Fujitsu MAY2036RC, MAY2073RC manual Troubleshooting Procedures

Page 75

6.4 Troubleshooting Procedures

6.4Troubleshooting Procedures

6.4.1Outline of troubleshooting procedures

This section explains the troubleshooting procedures for disk drive errors.

Depending on the maintenance level, analyze the error to detect a possibly faulty part (disk drive, or disk drive part).

Full-scale troubleshooting is usually required if the error cause is not known. If the error cause is clear (e.g., abnormal noise in disk enclosure or burning of the PCA), troubleshooting is straightforward.

6.4.2Troubleshooting with disk drive replacement in the field

At this level of maintenance, we recommend replacing the disk drive as a unit. If replacing the disk drive rectifies the fault, return the removed disk drive to the factory, for test and repair. If the newly installed disk drive does not rectify the fault another part of the system is faulty.

Table 6.2 summarizes system-level field troubleshooting. Troubleshooting must be done in the field, to find faulty part (disk drive or system).

C141-E230

6-11

Image 75
Contents C141-E230-01EN For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsInterface Maintenance ManualSpecifications Manual Organization ProductThis page is intentionally left blank Contents Contents InstallationGL-1 Figures Tables This page is intentionally left blank Standard Features Standard Features Hardware Structure System ConfigurationGeneral Description Standard Features General Description Hardware Structure System Configuration Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers 60/63 Meeprml SpecificationsFunction specifications MAY2073RC MAY2036RCHardware Specifications Environmental/Power requirements Environmental specificationsError rate ReliabilityMtbf = Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting Requirements Mounting frame structure example Surface temperature check point and maximum temperature HDCMPU Service clearance area Current waveform +12V DC Power Supply RequirementsConnector location Connection Requirements Interface connectorInterface connector SAS plug signal allocationCN1 11 Recommended external circuit for Ready LED output Ready LED output signalThis page is intentionally left blank Installation Installation Setting Setting Port AddressMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Awre ArreArre Awre PER Disc XffffXxxx Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions Maintenance InformationMaintenance requirements Revision numbers Maintenance levelsIndicating revision numbers Tools and test equipment Tests Test flowchartDiagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting with disk drive replacement in the field Troubleshooting ProceduresSystem-level field troubleshooting Disk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting with parts replacement in the factoryError Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisSksv Error AnalysisILI LSBDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx, Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary Target Targ GlossaryAcronyms and Abbreviations OEM Acronyms and AbbreviationsECC BcrcPAD Mode SELECT/MODE SelectIndex Mtbf MttrC141-E230 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank
Related manuals