Generator Use − Voltage Requirements | S | The furnace integrated control requires both correct | |
The following requirements must be kept in mind when |
| polarity and proper ground. Both polarity and proper | |
| grounding should be checked before attempting to op- | ||
specifying a generator for use with this equipment: |
| ||
| erate the furnace on either permanent or temporary | ||
S The furnace requires 120 volts (Range: 102 volts to |
| ||
| power | ||
132 volts) |
| ||
S | Generator should have a wave form distortion of less | ||
S The furnace operates at 60 Hz + 5% (Range: 57 Hz to | |||
| than 5% THD (total harmonic distortion) | ||
63 Hz) |
| ||
|
|
icomfort Touch® Thermostat with SL280DFV
and Non−Communicating Outdoor Unit
icomfort Touch® Thermostat
icomfortt−Enabled SL280DFV Indoor Furnace Non−Communicating Outdoor Air Conditioner
icomfort Touch® Thermostat with SL280DFV
and icomfortt−ENABLED Outdoor Unit
icomfort Touch® Thermostat
icomfortt−Enabled SL280DFV Indoor Furnace
icomfortt−Enabled Outdoor Air Conditioner or Heat Pump
icomfortt−
ENABLED
SL280DFV
FURNACE
OPTIONAL
DISCHARGE
AIR SENSOR
icomfort Touch®
THERMOSTAT
OPTIONAL OUTDOOR AIR SENSOR
icomfortt−
ENABLED SL280DFV
FURNACE
OPTIONAL
DISCHARGE
AIR SENSOR
OPTIONAL OUTDOOR AIR SENSOR
icomfort Touch®
THERMOSTAT
icomfortt− ENABLED
OUTDOOR AIR CONDITIONING
OR HEAT PUMP UNIT
NON−COMMUNICATING
OUTDOOR AIR
CONDITIONING UNIT −
1 OR 2 STAGE
CLIP ON−BOARD LINK
W915 (Y1 TO Y2) FOR
TWO−STAGE OPERATION
NOTE − On communicating systems, extra wires must terminate on the "C" RSBus terminal. Use an additional wire and come off "C" terminal and wire nut all the extra wires together. Termination on the outdoor control must match the indoor control.
icomfortt Integrated Control
Outdoor Unit
icomfort Touch®
FIGURE 21
Page 23