10.OPTIONS

You can also use 1.75 inch (44.5 mm) width roll paper by removing the paper guide B and attaching the optional guide C.

(1)Removing the Paper Guide B

Spread the boss unit on both sides of the paper guide B and remove the the boss from the paper guide A side. Rotate the paper guide B and remove it.

(2)Setting the Paper Guide C

When you remove the paper guide B, you can see the groove at the right side of the paper guide A. Insert the paper guide C into that groove.

Fig. 10-1 Paper Guide Option

– 38 –

Image 41
Contents MP111MP-24G-A MP115MP-24G-A Page Contents General Description Construction ConfigurationOther Principle of OperationMP111MP External view MP115MP External view Details of Character Dimentions General SpecificationsPrinting Specifications Paper spec. & Print area Paper SpecificationsMP111 Ink Ribbon SpecificationsMP115 CR Motor + CMN VH Connector SpecificationsConnector connections Half font Forward printing Print TimingPrinting Timing ChartRelease action Transistor’s turn off delay time td 2 ∝ s Print Head SpecificationsTR1 Number of character per line Dot/chara 13 Print duty specific wires 14 Current waveform of the motor CR Motor SpecificationsTR2 16 Drive circuit of paper feed motor example Paper Feed Motor SpecificationsMP115MP only Ribbon Shift Solenoid RS-SOL Specifications19 Circuit of timing signal 1 example Timing Signal Detector SpecificationsPaper-out Detector PE-sig Specifications Home Position Detector HP-sig SpecificationsDimension and Weight Ribbon Position Detector RS-sig Specifications MP115MP only24 MP111MP External dimension unit mm 25 MP115MP External dimension unit mm Reliability Specifications Setting the Ribbon Cartridge Removing the Paper Setting the PaperSetting the Paper SP2 InstallationInstallation space example unit mm Printer installation example unit mm Page Printer installation Operational Notes Power ON/OFF NoteOther Notes Carriage Motor Protection Method Against Mechanical Errors5 V Line Power Supply Capacity24 V Line Paper Guide Option OptionsDistributed by