IBM SC32-0129-00 manual Locate the line Software to Install

Page 40

Note that the storage agent honors the Tivoli Storage Manager server environment variables DSMSERV_CONFIG and DSMSERV_DIR.

Install the storage agent on a client that has connections to the storage resources on the SAN. The default installation directory is /usr/tivoli/tsm/StorageAgent/bin.

The instructions in this section are shown using the Software Management and Installation Tool (SMIT). You can also use the Install and Update Software Manager (installm).

Note: Throughout this procedure, /dev/cd0 is used for CD-ROM. This may be different in your environment. Loading the storage agent files can take several minutes.

Installation using the SMIT procedure:

1.Be sure you have the information recorded on the forms in “Configuration Information Worksheets” on page 13. This information is required in this procedure.

2.Log in as the root user.

3.Load the storage agent CD into the selected drive.

4.From your desktop window, access SMIT and make selections according to the level of your AIX operating system.

Enter:

smit install_update &

Select:

Install Software

Install Software

5.On the next window, select the device that you are using for the installation. You can enter the drive name in the window or click on List to access the device list.

If you click on List, select the CD drive that you are using for the installation (for example, /dev/cd0).

6.Click on OK.

7.Locate the line Software to Install.

a.To install all components listed in step 8, continue at step 10 on page 23.

b.To selectively install components, click on List for the latest available software packages and continue at step 8.

8.Select the components that you need.

Required components are the storage agent and the message package to be used by the storage agent. The Tivoli Storage Manager device driver is only required when you are using a SCSI device that is not covered by an IBM SCSI device driver. To decide whether to install the device driver package, refer to the support Web site (noted in “Where to Look for Information” on page vi) for a list of devices supported by the Tivoli Storage Manager SCSI device driver.

Table 4. Package and Fileset Names for Installation on AIX 5.1 Platforms

Package and Fileset Names

Description

tivoli.tsm.StorageAgent.rte

Storage agent common functions, sample dsmsta.opt file

 

 

22IBM Tivoli Storage Manager for SAN for AIX: Storage Agent User’s Guide

Image 40
Contents Storage Agent User’s Guide Page Storage Agent User’s Guide Fifth Edition January Contents Page How to Use This Book About This BookWhere to Look for Information IBM Tivoli Storage Manager PublicationsRelated IBM Publications Tivoli Technical Training Support InformationSearching knowledge bases Severity Conventions Used in This Guide Page Changes for IBM Tivoli Storage Manager Version Changes for IBM Tivoli Storage Manager Version 5 ReleaseJanuary OctoberMinimum I/O to Volumes Associated with File Device Class LAN-free for z/OSChanges for IBM Tivoli Storage Manager Version 5 Page Storage Agent Overview SAN LAN-free Client Data Backup Scenario Multi-session No-Query Restore for LAN-free Path Supported Operating Systems PlanningTypes of Environments ACSLS, Scsi and 349X Tape Library Sharing SAN SAN File Device Sharing Using Tivoli SANergy External LibrariesPage Data Migration and Coexistence System Requirements Configuration Information Worksheets Client System Storage agent propertiesDevice information External library ACSLS, 3494, or Scsi drive device namesClient System Drive Shared disk Server System Server propertiesACSLS, 3494, or Scsi library information Drive Shared diskClient Node Information Obtain Device InformationServer System Lanfreecommmethod Tcpip Lanfreetcpserveraddress Overview of Installation and Configuration Tasks Installing and Configuring Tape-LibraryFile-Device Sharing Environments Configuring devices for the storage agent to access Verifying the Network ConnectionClient System Installing Software Tivoli Storage Manager Client WorkstationNext steps. For example Install and Configure the Storage Agent Locate the line Software to Install Devconfig devconfig.out Tape Device Disk Device Configuring Devices for the Storage Agent to Access On page 27 shows the results of completing this stepTape Devices SANDisk Devices OS only Formatting Volumes for LAN-free Data MovementStart the Storage Agent Verify the LAN-free Configuration Determining Whether the Data Movement was LAN-freePage Installing and Configuring External Library Environments Tivoli Storage Manager ServerVerifying the Network Connection Installing and Configuring External Library Environments Servername tsmsrver Install and Configure the Storage Agent Package Name Fileset Names Description Servername tsmsrver Define the storage pool. For example Define path storagnt libmgr1 srctype=server desttype=library Start the Storage Agent Determining Whether the Data Movement was LAN-free Page Appendix A. Administration and Configuration Reference Starting and Stopping the Storage AgentAutomating the Storage Agent Startup Manually Starting and Stopping the Storage AgentFormat Adding Communication Information for the Storage AgentParameters SERVERPAssword ExamplesSERVERName HLAddressRequired Options Storage Agent Options FileAdditional Options COMMTimeout seconds IDLETimeout minutesRESOURCETimeout minutes Msgstacktrace onoffSTAMaxpooledsessions number Tcpadminport numberTHROUGHPUTDatathreshold kilobytespersecond THROUGHPUTTimethreshold minutes Device Configuration File for the Storage AgentUselargebuffers yesno Define Server Appendix B. Legacy Acsls Data Migration and Coexistence Data MigrationMigration New Storage Pool Old Storage Appendix C. Notices Trademarks HacmpAppendix C. Notices Page Glossary Page Glossary Page Index Dsmsta SetstorageserverOptions Page SC32-0129-00

SC32-0129-00 specifications

The IBM SC32-0129-00 is a sophisticated component that plays a vital role in the realm of enterprise computing. Primarily designed for IBM's mid-range systems, it is known for its robust performance and reliability, serving as a critical part of data processing and storage architectures.

One of the main features of the SC32-0129-00 is its advanced input/output capabilities. This component supports a variety of connectivity options, enabling seamless integration within existing IT infrastructures. Its compatibility with multiple IBM systems ensures that organizations can enhance their current setups without needing to overhaul their entire technology stack.

The SC32-0129-00 utilizes cutting-edge technology to optimize data flow and accessibility. With its high-throughput design, it allows for rapid data transfer, facilitating efficient processing and retrieval. This is especially crucial in environments where large amounts of data are generated and need to be analyzed in real-time.

In terms of characteristics, the SC32-0129-00 is built with durability in mind. Its construction adheres to stringent quality standards, which means it can withstand the demands of high-volume operations. This resilience makes it a favored choice among businesses looking to maintain uptime and minimize disruptions.

Additionally, the SC32-0129-00 is designed with scalability in mind. As organizations grow and their data needs expand, this component can easily adapt to accommodate increased workloads. This flexibility is essential for businesses that must evolve with changing market conditions and technological advancements.

Another noteworthy aspect of the SC32-0129-00 is its energy efficiency. In an era where sustainability is paramount, efficient power consumption helps organizations reduce their carbon footprint while lowering operational costs. This aligns with IBM's commitment to creating environmentally friendly solutions.

In summary, the IBM SC32-0129-00 is a critical asset for businesses seeking to enhance their data processing capabilities. With its robust input/output features, high throughput, durability, scalability, and energy efficiency, it is engineered to serve the complex demands of today’s digital landscape. Investing in this component could lead to significant improvements in productivity and performance, making it a valuable addition to any enterprise system.