IBM SC32-0129-00 manual Verify the LAN-free Configuration

Page 47

Manager server is a library client or library manager. If the server is a library client, the storage agent attempts to define itself to the library manager if it is not known to the library manager.

Step 5.2 Verify the LAN-free Configuration

To verify that you have configured your system correctly for LAN-free data movement, perform the following procedure:

1.Specify the DISPLAYLFINFO=YES option in your server options file. This will allow the accounting records and summary table entries to report the storage agent name. Be aware that this option may cause existing outboard automation that relies on the summary table or accounting records not to recognize some activities for a given client. Make sure to consider how this may impact your environment before setting this option.

2.Issue the VALIDATE LANFREE command to determine which destinations for your node are capable of LAN-free data movement. For those nodes that are not capable of LAN-free data movement, this command provides an explanation as to why they are not capable. You can use this information to correct your configuration before proceeding to the next step.

3.Run a backup operation from the client.

4.Ensure the following if you receive a message saying that the backup has failed:

a.The Tivoli Storage Manager server is running. If the Tivoli Storage Manager server is not running, the storage agent will not start.

b.The client, storage agent, and server are communicating with each other as expected.

c.The paths to the drives are correctly defined.

d.All drives in a library have defined paths from the server.

Note: If you retry the backup operation after the first failure, the client attempts to

use the LAN connection for data movement. The client will continue to use

the LAN until the client is stopped and restarted.

Determining Whether the Data Movement was LAN-free

Use the following guidelines to help determine whether the data is moving on the LAN-free path:

v When the data transfers on a LAN-free path, a message displays informing you that the client is starting a session with the storage agent:

ANR0415I Session session number proxied by storage agent name for node your node name

This message confirms that LAN-free data movement has occurred.

vYou can also view the backup report issued when backup processing completes. When LAN-free data movement has occurred, the number of LAN-Free Bytes Transferredis greater than zero.

vMonitor the QUERY SESSION output against the node that is running the LAN-free backup. Review the Bytes Sent and Bytes Received. You can perform this action by using a Tivoli Storage Manager administrative command-line client to login to the Tivoli Storage Manager server and storage agent to verify that the proper sessions have been established. When LAN-free data movement is occurring, a QUERY SESSION on the storage agent should show bytes received (displayed as Bytes Recvd) for the node increasing to the total amount of data being backed up. The QUERY SESSION on the Tivoli Storage Manager

Chapter 3. Installing and Configuring Tape-Library and File-Device Sharing Environments 29

Image 47
Contents Storage Agent User’s Guide Page Storage Agent User’s Guide Fifth Edition January Contents Page About This Book How to Use This BookIBM Tivoli Storage Manager Publications Where to Look for InformationRelated IBM Publications Support Information Tivoli Technical TrainingSearching knowledge bases Severity Conventions Used in This Guide Page October Changes for IBM Tivoli Storage Manager VersionChanges for IBM Tivoli Storage Manager Version 5 Release JanuaryLAN-free for z/OS Minimum I/O to Volumes Associated with File Device ClassChanges for IBM Tivoli Storage Manager Version 5 Page Storage Agent Overview SAN LAN-free Client Data Backup Scenario Multi-session No-Query Restore for LAN-free Path Types of Environments PlanningSupported Operating Systems ACSLS, Scsi and 349X Tape Library Sharing SAN SAN External Libraries File Device Sharing Using Tivoli SANergyPage Data Migration and Coexistence System Requirements ACSLS, 3494, or Scsi drive device names Configuration Information WorksheetsClient System Storage agent properties Device information External libraryDrive Shared disk Client System Drive Shared diskServer System Server properties ACSLS, 3494, or Scsi library informationServer System Obtain Device InformationClient Node Information Lanfreecommmethod Tcpip Lanfreetcpserveraddress File-Device Sharing Environments Installing and Configuring Tape-LibraryOverview of Installation and Configuration Tasks Verifying the Network Connection Configuring devices for the storage agent to accessTivoli Storage Manager Client Workstation Client System Installing SoftwareNext steps. For example Install and Configure the Storage Agent Locate the line Software to Install Devconfig devconfig.out Tape Device Disk Device On page 27 shows the results of completing this step Configuring Devices for the Storage Agent to AccessSAN Tape DevicesStart the Storage Agent OS only Formatting Volumes for LAN-free Data MovementDisk Devices Determining Whether the Data Movement was LAN-free Verify the LAN-free ConfigurationPage Tivoli Storage Manager Server Installing and Configuring External Library EnvironmentsVerifying the Network Connection Installing and Configuring External Library Environments Servername tsmsrver Install and Configure the Storage Agent Package Name Fileset Names Description Servername tsmsrver Define the storage pool. For example Define path storagnt libmgr1 srctype=server desttype=library Start the Storage Agent Determining Whether the Data Movement was LAN-free Page Manually Starting and Stopping the Storage Agent Appendix A. Administration and Configuration ReferenceStarting and Stopping the Storage Agent Automating the Storage Agent StartupParameters Adding Communication Information for the Storage AgentFormat HLAddress SERVERPAsswordExamples SERVERNameAdditional Options Storage Agent Options FileRequired Options Msgstacktrace onoff COMMTimeout secondsIDLETimeout minutes RESOURCETimeout minutesTHROUGHPUTDatathreshold kilobytespersecond Tcpadminport numberSTAMaxpooledsessions number Uselargebuffers yesno Device Configuration File for the Storage AgentTHROUGHPUTTimethreshold minutes Define Server Data Migration Appendix B. Legacy Acsls Data Migration and CoexistenceMigration New Storage Pool Old Storage Appendix C. Notices Hacmp TrademarksAppendix C. Notices Page Glossary Page Glossary Page Dsmsta Setstorageserver IndexOptions Page SC32-0129-00

SC32-0129-00 specifications

The IBM SC32-0129-00 is a sophisticated component that plays a vital role in the realm of enterprise computing. Primarily designed for IBM's mid-range systems, it is known for its robust performance and reliability, serving as a critical part of data processing and storage architectures.

One of the main features of the SC32-0129-00 is its advanced input/output capabilities. This component supports a variety of connectivity options, enabling seamless integration within existing IT infrastructures. Its compatibility with multiple IBM systems ensures that organizations can enhance their current setups without needing to overhaul their entire technology stack.

The SC32-0129-00 utilizes cutting-edge technology to optimize data flow and accessibility. With its high-throughput design, it allows for rapid data transfer, facilitating efficient processing and retrieval. This is especially crucial in environments where large amounts of data are generated and need to be analyzed in real-time.

In terms of characteristics, the SC32-0129-00 is built with durability in mind. Its construction adheres to stringent quality standards, which means it can withstand the demands of high-volume operations. This resilience makes it a favored choice among businesses looking to maintain uptime and minimize disruptions.

Additionally, the SC32-0129-00 is designed with scalability in mind. As organizations grow and their data needs expand, this component can easily adapt to accommodate increased workloads. This flexibility is essential for businesses that must evolve with changing market conditions and technological advancements.

Another noteworthy aspect of the SC32-0129-00 is its energy efficiency. In an era where sustainability is paramount, efficient power consumption helps organizations reduce their carbon footprint while lowering operational costs. This aligns with IBM's commitment to creating environmentally friendly solutions.

In summary, the IBM SC32-0129-00 is a critical asset for businesses seeking to enhance their data processing capabilities. With its robust input/output features, high throughput, durability, scalability, and energy efficiency, it is engineered to serve the complex demands of today’s digital landscape. Investing in this component could lead to significant improvements in productivity and performance, making it a valuable addition to any enterprise system.