Lennox International Inc SL280DFV Integrated Control Diagnostic Codes continued

Models: DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE SL280DFV

1 60
Download 60 pages 14.92 Kb
Page 54
Image 54
LSOM − Compressor open start circuit.

Integrated Control Diagnostic Codes (continued)

E 406

LSOM − Compressor open start circuit.

Required amount of current is not passing through

 

 

Start current transformer. Clears the error after cur-

 

 

rent is sensed in START sensor, or after power re-

 

 

set.

 

 

 

E 407

LSOM − Compressor open run circuit.

Required amount of current is not passing through

 

 

Run current transformer. Clears the error after cur-

 

 

rent is sensed in RUN sensor, or 1 normal compres-

 

 

sor run cycle, or after power reset.

 

 

 

E 408

LSOM − Compressor contactor is welded.

Compressor runs continuously. Clears the error

 

 

after 1 normal compressor run cycle or after power

 

 

reset.

 

 

 

E 409

LSOM − Compressor low voltage.

Secondary voltage is below 18VAC. After 10 min-

 

 

utes, operation is discontinued. Clears the code

 

 

after voltage is higher than 20 VAC for 2 seconds or

 

 

after power reset.

 

 

 

Page 54

Page 54
Image 54
Lennox International Inc SL280DFV Integrated Control Diagnostic Codes continued, LSOM − Compressor open start circuit