IBM RS/6000 SP manual Utility Runs on Description Directory FaultserviceWormRTGCS, Usr/lpp/ssp/css

Page 60

Table 3-1. Service procedure tools

Utility

Runs on

Description

 

Directory

 

 

 

 

 

fault_service_Worm_RTG_CS

All nodes

Monitors the switch for faults. It

 

/usr/lpp/ssp/css

 

 

restarts the switch if a fault is

 

 

 

 

detected.

 

 

 

 

 

 

 

css.snap

All nodes,

Collects log, trace, and dump

 

/usr/lpp/ssp/css

 

CWS

information created by SP Switch2

 

 

 

 

support code (device driver, worm,

 

 

 

 

fault-service daemon, diagnostics)

 

 

 

 

 

 

 

rc.switch

All nodes

Starts the daemons and IP

 

/usr/lpp/ssp/css

 

 

configuration tools.

 

Note: When working with a

 

 

 

 

two-plane SP Switch2

 

 

 

 

system, add the adapter

 

 

 

 

name to the command, as

 

 

 

 

follows:

 

 

 

 

/usr/lpp/ssp/css/rc.switch

 

 

 

 

-a<adapter_name>

 

 

 

 

 

Estart

Primary or

Tunes the switch and puts in into run

 

/usr/lpp/ssp/bin

 

Control

phase. Also, kicks off the route table

 

 

 

Node

generator and distributes the routes

 

 

 

 

to the nodes, by placing them in the

 

 

 

 

etc/SP directory on the control node.

 

 

 

 

 

 

 

Eprimary

All nodes

Sets a node as the primary node.

 

/usr/lpp/ssp/bin

 

 

 

 

 

Etopology

All nodes

Stores switch topology information in

 

/usr/lpp/ssp/bin

 

 

the System Data Repository for a

 

 

 

 

node or a series of nodes. Also

 

 

 

 

retrieves a topology files out of the

 

 

 

 

SDR.

 

 

 

 

 

 

 

ifconfig

All nodes

This sets up the IP interface to the

 

NA

 

 

switch.

 

(AIX command)

 

 

 

 

 

 

 

 

 

Table 3-2. Setup output files

 

 

 

 

 

 

 

 

File

Location

Description

Directory

 

 

 

 

rc.switch.log

All nodes

Logs all information on the last run

/var/adm/SPlogs/css

 

 

of rc.switch. It will indicate if this is

 

 

 

 

a primary or secondary node, the

 

 

 

 

associated switch chip information,

 

 

 

 

and IP address information.

 

 

 

 

 

 

rc.switch.log.previous

All nodes

A copy the previous run of

/var/adm/SPlogs/css

 

 

rc.switch.

 

 

 

 

 

 

expected.top.xnsb.yisb.0

All nodes

Used by rc.switch to more easily

/etc/SP/

 

 

parse out chip connection

 

 

 

 

information.

 

 

 

 

Where:

 

 

 

 

x = the number of the node switch

 

 

 

 

board

 

 

 

 

y = the number of the intermediate

 

 

 

 

switch board

 

 

 

 

 

 

fs_daemon_print.file

All nodes

A log of the daemon

/var/adm/SPlogs/css0/p0

 

 

 

 

 

3-2RS/6000 SP: SP Switch2 Service Guide

Image 60
Contents IBM Page IBM Fourth edition April Contents FRU removals and replacements Figures Vi RS/6000 SP SP Switch2 Service Guide Tables Viii RS/6000 SP SP Switch2 Service Guide Safety and environmental notices Safety notices in EnglishRS/6000 SP SP Switch2 Service Guide SPSFD017 Xii RS/6000 SP SP Switch2 Service Guide Laser safety information Environmental notices Product recycling and disposalXiv RS/6000 SP SP Switch2 Service Guide About this book Who should use this bookRelated information How to use this book How to send your commentsUsers responsibilities Maintenance Analysis Procedures MAPs Switch MAPsSwitch description and problem determination MAP Purpose of this MAPSwitch Connection Types Standard Node Switch-to-SwitchSwitch Assembly Description SP Switch2 SP Switch2 Assembly High-Level Diagram Green Power LED Yellow Environment LEDFlashing Errpt -a -N sphwlog pg Errpt -a -N css0 Errpt -a -N WormSP Switch2 Wrap Plugs Priority Message or condition ActionSwitch supervisor communications MAP Green LED Yellow LED IndicationTogether Switch supervisor communications MAP Switch supervisor communications MAP Switch environment MAP Condition ActionPriority Component Action SP Switch2 Chassis Assembly Power supply failure diagnostics Switch power MAP Switch power MAP Step 16RS/6000 SP SP Switch2 Service Guide Switch function MAP EstartEprimary Splstdata -n pgPg /var/adm/SPlogs/css0/p0/out.top Notes Switch Function MAP Error # Device Message Link Message Description and Action Starts the faultserviceWormRTGCS daemonVar/adm/SPlogs/css0/p0/out.top file on the primary If the cabling does not match, correct the cabling E02-S17-BH-J18 E02-N05E06-S02-BH-J3 Priority Condition ActionStep Service Request NumberFailing Component Description SRN Priority Failing Component Action26RS/6000 SP SP Switch2 Service Guide Dsh -w nodelist /usr/lpp/ssp/css/rc.switch Dsh -a /usr/lpp/ssp/css/rc.switch Locations Naming standard for RS/6000 SP componentsFormat structure Location diagrams of the RS/6000 SP components Major assemblyFront and rear views of RS/6000 SP frame Figure notes2shows a front view of the RS/6000 SP multi-switch frame Frame locations Frame FRAExample E01-FRA-G1 Switch assembly locations Connector detailsCable routing Locations Cable routing in a multi-switch frame F/C Switch data cables Cable Part Plug from Plug to Number Location12RS/6000 SP SP Switch2 Service Guide Service procedures Personal ESD requirementsTools and files overview Utility Runs on Description Directory FaultserviceWormRTGCS Rc.switchUsr/lpp/ssp/css/rc.switch IfconfigUsing the css.snap script Var/adm/SPlogs/cssX where X=0 or Var/adm/SPlogs/cssX/p0 where X=0 orCss.snap file structure Var/adm/SPlogs/cssMost recent css.snaps ifcldump Most recent css.snaps readregsMost recent css.snaps splstdata SP Switch2 supervisor self-test Css.snap file package namesDisk space handling If the -a and -p flags are not usedSwitch supervisor status verification using Perspectives Opening a switch paneChecking switch status Self-test ConditionsUpdating the SP Switch2 supervisor code Base code verificationRemoving and restoring switch resources Removing an SP Switch2 from the active configurationRestoring an SP Switch2 to the active configuration Efence of primary and primary backup nodes Fencing nodesReplacing an SP Switch2 from service position Resetting the clock and bootlist after servicing a nodeRunning diagnostics on a switch port FRU removals and replacements Handling static-sensitive devicesSP Switch2 service procedures Removing a fan assemblyReplacing a fan assembly Removing a power supply Replacing a power supplyRemoving the LED bracket assembly Replacing the LED bracket assemblyRemoving the switch supervisor card Replacing the switch supervisor card Removing an interposer cardRemoving the switch planar Replacing an interposer cardReplacing the switch planar Removing the 48 V dc circuit breaker assemblyReplacing the 48 V dc circuit breaker assembly Removing the LED power extension cableReplacing the LED power extension cable Parts catalog SP Switch2 assembly view Assembly Part number Units Description Index 4RS/6000 SP SP Switch2 Service Guide Baffle, Power Supply Bay Tray Switch cables This page intentionally left blankSwitch cables SP Switch2 Frame F/C FrontSP Switch2 Frame F/C 2032 frame extender F/C 2032 frame extender SP Switch2 Frame Model 556 and F/C SP Switch2 Frame Model 556 and F/C Model 556 and F/C 2034 frame extender Model 556 and F/C 2034 frame extender 16RS/6000 SP SP Switch2 Service Guide Trademarks AIXUnited Kingdom telecommunications safety requirements European Union EU statementIndustry Canada compliance statement For installations in Japan Electromagnetic interference EMI statement TaiwanRadio protection for Germany 4RS/6000 SP SP Switch2 Service Guide Index Numerics Files Created by css.snap Removing LED bracket 4RS/6000 SP SP Switch2 Service Guide Readers comments ± Wed like to hear from you How satisfied are you that the information in this book isPlease tell us how we can improve this book Business Reply Mail Page Ibmr
Related manuals
Manual 114 pages 42.66 Kb

RS/6000 SP specifications

The IBM RS/6000 SP (Scalable Power) is a high-performance computing system that was developed in the early 1990s and has since become a significant player in the realm of supercomputing and enterprise solutions. Designed primarily for scientific, engineering, and complex data analysis tasks, the RS/6000 SP provides powerful processing capabilities, enhanced scalability, and features to support demanding applications.

One of the key characteristics of the RS/6000 SP is its modular architecture, which allows for the addition of multiple nodes. Each node is based on IBM's Power architecture, leveraging the RISC (Reduced Instruction Set Computing) design to achieve high throughput and efficiency. The system can support configurations ranging from a few nodes to hundreds, enabling organizations to scale their computational power as needed based on workload requirements.

The RS/6000 SP employs advanced interconnect technologies, most notably the SP Switch, which ensures high-speed communication between nodes. This interconnect allows for seamless data transfer, ensuring that the system can handle large datasets and complex computations without bottlenecks. The SP's ability to deliver concurrent processing capabilities makes it ideal for parallel computing tasks, including simulations, modeling, and large-scale computations.

In terms of software, the RS/6000 SP was equipped with AIX, IBM's version of the UNIX operating system, which provides a stable and secure environment for enterprise applications. Furthermore, the system supports a vast array of programming languages and tools, including Fortran, C, and C++, along with libraries and frameworks designed for high-performance computing. This compatibility allows developers to optimize their applications to fully utilize the underlying hardware.

Another notable feature of the RS/6000 SP is its extensive support for various workloads, including database management, multi-user applications, and graphical processing. The system was equipped with high-performance graphics capabilities, making it suitable for tasks that require intensive visualization, such as computer-aided design (CAD) and scientific visualization.

Overall, the IBM RS/6000 SP has solidified its role in the high-performance computing landscape, combining advanced technologies, robust scalability, and flexibility to meet the unique demands of research and enterprise environments. Its legacy continues to influence modern computing architectures, embodying IBM’s commitment to innovation and performance in the pursuit of complex problem-solving capabilities.