Cisco Systems N55M4Q, N5KC5548UPFA manual Required Equipment, Unpacking and Inspecting the Switch

Page 74

Chapter 2 Installing the Cisco Nexus 5000 Series Switches

Preparing for Installation

Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m .

Required Equipment

Before beginning the installation, ensure that you have the following items available:

Four 12-24 or 10-32 screws for attaching slider rails to the rack

Number 1 and number 2 Phillips screwdrivers with torque capability

3/16-inch flat-blade screwdriver

Tape measure and level

ESD wrist strap or other grounding device

Antistatic mat or antistatic foam

The following additional items (not found in the accessory kit) are required to ground the chassis:

Grounding cable (6 AWG recommended), sized according to local and national installation requirements; the required length depends on the proximity of the switch to proper grounding facilities

Crimping tool large enough to accommodate the girth of the lug

Wire-stripping tool

Unpacking and Inspecting the Switch

Caution When handling switch components, wear an ESD strap and handle modules by their handles and carrier edges only. An ESD socket is provided on the chassis. For the ESD socket to be effective, the chassis must be grounded through the power cable, the chassis ground, or the metal-to-metal contact with a grounded rack.

Tip Keep the shipping container in case the chassis requires shipping in the future.

Note The switch is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, contact your customer service representative immediately.

To inspect the shipment, follow these steps:

Step 1 Compare the shipment to the equipment list provided by your customer service representative and verify that you have received all items, including the following:

Grounding lug kit

Rack-mount kit

ESD wrist strap

Cables with connectors

Any optional items ordered

Step 2 Check for damage and report any discrepancies or damage to your customer service representative. Have the following information ready:

Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide

2-4

OL-15902-02

 

 

Image 74
Contents Cisco Nexus 5000 Series Hardware Installation Guide Americas HeadquartersPage Iii Cisco Nexus 5548UP and 5548P Switches Replacing Components Replacing or Installing Power Supplies LEDs D-1 Viii Chapter and Title Description AudienceOrganization Conventions Bewaar Deze InstructiesAviso Instruções Importantes DE Segurança Warnung Wichtige SicherheitshinweiseAvvertenza Importanti Istruzioni Sulla Sicurezza Spara Dessa Anvisningar GEM Disse Anvisninger Xiv Preface Related Documentation Configuration GuidesInstallation and Upgrade Guides Release NotesTroubleshooting Guide Command ReferencesError and System Messages Licensing GuideXviii Cisco Nexus 5500 Platform Switches A P T E RChassis Cisco Nexus 5596UP SwitchFeatures Front View of the Cisco Nexus 5596UP Switch Rear View of the Cisco Nexus 5596UP Switch Expansion ModulesPort Qsfp GEM Port Universal GEM2Layer 3 GEM Ports Power Supply Part Number Power Supply9shows the NXA-PAC-1100W Fan Module 10NXA-PAC-1100W-BTransceivers SFP+ TransceiversSFP Fibre Channel Transceivers Cisco Nexus 5596T SwitchSFP+ Copper Cables Cwdm OpticsFeatures 13 Front View of the Cisco Nexus 5596T Switch 15shows how ports are numbered and grouped by function SFP-10G-LR= SFP-10G-ER= Cisco Nexus 5548UP and 5548P Switches Transceivers and Cables, ID LED N55 M16P Generic Expansion Module ID LED18 Components Used to Install the N55 M16P GEM N55 M8P8FP Generic Expansion Module20 Components Used to Install the N55 M8P8FP GEM N55 M16UP Generic Expansion ModulePower Supplies Data PortsPart Number Power Supply Fan Modules Fail top and OK bottom LEDs Release latch HandleCisco SFP Description Transceivers and CablesTransceivers SFP-10G-SR SFP-10G-LR Cables DS-SFP-FC4G-LWPower Each Transceiver Connector Media Cable Distance Side Cisco Nexus 5000 Platform SwitchesCisco Nexus 5020 Switch StandardTwo power supplies System status LED Five fan modules 28 Cisco Nexus 5020 Switch Rear View 30 Fibre Channel Plus Ethernet Expansion Module Features Fibre Channel Plus Ethernet Expansion ModuleEthernet Expansion Module 31shows the Ethernet and Fibre Channel ports are numberedN5K-M1008 Generic Expansion Module N5K-M1060 Generic Expansion ModuleSix 8-, 4-, 2-, or 1-Gbps Fibre Channel ports 186386 Fault top and OK bottom LEDs Handle Release lever Fan module LED Captive screw Transceivers Cisco Nexus 5010 Switch Two power supplies System status LED Two fan modules N5K-M1404 Generic Expansion Module, N5K-M1404 Generic Expansion Module 45 N5K-M1404 Generic Expansion ModuleN5K-M1600 Generic Expansion Module 46 Front of the N5K-M1404 GEM48 N5K-M1008 GEM 51shows how the ports are numbered on this module 192241 192243 55 Power Supply for the Cisco Nexus 5010 Switch Handle Fan module LED Model Description Overview Cisco Nexus 5000 Platform Switches Installing the Cisco Nexus 5000 Series Switches Chassis Weight Preparing for InstallationInstallation Options with Racks and Cabinets Airflow DirectionInstallation Guidelines Unpacking and Inspecting the Switch Required EquipmentQuantity Part Description Installing the SwitchInstalling a Cisco Nexus 5596 Switch Attaching Rack-Mount Brackets to the Cisco Nexus 5596 Switch Installing the Slider Rails Sliding the Chassis Into the Rack Installing the Cisco Nexus 5548 Switch Step Installing the Cisco Nexus 5020 Switch Cisco Nexus 5020 Switch Rack-Mount Kit Installing the Slider Rails 10 Attaching the Switch to the Rack Installing the Cisco Nexus 5010 Switch 12 Installing the Slider Rails Grounding the Switch Proper Grounding PracticesEnvironment Severity Level Grounding Recommendations Preventing Electrostatic Discharge Damage 186482 Establishing the System Ground Required Tools and EquipmentGrounding the Cisco Nexus 5500 Series Chassis 239272 Grounding the Cisco Nexus 5000 Series Chassis Starting the Switch 239212 OL-15902-02 OL-15902-02 Connecting the Switch Connecting to the Console Port Preparing for Network ConnectionsConnecting to the Ethernet Connector Port Installing an SFP+ Transceiver Connecting to an Ethernet PortInstalling and Replacing SFP+ Transceivers Replacing an SFP+ Transceiver Installing Cables into SFP+ Transceivers Installing a Cable into an SFP+ TransceiverConnecting to a Fibre Channel Port Replacing a Cable for an SFP+ TransceiverRemoving an SFP Transceiver Removing and Installing SFP TransceiversInstalling an SFP Transceiver Alternate Removal Method for Bale Clasp SFP Transceivers Removing and Installing Cables into SFP Transceivers Installing a Cable into an SFP TransceiverMaintaining SFP Transceivers and Fiber-Optic Cables Removing a Cable from an SFP TransceiverOL-15902-01 Replacing an I/O Module for a Cisco Nexus 5548 Switch Replacing ComponentsRemoving an I/O Module Product ID on a Layer 3 I/O ModuleRemoving a Fan Tray from the I/O Module in the Chassis Installing an I/O Module Removing the I/O Module from the ChassisReplacing Expansion Modules Positioning the Module in the Cisco Nexus 5548 Chassis Positioning the Module in the Cisco Nexus 5020 Chassis Replacing or Installing Power Supplies Positioning the Module in the Cisco Nexus 5010 ChassisRemoving a Power Supply Removing the Power Supply from a Cisco Nexus 5596 SwitchRemoving the Power Supply from a Cisco Nexus 5548 Switch Installing a Power Supply 11 Removing the Power Supply from a Cisco Nexus 5010 SwitchWiring a DC Power Connector Removing a Fan Module, Installing a Fan Module, Replacing a Fan ModuleInstalling a Fan Module Removing a Fan Module14 Installing a Fan Module in a Cisco Nexus 5548 Chassis 15 Installing a Fan Module in a Cisco Nexus 5020 Chassis Replacing Components OL-15902-01 Cabinet and Rack Requirements General Requirements for Cabinets and RacksCable Management Guidelines Requirements Specific to Perforated CabinetsSwitch Specifications Description SpecificationProperty Cisco Nexus 5020 Switch Cisco Nexus 5010 Switch Environmental SpecificationsProperty Cisco Nexus 5596 Switch Cisco Nexus 5548 Switch Specifications for the Cisco Nexus 5596 Power Supply Expansion Module SpecificationsPower Specifications AC Power Supply Properties SpecificationSpecifications for the Cisco Nexus 5548 Power Supply DC Power Supply Properties SpecificationSpecifications for the Cisco Nexus 5020 Power Supplies Specifications for the Cisco Nexus 5010 Power SupplyTransceiver Specifications Description Short RangeParameter Symbol Minimum Maximum Unit Description Short WavelengthOL-15902-01 Cable and Port Specifications Console CablePin Signal Cable RJ-45 Connector PinoutsSignal Name P1, P1-45 Pins P2, DB-9 Pins Console PortDescription Feet Meters Illustration Supported Power Cords and PlugsLength CAB-9K10A-IT CAB-9K10A-AU VSCC15 CAB-9K10A-SW CAB-N5K6A-NA Jumper Power Cord SS10AFigure C-16 CAB-C13-C14-JMPR, Jumper Power Cord LEDs Status Description Chassis and Module LED DescriptionsComponent Conditions Indicated by the Power Supply LEDs Power Supply Condition Green AmberEthernet and Fibre Channel LEDs Port LEDsEthernet Port LEDs Link State LED StateOverview Snmp TrapsInstallation Best Practices Switch Hardware Best PracticesPower Supply Conditions Switch Operation Best PracticesPower Supply Condition Power LED Status Fail LED Status Cisco Nexus 5000 Series Hardware Installation Guide Accessory Kits Cisco Nexus 5596UP and 5596T Switch Accessory KitCisco Nexus 5020 Switch Accessory Kit Cisco Nexus 5010 Switch Accessory KitOL-15902-02-xx Cisco Nexus 5000 Series Hardware Installation Guide Site Planning and Maintenance Records Site Preparation ChecklistTask No Planning Activity Verified By Time Date Contact and Site Information Chassis and Module Information Slot Module Type Module Serial Number SupervisorNumerics IN-2 IN-3 IN-4
Related manuals
Manual 36 pages 49.44 Kb