CX208/212 Programming Guide
Set RS232 Parameters
Command Structure <ESC>CRaaaaa,b,c,d
aaaaa = Baud Rate (2400, 4800, 9600,19200 or 38400)
b= Parity (N for None, O for Odd, E for Even)
c= Number of data bits (7 or 8)
d= Number of stop bits (1 or 2)
Example: ESC>CR9600,N,8,1
| Placement: | Must be sent in a separate data stream. |
| Default: | 9600,N,8,1 |
Command Function | To select the desired RS232 communications settings | |
Input to Printer | <ESC>AZCR9600,N,8,1 | |
Printer Output | There is no printer output as a result of this command. | |
Special Notes | 1. Any commands sent to the printer over the RS232 port within two | |
| seconds of receiving this command may be lost. |
2. The RS232 settings must match those of the host system. If the RS232 settings are unknown, printing a Self Test label will list the current printer settings.
Page 97 | PN 9001092 Rev. A | SATO CX208/212 Printers |