Planned Service

Planned Service

The following items should be checked during an annual inspection. Power to the unit must be shut off for the service techni- cian’s safety.

Fresh air grilles and louvers (on the unit and in the room where the furnace is installed) − Must be open and unob- structed to provide combustion air.

Burners − Must be inspected for rust, dirt, or signs of water.

Vent pipe − Must be inspected for signs of water, damaged or sagging pipe, or disconnected joints.

Unit appearance − Must be inspected for rust, dirt, signs of water, burnt or damaged wires, or components.

Blower access door − Must be properly in place and pro- vide a seal between the return air and the room where the furnace is installed.

Return air duct − Must be properly attached and provide an air seal to the unit.

Operating performance − Unit must be observed during operation to monitor proper performance of the unit and the vent system.

Combustion gases − Flue products must be analyzed and compared to the unit specifications.

Problems detected during the inspection may make it nec- essary to temporarily shut down the furnace until the items can be repaired or replaced.

Instruct the homeowners to pay attention to their furnace. Situations can arise between annual furnace in- spections that may result in unsafe operation. For instance, items innocently stored next to the furnace may obstruct the combustion air supply. This could cause incomplete combustion and the production of carbon monoxide gas.

Repair Parts List

The following repair parts are available through independent Lennox dealers. When ordering parts, include the complete furnace model number listed on the CSA International nameplate −− Example: SL280DF070V36A.

All service must be performed by a licensed professional installer (or equivalent), service agency, or gas supplier.

Cabinet Parts

Upper access panel

Blower panel

Top cap

Control Panel Parts

Transformer

Two−stage, variable speed integrated control Door interlock switch

Circuit breaker Blower Parts

Blower wheel Blower housing Motor

Motor electronics Power choke (1 hp only) Motor mounting frame Blower housing cutoff plate

Heating Parts

Flame Sensor

Heat exchanger assembly Gas manifold

Two−speed combustion air inducer Two−stage gas valve

Main burner cluster Main burner orifices Pressure switch Ignitor

Primary limit control Flame rollout switch

Secondary limit

Page 47

Page 47
Image 47
Lennox International Inc DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE, SL280DFV Planned Service, Repair Parts List