Parameter | Description | Values |
|
|
|
notify | The user | username@hostname or user@localhost |
| messages. This parameter uses the rmail utility |
|
| available in the UNIX System V mail facility to |
|
| deliver the completion messages. |
|
| Note: Sterling Connect:Direct does not validate |
|
| the |
|
| notify parameter. Invalid |
|
| failed |
|
| to the local mail facilities configuration. |
|
|
|
|
pacct | A string containing information about the | “pnode accounting data” up to 256 characters |
| PNODE. Enclose the string in double quotation |
|
| marks. |
|
|
|
|
pnodeid | Security user IDs and passwords at the | id [, pswd] |
| PNODE. The pnodeid subparameters can | |
| contain | |
|
| |
|
| PNODE. If you specify pnodeid, you must also |
|
| specify id. Identify the ID first and the pswd last. |
|
|
|
prty | The priority of the Process in the Transmission | |
| Control Queue (TCQ). A Process with a higher | default is 10. |
| priority is selected for execution before a |
|
| Process with a lower priority. The prty value |
|
| does not affect the priority during |
|
| transmission. |
|
|
|
|
retain | Determines if Sterling Connect:Direct retains a | yes no initial |
| copy of the Process in the TCQ. Sterling | |
| Connect:Direct assigns a Process number to the | |
| Process when it is placed in the retain queue. | in the Hold queue in HR status after execution. |
| When the Process is run, the Process number | |
| assigned to the retain Process is incremented | |
| from the TCQ after execution. This is the default. | |
| by one. For example, if the Process is assigned | |
|
| |
| the Process number of 1445 in the retain | |
| queue, the Process number is 1446 when the | |
| Process in the Hold queue in HR status for | |
| Process is executed. | |
| automatic execution every time the Process | |
|
| |
| If you specify a start time and set retain=yes, | Manager initializes. |
|
| |
| the Process remains in the Timer queue in HR |
|
| status and is submitted at the appropriate |
|
| interval. For example, when |
|
| startt=(Monday,2:00), the Process runs each |
|
| Monday at 2:00 AM. When startt=(,1:00), the |
|
| Process runs daily at 1:00 AM. Sterling |
|
| Connect:Direct does not provide a way to run |
|
| a Process hourly. To do this, you must use the |
|
| UNIX cron utility. |
|
| If no start time is identified, you must issue a |
|
| change process command to release the |
|
| Process for execution. Do not code the startt |
|
| parameter when you specify retain=initial. |
|
|
|
|
sacct | Specifies accounting data for the SNODE. | “snode accounting data” up to 256 characters. |
| Setting this value in the submit statement | Enclose the string in double quotation marks. |
| overrides any accounting data specified in |
|
| Process. |
|
|
|
|
8Sterling Connect:Direct for UNIX: User Guide