3.12 Home Position Detector (HP-sig) Specifications
The home position detector is composed of the mechanical switch. While the carriage is located at the left end, the switch remains ON.
R1 | 10 kΩ |
|
|
R2 | 15 kΩ |
|
|
C1 | 0.022 ∝ F |
|
|
Fig. 3-21 Home position detector circuit (example)
In order to improve reliability, we recommend that the HP-sig is detected as described below.
(1)When the T1-sig is unstable when turning on the power, etc.
Detect the L level after having detected the H level of the HP-sig, and then, after having carried out 81 pulse counts for the T1-sig, detect the H level.
(2)When the T1-sig is decided during continuous operation of the motor
Detect the L level of the HP-sig, and then, after having counted 847 pulses of the T1-sig, detect the H level.
3.13 Paper-out Detector (PE-sig) Specifications
The
R1 | 10 kΩ |
|
|
R2 | 15 kΩ |
|
|
C1 | 0.022 ∝ F |
|
|
Fig. 3-22 Paper-out detector circuit (example)