Chapter 6: Operation
NOTE: If the far end of the cable is connected to any device it will notify you to check the far end of the cable. When ready to proceed, press (q TEST).
Error Messages: If there is a problem that stops the test from proceeding, one of the following error messages will be displayed:
CABLE IS ACTIVE: There is an active network port on the far end of the cable. You will need to unplug it to proceed.
CHECK CABLE END: A voltage is present on one or more of the cable pairs or the REMOTE PROBE is connected to the cable end when it is not needed. You will need to unplug it to proceed.
NO CABLE: There is no cable connected or an inactive port is plugged into the far end of the cable. Plug in the cable or disconnect the inactive port.
Figure 6-37. Testing progress is displayed.
Cable testing has commenced. You can follow its progress
on the display. During this phase of testing, information about length, opens, shorts, and split pairs is being gathered and computed. If any cabling errors are encountered, you will be alerted including the distance to any problems.