Fujitsu MAY2073RC, MAY2036RC manual Data Format

Page 30

Data Format

Physics Cylinder

-Z

System space

-4

Cylinder0

Head0

1

m-1

Cylinder0

Head1

m-1

 

 

 

Cylinder0

 

 

 

 

 

 

1

 

 

Head

 

 

 

 

 

 

 

Zone0

(a-1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m-1

 

 

 

 

 

 

 

 

Spare sectors for each cell

User space

Track

 

 

 

m-1

 

 

 

 

 

 

 

 

 

Spare sectors for each cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Change

 

1

 

 

 

 

 

for cell

 

 

 

 

 

 

 

(b-1)

 

 

Alternate Cell

(b)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m-1

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone1

Zone (X-1)

(C)

Spare Cylinder

Last Cylinder

Note: Spare sectors on the last track in each cylinder are not necessarily placed at the end of the track (b-1)

because of a track skew or a cylinder skew. (Details are explained in Subsection 3.1.3.)

Figure 3.1 Cylinder configuration

Apart from the above logical configuration, the HDDs intend to increase the storage capacity by dividing all cylinders into several zones and changing a recording density of each zone.

3-2

C141-E230

Image 30
Contents C141-E230-01EN For Safe Operation Revision Record Related Standards Preface Overview of ManualPreface Conventions for Alert MessagesImportant Alert Items Important Alert MessagesImportant Alert Items Data lossManual Organization Product Maintenance ManualSpecifications InterfaceThis page is intentionally left blank Contents Installation ContentsGL-1 Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration Standard FeaturesGeneral Description Standard Features General Description Hardware Structure System Configuration Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers MAY2073RC MAY2036RC SpecificationsFunction specifications 60/63 MeeprmlHardware Specifications Environmental specifications Environmental/Power requirementsError rate ReliabilityMtbf = Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocationAlternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements DimensionsInstallation Requirements Mounting orientationsMounting Requirements Mounting frame structure example Surface temperature check point and maximum temperature HDCMPU Service clearance area Power Supply Requirements Current waveform +12V DCConnector location Interface connector Connection RequirementsInterface connector SAS plug signal allocationCN1 Ready LED output signal 11 Recommended external circuit for Ready LED outputThis page is intentionally left blank Installation Installation Setting Setting Port AddressMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Awre ArreArre Awre PER Disc XffffXxxx Dismounting Drives Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information PrecautionsMaintenance requirements Maintenance levels Revision numbersIndicating revision numbers Tools and test equipment Test flowchart TestsDiagnostic test Operation Check Initial seek operation checkOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataLSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx,Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations OEMBcrc ECCMtbf Mttr Mode SELECT/MODE SelectIndex PADC141-E230 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank
Related manuals
Manual 1 pages 7.73 Kb