Installation Instructions
7.0 Installation Time
FFBM | Machine Hrs. | System Hrs. | Nbr of CEs |
|
|
|
|
10K8798 | 0.2 | 0.0 | 1 |
|
|
|
|
Note: To reduce the MES installation time it is recommended that you load the Network Node Processor Code on the Service Processor and install the system unit at the same time.
No impact on 3745 customer operations.
8.0 Tools/Material Required
None.
Installation (Steps 9-12)
9.0 Safety
Review the Safety Notices and the Safety Inspection Procedures located at the beginning of the IBM 3745 Communication Controller All Models, IBM 3746 Expansion Unit Model 900, IBM 3746 Nways Multiprotocol Controller Model 950 Safety Information,
10.0Details of Installation
10.1Installing and Connecting the NNP
Note: For any unexpected message or error concerning the
1.Using the Network Node Processor Installation and Maintenance (Based on 6578),
2.Ask the customer for a maintenance window on
3746 | PN 42L2445 |
FFBM | 6 of 10 |
|
|
6
EC F52322 | EC F12701A | EC F70078 | EC F70110 | EC H10024 |
09 Oct 1998 | 14 DEC 1998 | 22 APR 1999 | 20 JAN 2000 | 08 MAR 2001 |
|
|
|
|
|