Cisco Systems 5000 Series manual Port Level LED’s, Link State LED State

Page 42

Chapter 1 Product Overview

Nexus 5010 Switch

Se n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a ck @ c i s c o . c o m

Table 1-6 LEDs for the Cisco Nexus 5010 Switch (continued)

LED

Location

Function

Color

Status

Description

 

 

 

 

 

 

PSU Status

Power supply

PSU Health

Green

OFF

No AC power to power supply

Indicators

(front)

(multi color)

 

 

 

 

Solid On

Power supply on and OK

 

 

 

 

 

 

 

 

 

 

 

 

 

Amber

Solid On

Power supply failures, over volt-

 

 

 

 

 

age, over current, over temperature

 

 

 

 

 

 

 

 

 

 

1 Hz

AC present, 3.3VSB on,

 

 

 

 

blinking

PSU is off

 

 

 

 

 

 

 

 

 

 

OFF

Operating normally

 

 

 

 

 

 

GEM Cards

back of chassis

An indicator

Green

On

GEM card is operating

Health Indicator

 

to show

 

 

normally

 

 

there is a

 

 

 

 

 

 

 

 

 

 

fault with

 

 

 

 

 

Amber

Solid on

A fault has occurred on

 

 

any one of

 

 

the GEM card.

 

 

the GEM

 

 

 

 

 

card

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Port Level LED’s

There are twenty to twenty-six port activity LEd’s on switch depending on whether the GEM is a Fibre Channel or 10GE. The table summarizes the behavior of the port LED’s.

Link State

LED State

Notes

 

 

 

Link Down

OFF

 

 

 

 

POST failed on port

AMBER blinking yellow

 

 

 

 

Administrative disabled

AMBER_ON

Depending on the product you look at, the

 

 

LED could be off, or solid amber.

 

 

 

Link Up,

GREEN_ON

Blinks based on network activity

port in STP forwarding

 

 

state

 

 

 

 

 

Supported SFP Transceivers

The Cisco Nexus 5010 switch supports both SFP+ Ethernet transceivers and SFP Fibre Channel transceivers.

 

Cisco Nexus 5000 Series Hardware Installation Guide

1-28

OL-15902-01

Image 42
Contents Cisco Nexus 5000 Series Hardware Installation Guide Americas HeadquartersCisco Nexus 5000 Series Hardware Installation Guide Iii SFP+ Copper Cables Cable Management Guidelines Switch Specifications Chassis and Module Information D-4 Overview E-1 Audience OrganizationChapter Title Description Conventions Chapter Title DescriptionWarnung Wichtige Sicherheitshinweise Avvertenza Importanti Istruzioni Sulla SicurezzaAviso Instruções Importantes DE Segurança Guarde Estas InstruçõesGEM Disse Anvisninger Xii Xiii Related Documentation Nexus 5020 Switch FeaturesTwo power supplies Five fan modules ChassisCisco Nexus 5020 Switch Rear View Internal cross connect ports Network management ports Expansion Modules Fibre Channel Plus Ethernet Expansion ModuleStatus Description Ethernet Expansion Module Six 10-Gigabit Ethernet ports Module LEDN5K-M1008 LEDPorts Power Supply 13 Power Supply for the Cisco Nexus 5020 SwitchPower Supply Condition Power LED Status Fail LED Status Fan Module15 Cisco Nexus 5020 Fan Module LED Descriptions Location Function Color Status DescriptionLED SFP+ Copper Cables Supported SFP TransceiversSFP+ Transceivers ModelNexus 5010 Switch SFP Fiber Channel TransceiversModel Description 17shows the front of the Cisco Nexus 5010 switch 18shows a close-up view of the front of the switch Product Overview Nexus 5010 Switch 20 Cisco Nexus 5010 Switch Rear View Close-up N5K-M1404 22 N5K-M1404 Gatos Expansion ModuleN5K-M1600 23 Front of the N5K-M1404 GEM25 N5K-M1008 GEM 192241 192242 30 Power Supply for the Cisco Nexus 5010 Switch 31 Blank Power Supply Filler Panel Fan module LED Port Level LED’s Link State LED StateDS-SFP-FC4G-SW Product Overview Nexus 5010 Switch Installing the Cisco Nexus 5000 Switch Chassis Weight Preparing for InstallationInstallation Options Airflow ConsiderationsInstallation Guidelines Unpacking and Inspecting the Switch Required EquipmentQuantity Part Description Slider railsFront rack-mount bracket Slider rail Rack-mount guides Installing the Slider Rails Installing the Cisco Nexus 5010 Chassis in a Cabinet or Rack 273161 Grounding the System Proper Grounding PracticesEnvironment Level Grounding Recommendations Preventing Electrostatic Discharge Damage Attaching the ESD Wrist Strap to the System Ground Lug Screw Establishing the System Ground Required Tools and EquipmentGrounding the Chassis Location of System Ground on a Cisco Nexus 5000 Switch Starting the Switch Removing and Installing Components Removing and Installing Expansion Modules Installing an Expansion ModuleRemoving an Expansion Module Positioning the Module in the Cisco Nexus 5020 ChassisRemoving and Installing Power Supplies Removing a Power SupplyInstalling a Power Supply 11 Removing the Power Supply for the Cisco Nexus 5020 switchRemoving and Installing the Fan Module 13 Fan Module for the Cisco Nexus 5020 switch Removing a Fan ModuleRemoving the Cisco Nexus 5000 Switch Installing a Fan ModuleRepacking the Cisco Nexus 5000 Switch for Return Shipment Connecting the Cisco Nexus 5000 Switch Connecting to the Console Port Preparing for Network ConnectionsConnecting to the Ethernet Connector Port Installing an SFP+ Transceiver Connecting to an Ethernet PortRemoving and Installing SFP+ Transceivers Removing an SFP+ TransceiverAlternate Removal Method for Bale Clasp SFP+ Transceivers Removing and Installing Cables into SFP+ Transceivers Installing a Cable into an SFP+ TransceiverRemoving a Cable from an SFP+ Transceiver Installing an SFP Transceiver Connecting to a Fibre Channel PortRemoving and Installing SFP Transceivers Maintaining SFP+ Transceivers and CablesRemoving an SFP Transceiver Removing and Installing Cables into SFP Transceivers Installing a Cable into an SFP TransceiverConnecting the LC-Type Cable to a Fibre Channel Port Removing a Cable from an SFP TransceiverMaintaining SFP Transceivers and Fiber-Optic Cables Cisco Nexus 5000 Series Hardware Installation Guide Cabinet and Rack Requirements General Requirements for Cabinets and RacksRequirements Specific to Perforated Cabinets Rittal CorporationCable Management Guidelines Requirements Specific to Solid-Walled CabinetsRequirements Specific to Standard Open Racks Cisco Nexus 5000 Series Hardware Installation Guide Switch Specifications Description SpecificationExpansion Module Specifications Power SpecificationsSpecifications for the Cisco Nexus 5020 Power Supply Specifications for the Cisco Nexus 5010 Power Supply Power Supply LED IndicatorsCondition Power LED Status Green Fail LED Status Amber Transceiver Specifications Parameter Symbol Min Max UnitDescription Short Range Description Short Wavelength MMFCisco Nexus 5000 Series Hardware Installation Guide Accessory Kit for the Cisco Nexus 5020 Switch Accessory Kit for the Cisco Nexus 5010 SwitchCable RJ-45 Connector Pinouts Signal Name P1, P1-45 Pins P2, DB-9 PinsConsole Cable Pin Signal Console PortConsole Port Pinouts Length Supported Power Cords and PlugsPower Cords Description Feet Meters IllustrationAC Power Cord Illustrations CAB-9K10A-UKCAB-9K10A-AU Plug VSCC15 BKR CAB-9K12A-NA Jumper Power Cord Figure C-16 CAB-C13-C14-JMPR, Jumper Power CordSite Planning and Maintenance Records Site Preparation ChecklistTask No Planning Activity Verified By Time Date Contact and Site Information Chassis and Module Information Slot Module Type Module Serial Number SupervisorSwitch Hardware Best Practices OverviewSnmp Traps Installation Best Practices Switch Operation Best PracticesInitialization Best Practices Numerics IN-2 IN-3 IN-4

5000 Series specifications

Cisco Systems 5000 Series is a comprehensive line of network switches designed to provide robust performance, high scalability, and exceptional flexibility for various enterprise applications. This switch series is ideally suited for environments such as data centers and large-scale enterprise networks, addressing the demands of modern networking by delivering high-speed connectivity along with advanced features.

One of the standout features of the Cisco 5000 Series is its support for hybrid environments, allowing deployment in both on-premises data centers and cloud-based architectures. With enhanced support for modern networking paradigms, such as Software-Defined Networking (SDN), the switches facilitate seamless integration into existing infrastructure while optimizing resource utilization. Cisco's Application Centric Infrastructure (ACI) technology enhances application performance and availability across diverse workloads and applications.

The 5000 Series delivers superior performance with fixed and modular configurations tailored to different operational demands. This flexibility allows businesses to select from various models that best fit their specific needs, whether they require high-density 10, 25, 40, or 100 Gigabit Ethernet connectivity. The series supports high throughput and low latency, making it ideal for data-intensive applications such as virtualization and real-time data processing.

High availability is another critical aspect of the Cisco 5000 Series, which incorporates redundant hardware components and advanced configuration options. Features like Hot Swappable Power Supplies and Fans ensure minimal downtime during maintenance activities. Additionally, these switches come equipped with comprehensive features for network visibility and monitoring, including Cisco’s In-Service Software Upgrade (ISSU) capabilities that allow for continuous operations during updates.

Security is paramount in today’s networking landscape, and the Cisco 5000 Series is equipped with advanced security features. These include support for Virtual LANs (VLANs), Access Control Lists (ACLs), and advanced threat detection mechanisms. Cisco Identity Services Engine (ISE) integration provides granular control over user access and policy enforcement, creating a secure environment for sensitive data.

In summary, the Cisco Systems 5000 Series is a powerful solution designed for modern networking challenges, featuring hybrid deployment capabilities, robust performance metrics, high availability, and advanced security protocols. Businesses deploying these switches benefit from scalability and flexibility, ensuring their network can adapt to evolving demands while maintaining optimal performance and security.