Star Micronics MP115MP-24G-A, MP111MP-24G-A operation manual Operational Notes, Power ON/OFF Note

Page 38

8. OPERATIONAL NOTES

8.1 Power ON/OFF Note

If the 5 V power supply line for logic has not fully risen or fallen immediately after the power supply is turned ON or OFF, the CPU or TTL in the logic circuit may misoperate. At such times, power is supplied to the motor or solenoid, causing, in the worst case, burnt out solenoid or running of motor (misoperation), unless the 24 V power supply line for motor drive is completely OFF. To avoid such misoperation, take into account the following points.

8.1.1 Power supply ON/OFF timing rule

Supply 24 V line after the 5 V line has fully risen. Similarly, cut off the 5 V line after the 24 V line has fully fallen.

Fig. 8-1 Power supply ON/OFF timing rule

8.1.2 Method of controlling the drive circuit

Fig. 8-2 Drive circuit controlling method

If the power supply ON/OFF timing rule cannot be followed, reset the print solenoid or motor drive circuit with control signal. An example of this type of circuit is shown in Fig. 8-3. Turn OFF transistor TR1, while the 5 V line has not completely risen, in order to inhibit power to the print solenoid. Then as soon as the 5 V line has completely risen, turn ON TR1, permitting power to the print solenoid.

– 35 –

Image 38
Contents MP111MP-24G-A MP115MP-24G-A Page Contents General Description Other ConfigurationConstruction Principle of OperationMP111MP External view MP115MP External view Details of Character Dimentions General SpecificationsPrinting Specifications Paper Specifications Paper spec. & Print areaInk Ribbon Specifications MP111MP115 Connector Specifications CR Motor + CMN VHConnector connections Print Timing Half font Forward printingTiming Chart PrintingRelease action Print Head Specifications Transistor’s turn off delay time td 2 ∝ sTR1 Number of character per line Dot/chara 13 Print duty specific wires CR Motor Specifications 14 Current waveform of the motorTR2 Paper Feed Motor Specifications 16 Drive circuit of paper feed motor exampleRibbon Shift Solenoid RS-SOL Specifications MP115MP onlyTiming Signal Detector Specifications 19 Circuit of timing signal 1 exampleHome Position Detector HP-sig Specifications Paper-out Detector PE-sig SpecificationsRibbon Position Detector RS-sig Specifications MP115MP only Dimension and Weight24 MP111MP External dimension unit mm 25 MP115MP External dimension unit mm Reliability Specifications Setting the Ribbon Cartridge Removing the Paper Setting the PaperSetting the Paper Installation SP2Installation space example unit mm Printer installation example unit mm Page Printer installation Power ON/OFF Note Operational NotesCarriage Motor Protection Method Against Mechanical Errors Other Notes5 V Line Power Supply Capacity24 V Line Options Paper Guide OptionDistributed by