Honeywell 6039 Generator Controls - Generator Controls, 120 Volt AC, 20 Amp, Duplex Receptacle

Models: 6039

1 24
Download 24 pages 7.83 Kb
Page 8
Image 8
Figure 3 - Generator Controls

17.Battery Charger Input – This receptacle allows the capability to recharge the 12 volt DC storage battery provided with the 12 Volt Adaptor Plug Charger which is included in the Accessory Box. Located behind the battery charger input is a 1.50 Amp in-line fuse which is inside the control panel to protect the battery (electric start models only).

18.Battery – Powers the electric starter (electric start models only).

Figure 3 - Generator Controls

Figure 4 - Generator Controls

This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 5). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).

Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible overheating of wires.

Figure 5 - 120 Volt AC, 20 Amp, Duplex Receptacle

This is a 120 Volt outlet protected against overload by a 20 Amp push-to-reset circuit breaker (Figure 6). Use each socket to power 120 Volt AC, single phase, 60 Hz electrical loads requiring up to a combined 2400 watts (2.4 kW) or 20 Amps of current. Use only high quality, well-insulated, 3-wire grounded cord sets rated for 125 Volts at 20 Amps (or greater).

Keep extension cords as short as possible to prevent voltage drop and possible overheating of wires.

Figure 6 - 120 Volt AC, 20 Amp, GFCI Duplex Receptacle

6

Page 8
Image 8
Honeywell 6039 owner manual Generator Controls - Generator Controls, 120 Volt AC, 20 Amp, Duplex Receptacle