Fujitsu MHV2080AS, MHV2060AS, MHV2040AS = Supports the CFA Compact Flash Association feature set

Page 159
= 0 = 1
'1' = Supports the IDLE IMMDIATE with UNLOAD FEATURE Reserved
'1' = URG bit supported for WRITE STREAM DMA EXT and
WRITE STREAM EXT
'1' = URG bit supported for READ STREAM DMA EXT and
READ STREAM EXT
'1' = Supports the 64-bit World Wide Name
'1' = Supports the WRITE DMA QUEUED FUA EXT command

5.3 Host Commands

*13 WORD 83

 

Bit 15:

= 0

Bit 14:

= 1

Bit 13: * '1' = FLUSH CACHE EXT command supported.

Bit 12:

'1' = FLUSH CACHE command supported.

Bit 11:

'1' = Device Configuration Overlay feature set supported.

Bit 10:*

'1' = 48 bit LBA feature set.

Bit 9:

'1' = Automatic Acoustic Management feature set.

Bit 8:

'1' = Supports the SET MAX Security extending command.

Bit 7:

Reserved

Bit 6:

'1' = When the power is turned on, spin is started by the SET

 

FEATURES sub-command.

Bit 5:

'1' = Supports the Power-Up In Standby set.

Bit 4:

'1' = Supports the Removable Media Status Notification feature

 

set.

Bit 3:

'1' = Supports the Advanced Power Management feature set.

Bit 2:

'1' = Supports the CFA (Compact Flash Association) feature set.

Bit 1:

'1' = Supports the READ/WRITE DMA QUEUED command.

Bit 0:

'1' = Supports the DOWNLOAD MICROCODE command.

*: Option (customizing)

*14 WORD 84

Bit 15:

Bit 14:

Bit 13:

Bit 12-11:

Bit 10:

Bit 9:

Bit 8:

Bit 7:

C141-E221

5-83

Image 159
Contents Disk Drive Product Manual MHV2080AS, MHV2060AS, MHV2040ASHandling of This Manual For Safe OperationRevision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages Operating EnvironmentConventions Liability Exception This page is intentionally left blank Important Alert Items Important Alert MessagesDamage Interface cable connection This page is intentionally left blank Disk Drive Product Manual Disk Drive Maintenance ManualManual Organization MHV2080ASThis page is intentionally left blank Contents Theory of Device Operation Installation ConditionsInterface Contents101 Write Multiple EXT X’39’ Option customizing Operations Glossary GL-1 Acronyms and Abbreviations AB-1 Index IN-1 Figures IllustrationsExecution example of Read Multiple command Examples of model names and product numbers Tables127 This page is intentionally left blank Device Overview Features Functions and performanceAdaptability Data buffer Error correction and retry by ECCHigh resistance against shock Connection to ATA interfaceMHV2080AS MHV2060AS MHV2040AS Device SpecificationsSpecifications summary Specifications 1Examples of model names and product numbers Model and product numberPower Requirements Input VoltageRipple Current and power dissipation Current Requirements and Power DissipationEnvironmental specifications Environmental SpecificationsCurrent fluctuation Typ. at +5 V when power is turned on Power on/off sequenceShock and Vibration Acoustic noise specificationShock and vibration specification Acoustic NoiseMean time between failures Mtbf Service lifeData assurance in the event of power failure ReliabilityMedia Defects Error RateUnrecoverable read error Positioning errorAdvanced Power Management Advanced Power Management This page is intentionally left blank Device Configuration Device Configuration Read/write circuit System ConfigurationATA interface 2 1 drive connection3 2 drives connection 2 drives configurationInstallation Conditions Dimensions DimensionsMounting Integration Guidance C141-E144Orientation Frame Limitation of mountingPCA Location of breather Ambient temperature Handling cautions Service areaHandling cautions Cable Connections Device connectorFCI Cable connector specificationsCable connector specifications Device connectionJumper Settings Power supply connector CN1Location of setting jumpers Master drive-slave drive setting Factory default setting14 Csel setting Csel setting16 Example 2 of cable select Power up in standby settingTheory of Device Operation Spindle OutlineSubassemblies DiskSpindle motor driver circuit Circuit ConfigurationAir filter Servo circuitPower supply configuration PCA Power-on operation sequence Power-on SequenceSelf-calibration Self-calibration contentsExecution timing of self-calibration Command processing during self-calibrationWrite precompensation Read/write CircuitRead/write preamplifier PreAMP Write circuitRead circuit AGC circuitProgrammable filter circuit Viterbi detection circuit Digital PLL circuitFIR circuit D converter circuitServo control circuit Servo ControlA converter DAC Power amplifierMicroprocessor unit MPU Servo burst capture circuitVCM current sense resistor CSR Driver circuitOuter guard band Data-surface servo formatInner guard band Data areaPhysical sector servo configuration on disk surface Servo frame format Track following operation Actuator motor controlOperation to move the head to the reference cylinder Seek operationSpindle motor control Start modeAcceleration mode Stable rotation modeThis page is intentionally left blank Interface Physical Interface Interface signalsDasp GND Signal assignment on the connectorSignal assignment on the interface connector DA1 PDIAG-, Cblid DA0 DA2Dior MstrDiow StopIordy PdiagCblid DaspLogical Interface 1 I/O registers I/O registersDA2 DA1 DA0 UNC Idnf Command block registersError register X’1F1’ Data register X’1F0’Sector Count register X’1F2’ Features register X’1F1’Sector Number register X’1F3’ Cylinder Low register X’1F4’Cylinder High register X’1F5’ BSY Device/Head register X’1F6’DEV HS3 HS2 HS1 HS0 Status register X’1F7’Interface Command register X’1F7’ Control block registersAlternate Status register X’3F6’ HOB Srst Host CommandsCommand code and parameters Device Control register X’3F6’Command code and parameters 1 Command NameParameter Used EXT Write Multiple FUA EXT Flush Cache EXT Command code and parameters 2Host Commands Command descriptions Host Commands Recalibrate X’10’ to X’1F’ MSB Read Sectors X’20’ or X’21’End head No. / LBA MSB Write Sectors X’30’ or X’31’ 1F7HST Status information 1F6HDH Write Verify X’3C’ Read Verify Sectors X’40’ or X’41’ Seek X’70’ to X’7F’ Diagnostic code Execute Device Diagnostic X’90’Device responds to this command with the result of power-on Initialize Device Parameters X’91’ Download Microcode X’92’ Operation of Download Microcode Standby Immediate X’94’ or X’E0’ Unload Feature Unload Immediate Command Host Commands Standby X’96’ or X’E2’ Idle X’97’ or X’E3’ Interface ’FF’ Check Power Mode X’98’ or X’E5’Sleep X’99’ or X’E6’ Smart X’B0 Features register values subcommands and functions 1 Smart Read LOG Features register values subcommands and functions 2Smart Enable Operations Smart Disable OperationsFeatures register values subcommands and functions 3 ’DB’ Smart ENABLE/DISABLE Auto OFF-LINESmart Return Status Host Commands Format of device attribute value data 1FFFormat of insurance failure threshold value data Attribute ID Data format version numberRaw attribute value Status FlagCurrent attribute value Attribute value for the worst case so far10 Off-line data collection status Self-test execution status11 Self-test execution status 13 Failure prediction capability flag Off-line data collection capability12 Off-line data collection capability Failure prediction capability flagInsurance failure threshold Error logging capability14 Error logging capability Check sumSmart error logging 16 Data format of Smart Summary Error Log 17 Data format of Smart Comprehensive Error Log Command data structureError data structure Total number of drive errorsSelf-test number Smart self-test18 Smart self-test log data format 1FCCurrent span under test 19 Selective self-test log data structureTest span Current LBA under testFeature Flags 20 Selective self-test feature flagsSelective Self-test pending time min Device Configuration Identify Device Configuration XB1Device Configuration Restore Device Configuration FreezeDevice Configuration SET FR = C3h Device Configuration Restore FR = C0hDevice Configuration Freeze Lock FR = C1h Device Configuration Identify FR = C2hInterface 21 Device Configuration Identify data structure 1/2 21 Device Configuration Identify data structure 2/2 Read Multiple X’C4’ Execution example of Read Multiple commandMSB Write Multiple X’C5’ Interface SET Multiple Mode X’C6’ Interface Read DMA X’C8’ or X’C9’ End head No. / LBA MSB Write DMA X’CA’ or X’CB’ Interface Read Buffer X’E4’ Flush Cache X’E7’ Write Buffer X’E8’ Identify Device X’EC’ Identify Device DMA X’EE’ ’3FFF’ 22 Information to be read by Identify Device command 122 Information to be read by Identify Device command 2 3FFF Command without interrupt supports 2, 4, 8 and 16 sectors = Supports the Host Protected Area feature set = Supports the CFA Compact Flash Association feature set Interface Write Stream EXT Interface Host Commands Word Bit Reserved Security level High, 1 Maximum ’CC’ SET Features X’EF’23 Features register values and settable modes ’BB’Data Transfer Mode Advanced Power Management APM Automatic Acoustic Management AAM 24 Contents of Security SET Password data Interface When the master password is selected When the user password is selectedSecurity UNLOCKX’F2’ Interface Security Erase Prepare X’F3’ Security Erase Unit X’F4’ Security Freeze Lock X’F5’ Interface 26 Contents of security password Interface Read Native MAX Address X’F8’ SET MAX Address SET MAX X’F9’SET MAX SET Password FR = 01h SET MAX Lock FR = 02h SET MAX Unlock FR = 03h SET MAX Freeze Lock FR = 04h Host Commands Read Sectors EXT X’24’ Option customizing Description Read DMA EXT X’25’ Option customizing Description Error reporting conditions Read Multiple EXT X’29’ Option customizing Description Read LOG EXT X2F Optional command Customize Description Host Commands Write Sectors EXT X’34’ Option customizing Description Write DMA EXT X’35’ Option customizing Description SET MAX Address EXT X’37’ Option customizing Description SET MAX LBA Write Multiple EXT X’39’ Option customizing Description Write DMA FUA EXT X’3D’ Option customizing Description Write LOG EXT X’3F’ Optional command Customize Description Host Commands Read Verify Sectors EXT X’42 Option customizing Description Write Multiple FUA EXT X’CE’ Option customizing Description Flush Cache EXT X’EA’ Option customizing Description 27 Command code and parameters 1 Error posting27 Command code and parameters 2 Command Protocol PIO Data transferring commands from device to hostExecute Device Diagnostic Initialize Device Parameters Read Sectors Command protocol Protocol for command abort PIO Data transferring commands from host to device Write Sectors command protocol Commands without data transfer Read DMA EXT Write DMA EXT/FUA EXT Indentify Device DMA Other commandsDMA data transfer commands Read Multiple EXT Write Multiple EXT/FUA EXT SleepNormal DMA data transfer Overview Ultra DMA Feature SetPhases of operation Ultra DMA data in commandsInitiating an Ultra DMA data in burst Data in transfer Pausing an Ultra DMA data in burstTerminating an Ultra DMA data in burst Ultra DMA Feature Set Interface Initiating an Ultra DMA data out burst Ultra DMA data out commandsData out transfer Pausing an Ultra DMA data out burstTerminating an Ultra DMA data out burst Interface Ultra DMA CRC rules DIOW-STOP Series termination required for Ultra DMA28 Recommended series termination for Ultra DMA DIOR-HDMARDY-HSTROBETiming PIO data transferPIO data transfer timing Multiword data transfer 10 Multiword DMA data transfer timing mode11 Initiating an Ultra DMA data in burst Ultra DMA data transferStrobe Name Mode CommentMIN MAX 29 Ultra DMA data burst timing requirements 230 Ultra DMA sender and recipient timing requirements Mode Name CommentDD150 at host Sustained Ultra DMA data in burstDstrobe at device DD150 at device Dstrobe at hostHdmardy Host pausing an Ultra DMA data in burstDmarq DmackStop Device terminating an Ultra DMA data in burstHost terminating an Ultra DMA data in burst HostDA0, DA1, DA2 CS0, CS1 16 Initiating an Ultra DMA data out burst Sustained Ultra DMA data out burst Hstrobe at host DD150 at hostHstrobe at device DD150 at device Device pausing an Ultra DMA data out burst Device DMACK- host Stop host DDMARDY- deviceHstrobe host DD150 Host 19 Host terminating an Ultra DMA data out burst Host terminating an Ultra DMA data out burstDevice terminating an Ultra DMA data out burst Dmarq device DMACK- hostDD150 Host Power-on and reset Master and slave devices are present 2-drives configurationOnly master device is present Operations Response to power-on Device Response to the ResetResponse to power-on Response to hardware resetResponse to hardware reset Response to software reset Response to software resetResponse to diagnostic command Response to diagnostic commandActive idle mode Power SavePower save mode Active modeSleep mode Standby modePower commands Defect ProcessingSpare area Alternating processing for defective sectors Sector slip processingTrack slip processing Automatic alternating processing Automatic alternating processingRead-ahead Cache Data buffer structure8MB buffer 8,388,608 bytes Invalidating caching-target data Commands that are targets of cachingCaching operation Data that is a target of cachingSmart Miss-hit Using the read segment bufferSequential hit Full hit Partial hit Invalidation of cached data Command that are targets of cachingWrite Cache Cache operationEnabling and disabling Status report in the event of an errorReset response Caching function when power supply is turned onWrite Cache This page is intentionally left blank Glossary Positioning Power save modeRotational delay PIO Programmed input-outputVCM StatusThis page is intentionally left blank Acronyms and Abbreviations This page is intentionally left blank AAM IndexIndex Host pausing ultra DMA data Read Native MAX Address Read Sectors CommandSurface temperature measurement This page is intentionally left blank Japan Comment FormThis page is intentionally left blank C141-E221-02EN This page is intentionally left blank
Related manuals
Manual 40 pages 57.17 Kb

MHV2060AS, MHV2080AS, MHV2040AS specifications

Fujitsu's MHV series of hard disk drives, specifically the MHV2040AS, MHV2080AS, and MHV2060AS models, are designed to deliver efficient performance and reliability for a range of applications, particularly in desktop computing and entry-level servers. Each of these drives adheres to the Serial ATA (SATA) interface, which ensures compatibility across a wide range of systems and is known for its cost-effectiveness and simplicity.

The MHV2040AS features a storage capacity of 40GB, making it suitable for basic computing tasks including document editing, web browsing, and media playback. The MHV2060AS steps it up with a 60GB capacity, allowing for increased data storage needs while still maintaining a high level of performance. The largest of the trio, the MHV2080AS, offers an impressive 80GB of space, positioning it well for users who require additional room for applications, games, and multimedia files.

All drives in this series are equipped with a rotational speed of 5400 RPM, which strikes a balance between speed and power consumption. This speed is adequate for everyday tasks and allows for quick boot times and file access, making them ideal for home and small office environments. Additionally, the drives feature an average latency of 5.5 milliseconds, contributing to their overall performance in retrieving data.

In terms of technology, the MHV series employs a fluid dynamic bearing (FDB) motor, which not only enhances reliability but also reduces noise levels during operation. The FDB technology helps improve the longevity of the drives by minimizing wear on mechanical components. This characteristic is particularly important for users seeking quieter drives, especially in work environments that require minimal disruption.

The drives also incorporate advanced power management features that significantly reduce power consumption, making them an environmentally friendly choice for users mindful of their carbon footprint. These drives are equipped with energy-saving modes that optimize their performance when not in full use, ensuring lower operational costs and longer lifespan.

Overall, the Fujitsu MHV2040AS, MHV2080AS, and MHV2060AS hard drives provide a solid solution for users looking for dependable storage with a range of capacities to fit their needs. Their performance, combined with noise reduction technologies and energy efficiency, makes them a notable choice for various computing environments, from single-user desktops to small business applications.