Transition Networks SBFTF10XX-10X specifications Installation, Set the Configuration Switches

Page 2
Link Pass-Through Disable

SBFTF10xx-10x

Part Number

Port One - Copper

Port Two - Simplex Fiber-Optic

 

 

 

SBFTF1029-100 **

RJ-45

SC, 1310 nm (TX)/1550 nm (RX)

 

100 m (328 ft)*

single mode, 20 km (12.4 miles)*

SBFTF1029-101 **

RJ-45

SC, 1550 nm (TX)/1310 nm (RX)

 

100 m (328 ft)*

single mode, 20 km (12.4 miles)*

 

 

 

SBFTF1029-102 **

RJ-45

SC, 1310 nm (TX)/1550 nm (RX)

Installation -- Continued

Set the Configuration Switches - Continued

3. Twisted-Pair Mode

 

100 m (328 ft)*

single mode, 40 km (24.8 miles)*

SBFTF1029-103 **

RJ-45

SC, 1550 nm (TX)/1310 nm (RX)

 

100 m (328 ft)*

single mode, 40 km (24.8 miles)*

SBFTF1035-100

RJ-45*

SC, 1550 nm single mode, 120 km

Long Wave length

100 m (328 ft)

(74.6miles)*

SBFTF1039-100

RJ-45*

LC, 1300 nm multimode, 2 km

 

100 m (328 ft)*

(1.2 miles)*

*Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network. (TX) = transmit (RX) = receive

**CBFTF1029-100/101 pair or -102/103 pair should be installed in the same network where one as local and the other is the remote converter.

UP (Full-Duplex):

The twisted-pair cable distances are constrained by the cable requirements (see pages 1 and 2).

DOWN (Half-Duplex):

At the 100Base-TX rate, the twisted-pair cable distances are constrained by the 512-Bit Rule (see page 9).

At the 10Base-T rate, the twisted-pair cable distances are constrained by the 5-Segment Rule (see page 10).

3

UP

Twisted-pair Full-Duplex

DOWN

Twisted-pair Half-Duplex

Installation

Set the Configuration Switches

The configuration switches are located on the side of the media converter. Use a small, flat-blade screwdriver or a similar device to set each switch.

NOTE:

Switches 1, 2, 3, and 5 apply to the copper port.

Switch 4 applies to the fiber port.

Switch 6 applies to the media converter.

4. Fiber Mode

UP (Full-Duplex)- The fiber cable distances are constrained by the cable requirements (see pages 1 and 2).

DOWN (Half-Duplex)- The fiber cable distances are constrained by the 512-Bit Rule (see page 10).

5. AutoCross

4

UP

Fiber Full-Duplex

DOWN

Fiber Half-Duplex

5

1. Twisted-Pair Auto-Negotiation

UP (Enabled) - The media converter “advertises” ALL rate and mode capabilities to the network:

100Mb/s full-duplex,

100Mb/s half-duplex,

10Mb/s full-duplex, and

10Mb/s half-duplex.

1

UP

Twisted-pair Auto-Negotiation ON

DOWN

Twisted-pair Auto-Negotiation OFF

UP (Enable) - The media converter connects automatically to either straight-through or crossover twisted-pair copper cable.

DOWN (Disable) - Either straight-through or crossover twisted-pair copper cable must be installed, according to the site requirements.

UP

AutoCross Enable

DOWN

AutoCross Disable

DOWN (Disabled) - The bridging media converter does not “advertise” the rate and mode capabilities to the network. Switch #2 and switch #3 are then used to set the twisted-pair rate and mode.

2. Twisted-Pair Rate

2

UP - Sets the twisted-pair rate to 100Base-TX.

UP

 

DOWN - Sets the twisted-pair rate to 10Base-T.

Twisted-pair 100Base-TX

 

 

DOWN

 

Twisted-pair 10Base-T

6. Link Pass-Through

6

UP (Enable) - When Link Pass-Through is enabled, a

UP

fault on one side of the media converter stops the

Link Pass-Through Enable

signal and data transmission on the other side.

DOWN (Disable) - When Link Pass-Through is

DOWN

disabled, a fault on one side of the media converter does not stop the signal and data transmission on the other side.

2

24-Hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

3

Image 2
Contents User’s Guide Stand Alone Media ConverterInstallation Set the Configuration SwitchesConnect the Fiber Cable Power the Media ConverterConnect the Twisted-Pair Copper Cable Operation Using the Status LEDsProduct Features Bit Rule 100Base-TX or 100Base-FX Optional Accessories sold separatelyHalf-Duplex Network Segment Rule 10Base-T Half-Duplex Network Cable SpecificationsFiber Cable 100Base-TX Fiber ExampleIs the power LED illuminated? Technical SpecificationsTroubleshooting Copper CableIs the Link in the proper position? Compliance InformationIs the Lact LED illuminated on the fiber port? European RegulationsContact Us