Cisco Systems N5KC5548UPFA, N55M4Q manual Installing the Slider Rails

Page 83

Chapter 2 Installing the Cisco Nexus 5000 Series Switches

Installing the Switch

Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m .

Step 2 Install the rack-mount guides on the switch as follows:

a.Position one of the rack-mount brackets against the side of the switch and align the screw holes as shown in Figure 2-7. Then attach the bracket to the switch with two of the flat-head M4 screws.

b.Repeat with the other rack-mount bracket on the other side of the switch.

Step 3 Attach the slider rails to the rack as shown in Figure 2-8. Use two 12-24 screws or two 10-32 screws, depending on the rack rail thread type. For racks with square holes, insert the 12-24 cage nuts in position behind the mounting holes in the slider rails.

a.Repeat with the other slider rail on the other side of the rack.

b.Use the tape measure and level to verify that the rails are horizontal and at the same height.

Figure 2-8 Installing the Slider Rails

2

2

1

1

239034

1

Slider rail with screw holes aligned to screw holes in rack

2

Two customer supplied 12-24 or 10-32 screws used to attach each slider rail to the rack

Step 4 Insert the switch into the rack and attach it as follows:

a.Using both hands, position the switch with the back of the switch between the front posts of the rack.

b.Align the two rack-mount guides on either side of the switch with the slider rails installed in the rack. Slide the rack-mount guides onto the slider rails, and then gently slide the switch all the way into the rack. See Figure 2-9. If the switch does not slide easily, try realigning the rack-mount guides on the slider rails.

 

 

Cisco Nexus 5500 Platform and Cisco Nexus 5000 Platform Hardware Installation Guide

 

 

 

 

 

 

OL-15902-02

 

 

2-13

 

 

 

 

 

Image 83
Contents Americas Headquarters Cisco Nexus 5000 Series Hardware Installation GuidePage Iii Cisco Nexus 5548UP and 5548P Switches Replacing Components Replacing or Installing Power Supplies LEDs D-1 Viii Chapter and Title Description AudienceOrganization Bewaar Deze Instructies ConventionsAviso Instruções Importantes DE Segurança Warnung Wichtige SicherheitshinweiseAvvertenza Importanti Istruzioni Sulla Sicurezza Spara Dessa Anvisningar GEM Disse Anvisninger Xiv Preface Release Notes Configuration GuidesInstallation and Upgrade Guides Related DocumentationLicensing Guide Command ReferencesError and System Messages Troubleshooting GuideXviii A P T E R Cisco Nexus 5500 Platform SwitchesChassis Cisco Nexus 5596UP SwitchFeatures Front View of the Cisco Nexus 5596UP Switch Expansion Modules Rear View of the Cisco Nexus 5596UP SwitchPort Universal GEM2 Port Qsfp GEMLayer 3 GEM Ports Part Number Power Supply Power Supply9shows the NXA-PAC-1100W 10NXA-PAC-1100W-B Fan ModuleSFP+ Transceivers TransceiversCwdm Optics Cisco Nexus 5596T SwitchSFP+ Copper Cables SFP Fibre Channel TransceiversFeatures 13 Front View of the Cisco Nexus 5596T Switch 15shows how ports are numbered and grouped by function SFP-10G-LR= SFP-10G-ER= Cisco Nexus 5548UP and 5548P Switches Transceivers and Cables, ID LED ID LED N55 M16P Generic Expansion ModuleN55 M8P8FP Generic Expansion Module 18 Components Used to Install the N55 M16P GEMN55 M16UP Generic Expansion Module 20 Components Used to Install the N55 M8P8FP GEMData Ports Power SuppliesPart Number Power Supply Fail top and OK bottom LEDs Release latch Handle Fan ModulesCisco SFP Description Transceivers and CablesTransceivers SFP-10G-SR SFP-10G-LR DS-SFP-FC4G-LW CablesStandard Cisco Nexus 5000 Platform SwitchesCisco Nexus 5020 Switch Power Each Transceiver Connector Media Cable Distance SideTwo power supplies System status LED Five fan modules 28 Cisco Nexus 5020 Switch Rear View Fibre Channel Plus Ethernet Expansion Module 30 Fibre Channel Plus Ethernet Expansion Module Features31shows the Ethernet and Fibre Channel ports are numbered Ethernet Expansion ModuleN5K-M1060 Generic Expansion Module N5K-M1008 Generic Expansion ModuleSix 8-, 4-, 2-, or 1-Gbps Fibre Channel ports 186386 Fault top and OK bottom LEDs Handle Release lever Fan module LED Captive screw Transceivers Cisco Nexus 5010 Switch Two power supplies System status LED Two fan modules N5K-M1404 Generic Expansion Module, 45 N5K-M1404 Generic Expansion Module N5K-M1404 Generic Expansion Module46 Front of the N5K-M1404 GEM N5K-M1600 Generic Expansion Module48 N5K-M1008 GEM 51shows how the ports are numbered on this module 192241 192243 55 Power Supply for the Cisco Nexus 5010 Switch Handle Fan module LED Model Description Overview Cisco Nexus 5000 Platform Switches Installing the Cisco Nexus 5000 Series Switches Airflow Direction Preparing for InstallationInstallation Options with Racks and Cabinets Chassis WeightInstallation Guidelines Required Equipment Unpacking and Inspecting the SwitchQuantity Part Description Installing the SwitchInstalling a Cisco Nexus 5596 Switch Attaching Rack-Mount Brackets to the Cisco Nexus 5596 Switch Installing the Slider Rails Sliding the Chassis Into the Rack Installing the Cisco Nexus 5548 Switch Step Installing the Cisco Nexus 5020 Switch Cisco Nexus 5020 Switch Rack-Mount Kit Installing the Slider Rails 10 Attaching the Switch to the Rack Installing the Cisco Nexus 5010 Switch 12 Installing the Slider Rails Proper Grounding Practices Grounding the SwitchEnvironment Severity Level Grounding Recommendations Preventing Electrostatic Discharge Damage 186482 Required Tools and Equipment Establishing the System GroundGrounding the Cisco Nexus 5500 Series Chassis 239272 Grounding the Cisco Nexus 5000 Series Chassis Starting the Switch 239212 OL-15902-02 OL-15902-02 Connecting the Switch Preparing for Network Connections Connecting to the Console PortConnecting to the Ethernet Connector Port Installing an SFP+ Transceiver Connecting to an Ethernet PortInstalling and Replacing SFP+ Transceivers Replacing an SFP+ Transceiver Installing a Cable into an SFP+ Transceiver Installing Cables into SFP+ TransceiversReplacing a Cable for an SFP+ Transceiver Connecting to a Fibre Channel PortRemoving an SFP Transceiver Removing and Installing SFP TransceiversInstalling an SFP Transceiver Alternate Removal Method for Bale Clasp SFP Transceivers Installing a Cable into an SFP Transceiver Removing and Installing Cables into SFP TransceiversRemoving a Cable from an SFP Transceiver Maintaining SFP Transceivers and Fiber-Optic CablesOL-15902-01 Replacing Components Replacing an I/O Module for a Cisco Nexus 5548 SwitchProduct ID on a Layer 3 I/O Module Removing an I/O ModuleRemoving a Fan Tray from the I/O Module in the Chassis Removing the I/O Module from the Chassis Installing an I/O ModuleReplacing Expansion Modules Positioning the Module in the Cisco Nexus 5548 Chassis Positioning the Module in the Cisco Nexus 5020 Chassis Positioning the Module in the Cisco Nexus 5010 Chassis Replacing or Installing Power SuppliesRemoving the Power Supply from a Cisco Nexus 5596 Switch Removing a Power SupplyRemoving the Power Supply from a Cisco Nexus 5548 Switch 11 Removing the Power Supply from a Cisco Nexus 5010 Switch Installing a Power SupplyWiring a DC Power Connector Replacing a Fan Module Removing a Fan Module, Installing a Fan Module,Removing a Fan Module Installing a Fan Module14 Installing a Fan Module in a Cisco Nexus 5548 Chassis 15 Installing a Fan Module in a Cisco Nexus 5020 Chassis Replacing Components OL-15902-01 General Requirements for Cabinets and Racks Cabinet and Rack RequirementsRequirements Specific to Perforated Cabinets Cable Management GuidelinesDescription Specification Switch SpecificationsProperty Cisco Nexus 5020 Switch Cisco Nexus 5010 Switch Environmental SpecificationsProperty Cisco Nexus 5596 Switch Cisco Nexus 5548 Switch AC Power Supply Properties Specification Expansion Module SpecificationsPower Specifications Specifications for the Cisco Nexus 5596 Power SupplyDC Power Supply Properties Specification Specifications for the Cisco Nexus 5548 Power SupplySpecifications for the Cisco Nexus 5010 Power Supply Specifications for the Cisco Nexus 5020 Power SuppliesDescription Short Range Transceiver SpecificationsDescription Short Wavelength Parameter Symbol Minimum Maximum UnitOL-15902-01 Console Cable Cable and Port SpecificationsConsole Port Cable RJ-45 Connector PinoutsSignal Name P1, P1-45 Pins P2, DB-9 Pins Pin SignalDescription Feet Meters Illustration Supported Power Cords and PlugsLength CAB-9K10A-IT CAB-9K10A-AU VSCC15 CAB-9K10A-SW CAB-N5K6A-NA SS10A Jumper Power CordFigure C-16 CAB-C13-C14-JMPR, Jumper Power Cord LEDs Status Description Chassis and Module LED DescriptionsComponent Power Supply Condition Green Amber Conditions Indicated by the Power Supply LEDsLink State LED State Port LEDsEthernet Port LEDs Ethernet and Fibre Channel LEDsSnmp Traps OverviewSwitch Operation Best Practices Switch Hardware Best PracticesPower Supply Conditions Installation Best PracticesPower Supply Condition Power LED Status Fail LED Status Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5596UP and 5596T Switch Accessory Kit Accessory KitsCisco Nexus 5010 Switch Accessory Kit Cisco Nexus 5020 Switch Accessory KitOL-15902-02-xx Cisco Nexus 5000 Series Hardware Installation Guide Site Preparation Checklist Site Planning and Maintenance RecordsTask No Planning Activity Verified By Time Date Contact and Site Information Slot Module Type Module Serial Number Supervisor Chassis and Module InformationNumerics IN-2 IN-3 IN-4
Related manuals
Manual 36 pages 49.44 Kb