Error Analysis

7.2.2Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx)

Sense data (3-0C-03), (4-32-01), (4-40-xx), (4-C4-xx), and (4-44-xx) indicate one of the following:

A target sector could not be detected using the sector counter.

A seek process overran the specified time.

A write to a disk terminated abnormally.

An error occurred in power-on self-diagnosis.

A drive error occurred.

The symptoms above are generally caused by an error in a PCA or DE.

7.2.3Sense data (1-1x-xx), (3-1x-xx) and (E-1D-00): Disk read error

If sense data (1-1x-xx), (3-1x-xx) or (E-1D-00) occurs frequently in a specific block of a disk, there is disk damage that was not recorded in the media defect list. In this case, assign an alternate block to the error-detected block using a REASSIGN BLOCKS command. For an explanation of the REASSIGN BLOCKS command, refer to Subsection 4.3.2 “REASSIGN BLOCKS (07)” of the Interface Specifications.

If this error occurs in different blocks, a PCA or DE is faulty.

7.2.4Sense data (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00): interface error

Sense data (5-2x-xx), (B-44-xx), (B-47-xx), (B-4B-xx) and (B-4E-00) indicate one of the following symptoms:

An invalid or unsupported command was issued, or invalid or unsupported parameters were specified.

An interface error occurred.

A hardware error occurred inside HDDs.

If this error occurs, the PCA or the interface is faulty.

7-4

C141-E230

Image 82
Contents C141-E230-01EN For Safe Operation Revision Record Related Standards Preface Overview of ManualPreface Conventions for Alert MessagesImportant Alert Items Important Alert MessagesImportant Alert Items Data lossManual Organization Product Maintenance ManualSpecifications InterfaceThis page is intentionally left blank Contents Installation ContentsGL-1 Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration Standard FeaturesGeneral Description Standard Features General Description Hardware Structure System Configuration Hardware Specifications Model name and order number Hardware SpecificationsModel names and order numbers MAY2073RC MAY2036RC SpecificationsFunction specifications 60/63 MeeprmlHardware Specifications Environmental specifications Environmental/Power requirementsReliability Error rateMtbf = Specifications Data Space Logical Data Block Addressing Defect Management Cylinder configurationData Space Data Format Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocationAlternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements DimensionsInstallation Requirements Mounting orientationsMounting Requirements Mounting frame structure example HDC Surface temperature check point and maximum temperatureMPU Service clearance area Power Supply Requirements Current waveform +12V DCConnector location Interface connector Connection RequirementsInterface connector SAS plug signal allocationCN1 Ready LED output signal 11 Recommended external circuit for Ready LED outputThis page is intentionally left blank Installation Installation Setting Port Address SettingMounting Drives Mounting procedures Installation Formatting Installation Setting parameters Arre AwreArre Awre PER Xffff DiscXxxx Dismounting Drives Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information PrecautionsMaintenance requirements Maintenance levels Revision numbersIndicating revision numbers Tools and test equipment Test flowchart TestsOperation Check Initial seek operation check Diagnostic testOperation test Troubleshooting Procedures Troubleshooting with disk drive replacement in the fieldSystem-level field troubleshooting Troubleshooting at the repair site Disk drive troubleshootingTroubleshooting with parts replacement in the factory Finding possibly faulty partsError Analysis Information Collection Sense Data Analysis Error Analysis Information Collection Sense dataLSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx,Glossary Glossary Target TargAcronyms and Abbreviations Acronyms and Abbreviations OEMBcrc ECCMtbf Mttr Mode SELECT/MODE SelectIndex PADC141-E230 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank