SCSCF30xx-10x
Cable Specifications -- Continued
Troubleshooting
Link Budget:
Link Budget:
1310 nm (TX) / 1550 nm (RX) simplex
1550 nm (TX) / 1310 nm (RX) simplex
min: | max: |
min: | max: |
25.0 dB |
|
1300 nm multimode |
|
min: | max: |
min: | max: |
11.0 dB |
|
If the Device fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. | Is the PWR (Power) LED on the Device illuminated? |
| NO |
| • Ensure that the power adapter is the proper type of voltage and cycle |
| frequency for the outlet. |
| • Ensure the power adapter is properly installed in the Device and in the |
| grounded outlet. |
The fiber optic transmitters on this device meet Class I Laser safety requirements per
Technical Specifications
For use with Transition Networks Model
Standards | FCC Class A; EN 55022 Class A; EN 55024; ANSI | |
| ||
| tolerance; G.775 for loss of signal; Telecordia GR- | |
| 499CORE & | |
Data Rate | DS3 / T3 = 44.7 Mb/s; E3 = 34.4 Mb/s | |
Dimensions | 3.25" x 4.7" x 1.0" (83 mm x 119 mm x 25 mm) | |
Weight | 10 oz. (283 g) approximately | |
Power Consumption | 6.0 Watts |
|
Power Supply | 12 VDC, 0.8 Amp (minimum) | |
DC Outlet | Minimum output regulation: 5% | |
MTBF (stand alone) | 48,996 (MIL217F2 V5.0) | |
| 119,854 (Bellcore7 V5.0) | |
Environment | Tmra*: | 0 to 50°C (32° to 122°F ) |
| Storage Temp: |
|
| Humidity: | 5 to 95%, non condensing |
| Altitude: | 0 to 10,000 feet |
Warranty | Lifetime |
|
*Manufacturer’s rated ambient temperature.
For the most
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
| • | Contact Tech Support: |
| YES |
|
| • | Proceed to step 2. |
2. | Is the SDC (Signal Detect / Coax) LED illuminated green? | |
| NO |
|
| • | Check the coax cables for the proper connection. |
| • | Contact Tech Support: |
| YES |
|
| • | Proceed to step 3. |
3. | Is the SDF (Signal Detect / Fiber) LED illuminated green? | |
| NO |
|
| • | Check the fiber cables for proper connection. |
| • | Verify that the TX and RX cables on the local Device are connected to |
|
| the RX and TX ports, respectively, on the remote Device. |
| • | Contact Tech Support: |
| YES |
|
| • | Proceed to step 4. |
4. | Is the SDC (Signal Detect / Coax) LED flashing green? | |
| YES |
|
| • | The coax link is in |
|
| back switch to the center (normal) position. |
| • | Contact Tech Support: |
| NO |
|
| • | Proceed to step 5. |
5. | Is the SDF (Signal Detect / Fiber) LED flashing green? | |
| YES |
|
| • | The fiber link is in |
|
| back switch to the center (normal) position. |
| • | Contact Tech Support: |
| NO |
|
| • | Proceed to step 6. |
8 | techsupport@transition.com | 9 |