4
NOTE: As of this release, the Server Switch Module does not support the
Server Switch Module Status LEDs
Module Status LEDs provide an
Table
Table
State | Indication |
both LEDs off | No system power or LED malfunction. |
|
|
yellow solid, green off | Module error detected: operator intervention required. |
|
|
green solid, yellow off | Module running with no errors detected. |
|
|
Port Status LEDs
The port LEDs on the Server Switch Module indicate connection and transmission status (Table
Link LEDs indicate connection status (Table
Table
Status | Indication |
off | No logical connection through the interface. |
|
|
solid green | Indicates that a physical link is established, with drivers installed and running. |
|
|
Table | |
|
|
Status | Indication |
off | No traffic runs over the interface. |
|
|
blinking green | Traffic runs successfully over the interface. |
External InfiniBand Ports
To support three 4x ports, the 12x InfiniBand connector on the Server Switch Module becomes three 4x connectors through an “octopus cable.” This cable begins as one 12x connector (which connects to your Server Switch Module), then branches into three 4x connectors to which you can attach additional InfiniBand hardware. The physical connectors are numbered 1 through 4 from top to bottom (where the independent 4x connector on the Server Switch Module is at the top).
In all user interfaces, however, the port numbers begin at 15. Ports 1 through 14 function internally, then ports 15 - 18 connect the Server Switch Module to external devices. Connector 1 maps to port 15, connector 2 to port 16, and so on.