CALL FOR COOLING

Troubleshooting: Cooling Sequence of Operation (Continued)

CALL FOR COOLING

1

1ST STAGE COOLING REQUEST RECEIVED 1

WAIT FOR COMPRESSOR TIMED

OFF DELAY TO EXPIRE

ENERGIZE 1ST STAGE COOLING CONTACTOR (COMPRESSOR & FAN)

INDOOR BLOWER 2

SECOND ON DELAY

ENERGIZE INDOOR BLOWER

2

(LOW COOLING MODE)

MAINTAIN INDOOR

BLOWER

(LOW COOLING MODE)

Manual backgroundYES

YES

 

1

 

 

1ST STAGE

2ND STAGE

 

 

 

 

 

 

NO

 

COOLING REQUEST

COOLING

 

 

 

 

 

 

 

 

 

 

STILL ACTIVE?

REQUEST?

 

 

 

 

YES

YES

ENERGIZE 2ND STAGE

 

ENERGIZE INDOOR BLOWER

 

COOLING CONTACTOR

 

(HIGH COOLING MODE)

2

(COMPRESSOR & FAN)

 

 

 

 

 

 

 

 

NO

2ND STAGE

 

MAINTAIN INDOOR BLOWER

COOLING REQUEST

YES

(HIGH COOLING MODE)

STILL ACTIVE?

 

 

 

NO

 

 

DE−ENERGIZE 2ND

 

 

STAGE COOLING

 

 

CONTACTOR

 

 

(COMPRESSOR & FAN)

 

 

1ST STAGE

 

ENERGIZE AND MAINTAIN

COOLING REQUEST

YES

INDOOR BLOWER AT

STILL ACTIVE?

 

(LOW COOLING MODE)

 

 

NO

 

 

DE−ENERGIZE 1ST

STAGE COOLING

CONTACTOR

(COMPRESSOR & FAN)

DE−ENERGIZE INDOOR

BLOWER 2

1CONTROL WILL NOT RESPOND TO A 2ND STAGE COOLING REQUEST UNLESS A 1ST STAGE COOLING REQUEST IS ACTIVE.

2INDOOR BLOWER LOW COOLING MODE AND HIGH COOLING MODE HAVE SPECIFIC ON, OFF AND SPEED RAMPING PROFILES. THE SPECIFIC PROFILE IS SELECTED USING THE

DIP SWITCHES ON THE CONROL.