PARTS REPLACEMENT
| 
 | 
 | 1 | 
| 5 | 
 | 6 | 
| 
 | 7 | 
 | 
| 4 | 8 | 8 | 
| 
 | ||
| 8 | 
 | 9 | 
| 
 | 
 | |
| A | 
 | 
 | 
| 0 | 
 | 
 | 
| 
 | 
 | 2 | 
| 2 | 
 | 3 | 
| 
 | 1 | 
 | 
5.Power Unit
(1)Disconnect the power cord from the AC outlet.
(2)Remove:
∙Upper casing unit (See 1. above.)
∙Three screws (See 4. above.)
∙Interface PCB (See 4. above.)
∙Screw 1
∙Four screws 2
∙Lower casing chassis 3
∙Connector 4
∙Two tapping screws 5
∙Shield chassis (A) 6
∙Connector 7
∙Four screws 8
∙Power unit 9
∙Screw 0
∙Earth plate (A) A
6.Fuse
(1)Remove shield chassis A, according to procedure given in 5. above.
(2)Check fuse F1. 1
If the fuse is blown, replace with the following.
| AC Voltage | F1 | 
| 
 | 
 | 
| 120V | |
| 
 | 
 | 
| EAK3.15A250V | |
| 
 | 
 | 
If the replacement fuse also blows out, replace the power unit or check the main logic board.