Honeywell 6039 owner manual Engine ON/OFF Switch, Fuel Shut-off Valve - Choke Position, Operation

Models: 6039

1 24
Download 24 pages 7.83 Kb
Page 12
Image 12
Figure 12 - Engine ON/OFF Switch

Operation

Figure 12 - Engine ON/OFF Switch

Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

1.Unplug all electrical loads from the unit's receptacles before starting the engine.

2.Make sure the unit is in a level position (not to exceed 15° in any direction).

3.OPEN the Fuel Shut-off Valve (Figure 10).

4.Turn engine RUN/STOP switch to ON position (Figure 12).

5.Slide engine choke to the LEFT to FULL CHOKE position (Figure 11).

6.To start engine, firmly grasp the recoil handle and pull slowly until increased resistance is felt. Pull rapidly up and away.

7.When engine starts, move choke knob to 1/2-CHOKE position until engine runs smoothly and then fully into RUN position. If engine falters, move choke back out to 1/2-CHOKE position until engine runs smoothly and then to RUN position.

NOTE:

If engine fires, but does not continue to run, move choke lever to FULL CHOKE and repeat starting instructions.

Figure 10 - Fuel Shut-off Valve

Figure 11 - Choke Position

CHOKE LEVER

LEFT = CHOKE (START)

RIGHT = RUN

IMPORTANT: Do not overload the generator. Also, do not overload individual panel receptacles. These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” carefully.

Never start or stop engine with electrical devices plugged into the receptacles AND devices turned on.

1.Unplug all electrical loads from the unit's receptacles before starting the engine.

2.Make sure the unit is in a level position (not to exceed 15° in any direction).

3.Open the fuel shut-off valve (Figures 10).

4.Move engine CHOKE knob outward to FULL CHOKE position (Figure 11).

5.To start engine, press and hold the Start/Run/Stop switch in the “Start” position. The engine will crank and attempt to start. When the engine starts, release the switch to the run position.

6.When the engine starts, move choke knob to “1/2 Choke” position until the engine runs smoothly and then fully in to the “Run” position. If engine falters, move choke knob back out to “1/2 Choke” position until the engine runs smoothly and then to “Run” position.

This generator is also equipped with a manual recoil starter which may be used if the battery is discharged.

10

Page 12
Image 12
Honeywell 6039 owner manual Engine ON/OFF Switch, Fuel Shut-off Valve - Choke Position, Operation