RoutingIP Addressing IP Subnets MasksDefining an IP Subnet Mask IP Static Route IP Default GatewayNovell Servers in Both Locations IPX RoutingIPX Routed Local Area Networks Servers on one side Novell Servers in One Location OnlyIeee 802.2 Frames IPX RoutingEthernet-II Frames RAW 802.3 FramesSelect LAN1 or LAN2 Novell Server with Dual LANsIPX Forwarding Link IP address PPP Link ConfigurationPPP Overview Numbered LinksPeer IP address Unnumbered LinksMultilink Operation EnabledBasic Isdn Connections Basic WAN ConfigurationsDirectory Number Switch TypeSoft Reset PPP Isdn Manual Call Quick Connections IP Address / Subnet mask size Manual CallFrame Relay configuration Basic Frame Relay ConfigurationLink Speed Auto Learning the Frame Relay ConfigurationLMI Type Manual Configuration LMI TypeIP Address / mask size Quick Start Frame RelayQuick Start PPP Leased Line Connections Basic Leased Line ConfigurationDisabled Bridge Connection Configure Remote Site Profiles Isdn Number Configure Remote Site Profiles for Isdn PPPEnabled Remote Site Alias Configure Remote Site Profile for Frame RelayCIR Primary LinkEIR Configure Remote Site Profiles for Leased Line PPP Primary Link Number Schedule RecoveryIP Address / number of addresses Advanced FeaturesConfigure Dynamic Host Configuration Protocol ServerÄSecondary DNS IP address local DNS serverNetwork Address Translation and Port Translation Enter the private network IP address of each service offered11 Napt Configuration Security Level Configure PPP SecuritySecurity Incoming Chap Secret Outgoing Chap Secret Incoming PAP PasswordOutgoing PAP Password 13 Sample Firewall Application Configure FirewallFTP Server Enter ID# 1 for ISP remote siteInbound ID# 1 for ISP remote siteSource Address Filter ID #Destination Address Destination MaskFilters CompressionNetwork Address Translation Local or partner EnableBandwidth On Demand MAC Address Filtering Introduction to FilteringNot Pattern FilteringIP & Related Traffic NetBIOS &NetBEUI Windows For WorkgroupsPopular Filters BridgeOther interesting TCP Ports NetBIOS over TCPIP Router BanyanAppendix a Menu Trees Menu Tree Menu Tree Page Octet Locations on a Bridged TCP/IP Frame Appendix B Octet Locations on Ethernet FramesOctet Locations Configuration Pages Octet Locations on a Bridged XNS Frame Opening the case Appendix C Servicing InformationFigure C-1 Top Internal View of the Ethernet Bridge/Router Identifying the Internal ComponentsSelecting MDI or MDI-X LAN Interface To Clear a Lost PasswordChanging LAN or WAN Interfaces Processor settings for the Isdn Link Modules Installing the Isdn Link ModulesChanging the Termination Straps on the Isdn S/T Interface Connecting to the ISDN-U Link ModulePerforming a Software Upgrade PC used for Tftp transfers Router a Router B Router C Servicing Information ATL-CSU/DSU Link Module Information Pinout InformationLink Clocking Information Interface Pinouts DB25 Female DCE Console PinoutsDB25 Female DTE 24 & RS232C Link PinoutsDB15 Female DTE 11/X.21 Link PinoutsFigure D-7 RS530 Link Pinouts RS442 & RS530 Link PinoutsDCE Link PinoutsFigure D-9 RS232 Null-Modem Cable RS232 Null-Modem Cable ConfigurationFigure D 10 V-35 Null-Modem Cable Null-Modem Cable ConfigurationFigure D-11 RS530 Null-Modem Cable RS530 Null-Modem Cable ConfigurationDB25 Male DB37 MALE/FEMALE RS530 To RS449 Conversion CableFigure D-13 V.11/X.21 Null-Modem Cable 11/X.21 Null-Modem Cable Configuration

LR5200A-R2, LR5100A-T specifications

The Black Box LR5100A-T and LR5200A-R2 are advanced network media converters designed to facilitate seamless data transmission across various media types. These devices are particularly valuable for organizations seeking high-performance solutions for extending network communications beyond traditional limits.

The LR5100A-T is an Ethernet media converter that operates over twisted pair cabling, efficiently converting 10/100/1000 Mbps Ethernet signals into fiber optic signals. This capability allows businesses to harness the long-distance advantages of fiber optics while maintaining compatibility with existing Ethernet infrastructure. With a broad range of supported distances, users can effectively communicate over distances up to 100 kilometers, depending on the type of fiber optic cable used and the transmission rate.

In contrast, the LR5200A-R2 emphasizes compatibility with a wider range of fiber types and supports both multimode and single-mode fiber connections. It also provides auto-negotiation capabilities, which enable it to automatically detect and configure to the optimal speed of connected devices, streamlining setup and enhancing user experience.

One of the key features of both the LR5100A-T and LR5200A-R2 is their rugged design, making them suitable for deployment in harsh environments. They are engineered to withstand extreme temperatures and are resistant to vibration, ensuring reliability in challenging settings. Additionally, both models adhere to industry standards, ensuring interoperability with a diverse array of networking equipment.

Notably, these converters come equipped with LED indicators that allow for real-time monitoring of device status, simplifying network management and troubleshooting. This feature ensures that technicians are promptly alerted to any connectivity issues, significantly reducing downtime.

Powering options for both models include standard AC power supplies or Power over Ethernet (PoE), allowing for flexible deployment scenarios without the need for additional power outlets. This flexibility can be a crucial factor in environments where power availability may be limited.

With their blend of performance, durability, and advanced features, the Black Box LR5100A-T and LR5200A-R2 media converters represent a solid choice for organizations looking to future-proof their network infrastructure while ensuring high levels of connectivity and reliability. Whether extending existing networks or implementing new solutions, these devices provide the necessary tools for effective communication in today’s digital world.