TRENDnet TFM-PCIV92A Appendix Result Codes Summary Verbose Code Numeric Code

Page 14

TFM-PCIV92A User’s Guide

TFM-PCIV92A User’s Guide

_________________________________________________________________________________________________________________________

_________________________________________________________________________________________________________________________

Appendix 4

Result Codes Summary

 

 

Verbose Code

Numeric Code

 

 

 

 

 

 

 

 

 

Verbose Code

Numeric Code

 

 

CONNECT 38000 EC*

73

 

 

OK

 

0

 

 

CONNECT 38400 EC*

28

 

 

CONNECT

 

1

 

 

CONNECT 38666 EC*

106

 

 

RING

 

2

 

 

CONNECT 40000 EC*

74

 

 

NO CARRIER

 

3

 

 

CONNECT 41333 EC*

107

 

 

ERROR

 

4

 

 

CONNECT 42000 EC*

75

 

 

CONNECT 1200 EC*

5

 

 

CONNECT 42666 EC*

108

 

 

NO DIAL TONE

 

6

 

 

CONNECT 44000 EC*

76

 

 

BUSY

 

7

 

 

CONNECT 45333 EC*

109

 

 

NO ANSWER

 

8

 

 

CONNECT 46000 EC*

77

 

 

DELAYED

 

88

 

 

CONNECT 46666 EC*

110

 

 

BLACKLISTED

 

89

 

 

CONNECT 48000 EC*

78

 

 

BLACKLIST FULL

90

 

 

CONNECT 49333 EC*

111

 

 

CONNECT 300 EC*

40

 

 

CONNECT 50000 EC*

79

 

 

CONNECT 2400 EC*

10

 

 

CONNECT 50666 EC*

112

 

 

CONNECT 4800 EC*

11

 

 

CONNECT 52000 EC*

80

 

 

CONNECT 7200 EC*

24

 

 

CONNECT 53333 EC*

113

 

 

CONNECT 9600 EC*

12

 

 

CONNECT 54000 EC*

81

 

 

CONNECT 12000 EC*

25

 

 

CONNECT 54666 EC*

114

 

 

CONNECT 14400 EC*

13

 

 

CONNECT 56000 EC*

82

 

 

CONNECT 16800 EC*

86

 

 

CONNECT 57600 EC*

18

 

 

CONNECT 19200 EC*

14

 

 

CONNECT 115200 EC*

87

 

 

CONNECT 21600 EC*

55

 

Note:

 

 

 

 

CONNECT 24000 EC*

56

 

 

* EC only appear when the extended result codes configuration option is enabled. EC is

 

 

CONNECT 26400 EC*

57

 

 

replaced by one of the following symbols, depending upon the error control method used:

 

 

CONNECT 28000 EC*

100

 

 

V.42bis

- V.42 error control and V.42bis data compression.

 

 

CONNECT 28800 EC*

58

 

 

V.42

- V.42 error control only.

 

 

CONNECT 29333 EC*

101

 

 

MNP5

- MNP class 4 error control and MNP class 5 data compression.

 

 

CONNECT 30666 EC*

102

 

 

MNP4

- MNP class 4 error control only.

 

 

CONNECT 31200 EC*

59

 

 

NoEC

- No error control protocol.

 

 

CONNECT 32000 EC*

70

 

 

 

 

 

 

 

CONNECT 33333 EC*

103

 

 

 

 

 

 

 

CONNECT 33600 EC*

60

 

 

 

 

 

 

 

CONNECT 34000 EC*

71

 

 

 

 

 

 

 

CONNECT 34666 EC*

104

 

 

 

 

 

 

 

CONNECT 36000 EC*

72

 

 

 

 

 

 

 

CONNECT 37333 EC*

105

 

 

 

 

 

 

 

 

 

- 25 -

Rev.1.00.2.1.34

 

- 26 -

Rev.1.00.2.1.34

Image 14
Contents Table of Content Contents of Package Hardware InstallationSection System Setup 2 Uninstall Modem from Windows3 Setup instructions for Windows Me 4 Uninstall Modem from Windows Me5 Setup instructions for Windows 6 Uninstall Modem from Windows 7 Setup instructions for Windows XPClick on Change/Remove Problem Modem dials but does not connect Possible solutions Testing Your ModemInstall Communication Software SectionProblem No dial tone Possible solutions Appendix Modem SpecificationsProblem Modem exhibits poor voice recording or playback Q0 Enables result code E1 Enables echoMedium speaker volume Select B212A/B103Auto rate Disables guard tone Enables data compression CD set according to carrier statusEnables fallback and fall forward Enables CTS/RTS hardware flow controlAppendix Register Summary Function Default Range Units Register Function Default Range Units Appendix Result Codes Summary Verbose Code Numeric Code FCC Class B statement Appendix 5 Government compliance noticesFCC compliance DOC compliance informationLimited Warranty

TFM-PCIV92A specifications

The TRENDnet TFM-PCIV92A is an advanced PCI Voice/Fax Modem card designed to provide reliable communication solutions for computer systems. With the increasing demand for communication technology in both home and office environments, this modem card stands out as a robust option for facilitating voice calls and faxing over traditional telephone lines.

One of the main features of the TFM-PCIV92A is its data transmission capability, operating at speeds of up to 56 Kbps for data and 33.6 Kbps for fax. This high-speed performance allows users to efficiently send and receive both voice and fax communications, making it ideal for businesses that rely heavily on faxed documents. The modem is also compatible with traditional analog phone lines, ensuring versatility and ease of installation.

The TFM-PCIV92A supports various communication protocols, which enhances its overall functionality. It is compliant with V.92 and V.90 standards, offering users improved connection reliability and faster dial-up speeds. Additionally, it incorporates error correction and data compression technologies, such as MNP5 and V.42, which ensure high-quality transmissions while minimizing the chances of data loss or corruption.

This modem is equipped with a quick-installation wizard, which simplifies the setup process, allowing users to install the card and get online within minutes. The included driver software is compatible with various operating systems, including Windows and Linux, ensuring a broad range of usability across different platforms.

Furthermore, the TFM-PCIV92A comes with built-in hardware features that enhance its performance. A robust hardware architecture ensures stable operation, while integrated surge protection safeguards against electrical spikes, prolonging the life of the modem.

In conclusion, the TRENDnet TFM-PCIV92A is an excellent choice for users seeking a reliable and efficient PCI modem. With its high-speed capabilities, support for multiple communication protocols, easy setup, and enhanced hardware features, it addresses the needs of both home users and businesses looking to maintain effective communication through voice and faxing. Whether for personal use or integral to business operations, it delivers on multiple fronts, exemplifying TRENDnet's commitment to quality and innovation in communication technologies.