Dimplex DF2622SS Maintenance, Light Bulb Replacement, Operation, Lower Light Bulb Requirements

Models: DF2622BLK DF2622SS NBDF2608

1 20
Download 20 pages 23.54 Kb
Page 13
Image 13
 Maintenance

Light Bulb Replacement Operation

ON button located on the remote control transmitter.

!NOTE: You will have only 10 seconds to perform this last step. Failure to do so will result in these steps needing to be followed again.

This will synchronize the remote control transmitter and receiver.

Figure 6

Lower Light Bulb RequirementsOFF

Button

ON

Button

Battery

Cover

Do not exceed 60 Watts per bulb. Maintenance

WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.

Light Bulb Replacement

Allow at least five (5) minutes for the light bulbs to cool before touching them to avoid accidental burning of the skin. The light bulbs need to be replaced when you notice a dark section of

the flame or when the clarity and detail of the log ember bed exterior reduces. There are three (3) bulbs under the Log Set Assembly, which generate the

flames and embers, and two (2) bulbs above that illuminate the log exterior.

Lower Light Bulb Requirements

Quantity of three (3) clear chan- delier or candelabra bulbs with an E-12 (small) socket base, 60 Watt rating. Example: GE 60BC or Philips 60CTC.

Do not exceed 60 Watts per bulb.

Helpful Hints

It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce