Xantrex Technology XPL 30-2D, XPL 18-3, XPL 56-1, XPL 30-1 Meter Specifications Main Outputs

Page 4

Specification

MAIN OUTPUTS

Voltage Range:

0V to 18V minimum (XPL 18-3)

 

0V to 30V minimum (XPL 30-1, XPL 30-2, XPL 30-2D, XPL 30-2T)

 

0 to 56V minimum (XPL 56-1)

Current Range:

0A to 1A minimum (XPL 30-1)

 

0A to 1.1A minimum (XPL 56-1)

 

0A to 2A minimum (XPL 30-2, XPL 30-2D, XPL 30-2T)

 

0A to 3.3A minimum (XPL 18-3)

Voltage Setting:

By coarse and fine controls.

Current Setting:

By single logarithmic control.

Operating Mode:

Constant voltage or constant current with automatic cross-over.

Output Switch:

Electronic. Preset voltage and current displayed when off.

Output Terminals:

Universal 4mm safety binding posts on 19mm (0.75”) pitch.

Output Impedance:

Typically <5min constant voltage mode.

 

Typically >50kin constant current mode.

Output Protection:

Outputs will withstand forward voltages of up to 20V above the rated

 

output voltage. Reverse protection by diode clamp for currents up to 3A.

Load Regulation:

<0.01% of maximum output for 90% load change.

Line Regulation:

<0.01% of maximum output for 10% line change.

Ripple & Noise:

Typically <1mVrms (CV mode).

(20MHz bandwidth)

 

Transient Load Response:

<20µs to within 50mV of set level for 90% load change.

Temperature Coefficient:

Typically <100ppm/°C.

Status Indication:

Output on lamp. Constant current mode lamp.

METER SPECIFICATIONS (Main Outputs)

Meter Types:

Dual 3 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.

Meter Resolutions:

100mV, 10mA.

Meter Accuracies:

Voltage 0.3% of reading ± 1 digit.

 

Current 0.6% of reading ± 1 digit.

AUXILIARY LOGIC OUTPUT (XPL30-2T only)

Voltage:

Variable <1.5V to >5V by front panel control.

Meter Voltage Accuracy:

0.3% ± 1 digit.

Current Limit:

2A minimum.

Output Protection:

Output will withstand up to 7V forward voltage. Diode clamp reverse

 

protection for currents up to 3A.

Ripple & Noise

Typically <5mVrms, <15mVpk-pk (CV mode).

(20MHz bandwidth):

 

Load Regulation:

<3% for 90% load change.

Line Regulation:

<0.2% for 10% line voltage change.

Status Indication:

UNREG lamp.

 

 

 

3

Image 4
Contents XPL Series Linear DC Power Supply XPL XPL 30-2D XPL 30-2TPart Number Contact InformationTable of Contents IntroductionMeter Specifications Main Outputs SpecificationAuxiliary Logic Output XPL30-2T only General Emissions ImmunitySafety Installation Mains Operating VoltageFuse Mains LeadOperation Main Outputs Operation Auxiliary Output Operation GeneralCalibration Access to Calibration AdjustmentsVoltage Calibration Maintenance Sécurité AVERTISSEMENT! CET Instrument Doit Etre Relie a LA TerreTension d’utilisation secteur FusibleCâble secteur Bleu MarronFonctionnement Sorties principales Fonctionnement Sortie Auxiliaire Fonctionnement GénéralitésNettoyage Sicherheit WARNUNG! Dieses Gerät Muss Geerdet WerdenNetzbetriebsspannung SicherungNetzkabel BraunBetrieb Hauptausgänge Betrieb Hilfsausgang Betrieb AllgemeinWartung ReinigungSicurezza Attenzione Questo Strumento Deve Essere Collegato a TerraInstallazione Tensione d’esercizioFusibile Cavo d’alimentazioneFunzionamento Uscite principali Funzionamento Uscita Ausiliaria Funzionamento GeneraleManutenzione PuliziaSeguridad ADVERTENCIA! Este Instrumento Debe Conectarse a TierraInstalación Tensión de la Red EléctricaCable de Red Azul MarrónOperación Salidas principales Operación Salida Auxiliar Operación GeneralMantenimiento LimpiezaWarranty Information How do you get service?What does this warranty cover? What will Xantrex do?What does this warranty not cover? ProductReturn Material Authorization Policy Xantrex Technology Inc

XPL 30-2T, XPL 30-1, XPL 30-2D, XPL 18-3, XPL 30-2 specifications

Xantrex Technology has established itself as a leader in the power solutions market, particularly with its innovative line of XPL inverter series. This series includes models XPL 56-1, XPL 30-2, XPL 18-3, XPL 30-2D, and XPL 30-1, each designed with unique features and characteristics to meet various power needs.

The XPL 56-1 is a powerhouse inverter known for its high output capacity, making it ideal for larger applications such as recreational vehicles or off-grid systems. With a robust design and advanced thermal management technology, this model can sustain heavy loads while ensuring reliability and efficiency. Its compact structure and lightweight design facilitate easy installation and flexibility in various setups.

The XPL 30-2 and XPL 30-2D models are tailored for users looking for a balance of power and portability. Both are equipped with advanced pure sine wave output, ensuring a clean and stable power supply that protects sensitive electronics. The XPL 30-2D variant features dual output options, allowing simultaneous powering of multiple devices, enhancing versatility for users in diverse environments.

For those with smaller power requirements, the XPL 18-3 is the perfect choice, offering a smaller footprint while still delivering robust performance. This model is optimized for efficiency, enabling longer battery life in applications like camping or marine use. Its user-friendly interface allows for easy monitoring and control, making it a favorite among casual users.

The XPL 30-1 stands out for its adaptability, supporting a range of input voltages and providing adjustable output settings. This model is particularly suited for industrial applications, thanks to its rugged construction and ability to withstand harsh environments. Advanced safety features, including overload protection and short-circuit prevention, ensure that both the inverter and connected devices remain safe during operation.

In summary, the Xantrex XPL inverter series provides cutting-edge technology and versatile solutions for various power demands. Each model is engineered with specific features to cater to different user needs, ensuring reliable power during outdoor adventures, industrial operations, or off-grid living. With Xantrex’s commitment to quality and innovation, the XPL series continues to set the standard in portable and stationary power systems.