d)If an error is detected in initial self-diagnosis the LED blinks. In this case, it is recommended to issue the REQUEST SENSE command from the initiator (host system) to obtain information (sense data) for error analysis.

IMPORTANT

The LED lights during the IDD is executing a command. However, in same commands, the lighting time is only an instant. Therefore, it seems that the LED blinks or the LED remains off.

5.6.2Checking SCSI connection

When the initial operation is checked normally after power is turned on, check that the IDD is connected to the SCSI bus from the host system. Although checking the connection depends on the structure of the host system, this section describes the general procedures.

(1)Checking procedure

Issuing the commands and determining the end status depends on the start mode of the spindle motor and UNIT ATTENTION report mode (specified with setting terminal). Figure 5.4 shows the recommended checking procedure for the mode that the motor starts when power is turned on. Figure 5.5 shows for the mode that the motor starts by the START/STOP command. In these recommended checking procedures, following items are checked.

Note:

Following steps a) to d) correspond to a) to d) in Figures 5.4 and 5.5.

a)Issue the TEST UNIT READY command and check that the IDD is connected correctly to the SCSI bus and the initial operation after power is turned on ended normally. The command issue period of the TEST UNIT READY command shall be more than 20 ms.

b)To control starting of the spindle motor from the host system, issue the START/STOP UNIT command to start the spindle motor.

c)Check the SCSI bus operations with the WRITE BUFFER and READ BUFFER commands. Use data whose data bus bits change to 0 or 1 at least once. (Example: Data with an increment pattern of X'00' to X'FF')

d)Start the IDD self-diagnostic test with the SEND DIAGNOSTIC command and check the basic operations of the controller and disk drive.

5-14

C141-E205

Image 86
Contents C141-E205-01EN For Safe Operation Revision Record Related Standards Preface General DescriptionConventions for Alert Messages Important Alert Items Important Alert MessagesTask Alert message Mounting Installation Manual Organization Product Maintenance This page is intentionally left blank Contents Diagnostics and Maintenance Appendix B Connector Signal Allocation IN-1Figures Page Tables Standard Features Hardware Structure System Configuration General DescriptionStandard Features C141-E205 Page Page NC model drives outer view Page System configuration Scsi ID LUNThis page is intentionally left blank Hardware Specifications Model name and order number SpecificationsHardware Specifications Scsi Function Specifications Model names and order numbers32/34 Meeprml Function specificationsMAU3147NC/NP MAU3073NC/NP MAU3036NC/NP ScsiPage Iops Environmental specificationsEnvironmental/power requirements MTBF= Error rateReliability Temperature is 60C or less Shows the Scsi functions provided with the IDD This page is intentionally left blank Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Format Data SpaceSA0 Alternate spare area Spare area in cell Track format Track skew/head skew Sector formatPage Format capacity MAU3147NC/NPPage Defect Management Defect list Alternate block allocationPage Alternate block allocation by Format Unit command Alternate block allocation by Reassign Blocks command Write Write Extend Format UnitC141-E205 This page is intentionally left blank Installation Requirements Mounting Requirements External dimensionsNC external dimensions NP external dimensions Mounting IDD orientationsMounting frame structure MPU Surface temperature check pointHDC Surface temperature measurement points Spin-up current waveform +12 VDC 10 Power on/off sequence Delay time of spindle motor starting 13 NC connectors location 14 SCA2 type 16-bit Scsi connector 2 68-pin connector type 16-bit Scsi model NP model 15 NP connectors and terminals location16 68-pin type 16-bit Scsi interface connector GND EsidLED WTP20 16-bit Scsi ID external input IDD 21 Output signal for external LED 22 Scsi cables connection Cable connector requirements Recommended components for connectionLED ID0 ID1 ID2 ID3 External operator panel on NP model drives onlyGND LED C141-E205 Installation Page Connections Scsi bus connections 1 CN2 CN2 setting terminal on NP models only Scsi ID setting Scsi ID #15Scsi Motor start mode setting Each mode settingSetting Scsi terminator power supply NP model Setting the bus width of the Scsi interface NP model Write protect setting NP modelSetting of the Scsi interface operation mode NP model GND/WTPSCSI-3 Mode settingsDefault mode settings by Change Definition command Mounting Drives Check before mounting Setting check list NP model onlyMounting procedures Connecting Cables Remark Checking Scsi connection Checking the Scsi connection a Checking the Scsi connection B Formatting Page Setting parameters Awre ArreArre Awre PER Xxxx DiscXffff Read/write This page is intentionally left blank Self-diagnostic functions Diagnostics and MaintenanceDiagnostics Self-diagnostics Page Operation of self-diagnostics Test programs Maintenance Information Precautions Maintenance requirements C141-E205 Maintenance levels Revision numbers Revision labelIndicating revision numbers Tools and test equipment TestsTest flowchart Operation test Diagnostic testOperation Check Initial seek operation check Troubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense data Error AnalysisError Analysis Information Collection Sense Data Analysis MSB ILILSB SksvError information indicated with sense data Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-40-xx, and 4-C4-xxAppendix a Setting Terminals Setting Terminals on NP model onlyScsi ID Appendix B Connector Signal Allocation Diffsns GND ATN BSY ACK RST MSG SEL REQ DBP1Pcrca GND Diffsns Termpwr This page is intentionally left blank CN1 IndexBcrc PAD Mode SELECT/MODE SelectECC Programmable multi-segment data buffer This page is intentionally left blank Comment Form This page is intentionally left blankw
Related manuals
Manual 2 pages 14.65 Kb

MAU3036NC/NP, MAU3147NC/NP, MAU3073NC/NP specifications

The Fujitsu MAU3036NC/NP, MAU3147NC/NP, and MAU3073NC/NP are advanced models designed to offer high performance and reliability in various computing environments. These models are particularly notable for their optimized efficiency and robust feature set, making them suitable for a range of applications from enterprise servers to high-performance computing.

One of the standout features of the MAU series is its reliance on cutting-edge technology that maximizes data handling capabilities. The MAU3036NC/NP boasts a formidable capacity for high-speed data processing, making it ideal for tasks requiring quick data retrieval and storage. With an optimized caching mechanism, this model enhances data throughput and reduces latency, contributing to an overall faster response time in demanding applications.

The MAU3147NC/NP introduces further advancements with its enhanced thermal management system. This ensures that the unit operates at optimal temperatures, reducing the risk of overheating and prolonging the lifespan of the hardware. Additionally, this model implements advanced error-correcting code (ECC) memory, which significantly improves reliability by detecting and correcting internal data corruption, a crucial feature in mission-critical environments.

Meanwhile, the MAU3073NC/NP excels in terms of scalability. Its architecture allows for easy upgrades and expansions, accommodating growing data needs without significant downtime. This flexibility is essential for businesses looking to future-proof their operations and adapt to changing demands seamlessly.

All three models incorporate Fujitsu's innovative energy-efficient technologies, which not only reduce power consumption but also align with global sustainability goals. The intelligent power management systems make these units not only cost-effective but also environmentally friendly, demonstrating Fujitsu's commitment to responsible manufacturing.

Furthermore, robust connectivity options, including multiple interface support, make these models easily integrable into existing IT infrastructures. They are compatible with a variety of operating systems and software, ensuring that users can leverage their full potential regardless of their specific setup.

In summary, the Fujitsu MAU3036NC/NP, MAU3147NC/NP, and MAU3073NC/NP series exemplify the blend of performance, reliability, and efficiency. With features tailored to meet the evolving needs of modern businesses, these models stand out in the competitive landscape of computing solutions, ensuring that users can address both current and future challenges in data management and processing.