Cisco Systems 5000 Series manual Cabinet and Rack Requirements

Page 83

Se n d d o c u m e n t a t i o n c o m m e n t s t o n ex u s 5 k d o c s @ c i s c o . c o m

A P P E N D I X A

Cabinet and Rack Installation

This appendix provides the requirements for cabinet and rack installation and includes the following sections:

Cabinet and Rack Requirements, page A-1.

Cable Management Guidelines, page A-3

Cabinet and Rack Requirements

This section provides the requirements for the following types of cabinets and racks, assuming an external ambient air temperature range of 0 to 104oF (0 to 40oC):

Standard perforated cabinets

Solid-walled cabinets with a roof fan tray (bottom to top cooling)

Standard open racks

Note If you are selecting an enclosed cabinet, we recommend one of the thermally validated types: standard perforated or solid-walled with a fan tray.

Note Do not use racks that have obstructions (such as power strips), because the obstructions could impair access to field-replaceable units (FRUs).

General Requirements for Cabinets and Racks

The cabinet or rack must be one of the following types:

Standard 19-in. (48.3 cm) (four-post EIA cabinet or rack, with mounting rails that conform to English universal hole spacing per section 1 of ANSI/EIA-310-D-1992. See the “Requirements Specific to Perforated Cabinets” section on page A-2and the “Requirements Specific to Solid-Walled Cabinets” section on page A-3.

The cabinet or rack must also meet the following requirements:

The minimum vertical rack space per 5020 chassis must be two RU (rack units), equal to 3.50 inches (8.9 cm).

Cisco Nexus 5000 Series Hardware Installation Guide

 

OL-15902-01

A-1

 

Image 83
Contents Americas Headquarters Cisco Nexus 5000 Series Hardware Installation GuideCisco Nexus 5000 Series Hardware Installation Guide Iii SFP+ Copper Cables Cable Management Guidelines Switch Specifications Chassis and Module Information D-4 Overview E-1 Chapter Title Description AudienceOrganization Chapter Title Description ConventionsAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseGuarde Estas Instruções Aviso Instruções Importantes DE SegurançaGEM Disse Anvisninger Xii Xiii Related Documentation Features Nexus 5020 SwitchChassis Two power supplies Five fan modulesCisco Nexus 5020 Switch Rear View Internal cross connect ports Network management ports Status Description Expansion ModulesFibre Channel Plus Ethernet Expansion Module Six 10-Gigabit Ethernet ports Module LED Ethernet Expansion ModuleLED N5K-M1008Ports 13 Power Supply for the Cisco Nexus 5020 Switch Power SupplyFan Module Power Supply Condition Power LED Status Fail LED Status15 Cisco Nexus 5020 Fan Module Location Function Color Status Description LED DescriptionsLED Model Supported SFP TransceiversSFP+ Transceivers SFP+ Copper CablesModel Description Nexus 5010 SwitchSFP Fiber Channel Transceivers 17shows the front of the Cisco Nexus 5010 switch 18shows a close-up view of the front of the switch Product Overview Nexus 5010 Switch 20 Cisco Nexus 5010 Switch Rear View Close-up 22 N5K-M1404 Gatos Expansion Module N5K-M140423 Front of the N5K-M1404 GEM N5K-M160025 N5K-M1008 GEM 192241 192242 30 Power Supply for the Cisco Nexus 5010 Switch 31 Blank Power Supply Filler Panel Fan module LED Link State LED State Port Level LED’sDS-SFP-FC4G-SW Product Overview Nexus 5010 Switch Installing the Cisco Nexus 5000 Switch Airflow Considerations Preparing for InstallationInstallation Options Chassis WeightInstallation Guidelines Required Equipment Unpacking and Inspecting the SwitchSlider rails Quantity Part DescriptionFront rack-mount bracket Slider rail Rack-mount guides Installing the Slider Rails Installing the Cisco Nexus 5010 Chassis in a Cabinet or Rack 273161 Proper Grounding Practices Grounding the SystemEnvironment Level Grounding Recommendations Preventing Electrostatic Discharge Damage Attaching the ESD Wrist Strap to the System Ground Lug Screw Required Tools and Equipment Establishing the System GroundGrounding the Chassis Location of System Ground on a Cisco Nexus 5000 Switch Starting the Switch Removing and Installing Components Installing an Expansion Module Removing and Installing Expansion ModulesPositioning the Module in the Cisco Nexus 5020 Chassis Removing an Expansion ModuleRemoving a Power Supply Removing and Installing Power Supplies11 Removing the Power Supply for the Cisco Nexus 5020 switch Installing a Power SupplyRemoving and Installing the Fan Module Removing a Fan Module 13 Fan Module for the Cisco Nexus 5020 switchInstalling a Fan Module Removing the Cisco Nexus 5000 SwitchRepacking the Cisco Nexus 5000 Switch for Return Shipment Connecting the Cisco Nexus 5000 Switch Preparing for Network Connections Connecting to the Console PortConnecting to the Ethernet Connector Port Removing an SFP+ Transceiver Connecting to an Ethernet PortRemoving and Installing SFP+ Transceivers Installing an SFP+ TransceiverAlternate Removal Method for Bale Clasp SFP+ Transceivers Removing a Cable from an SFP+ Transceiver Removing and Installing Cables into SFP+ TransceiversInstalling a Cable into an SFP+ Transceiver Maintaining SFP+ Transceivers and Cables Connecting to a Fibre Channel PortRemoving and Installing SFP Transceivers Installing an SFP TransceiverRemoving an SFP Transceiver Installing a Cable into an SFP Transceiver Removing and Installing Cables into SFP TransceiversRemoving a Cable from an SFP Transceiver Connecting the LC-Type Cable to a Fibre Channel PortMaintaining SFP Transceivers and Fiber-Optic Cables Cisco Nexus 5000 Series Hardware Installation Guide General Requirements for Cabinets and Racks Cabinet and Rack RequirementsRittal Corporation Requirements Specific to Perforated CabinetsRequirements Specific to Standard Open Racks Cable Management GuidelinesRequirements Specific to Solid-Walled Cabinets Cisco Nexus 5000 Series Hardware Installation Guide Description Specification Switch SpecificationsSpecifications for the Cisco Nexus 5020 Power Supply Expansion Module SpecificationsPower Specifications Condition Power LED Status Green Fail LED Status Amber Specifications for the Cisco Nexus 5010 Power SupplyPower Supply LED Indicators Description Short Range Transceiver SpecificationsParameter Symbol Min Max Unit MMF Description Short WavelengthCisco Nexus 5000 Series Hardware Installation Guide Accessory Kit for the Cisco Nexus 5010 Switch Accessory Kit for the Cisco Nexus 5020 SwitchConsole Cable Cable RJ-45 Connector PinoutsSignal Name P1, P1-45 Pins P2, DB-9 Pins Console Port Pinouts Pin SignalConsole Port Description Feet Meters Illustration Supported Power Cords and PlugsPower Cords LengthCAB-9K10A-UK AC Power Cord IllustrationsCAB-9K10A-AU Plug VSCC15 BKR CAB-9K12A-NA Figure C-16 CAB-C13-C14-JMPR, Jumper Power Cord Jumper Power CordSite Preparation Checklist Site Planning and Maintenance RecordsTask No Planning Activity Verified By Time Date Contact and Site Information Slot Module Type Module Serial Number Supervisor Chassis and Module InformationSnmp Traps Switch Hardware Best PracticesOverview Initialization Best Practices Installation Best PracticesSwitch Operation Best Practices Numerics IN-2 IN-3 IN-4

5000 Series specifications

Cisco Systems 5000 Series is a comprehensive line of network switches designed to provide robust performance, high scalability, and exceptional flexibility for various enterprise applications. This switch series is ideally suited for environments such as data centers and large-scale enterprise networks, addressing the demands of modern networking by delivering high-speed connectivity along with advanced features.

One of the standout features of the Cisco 5000 Series is its support for hybrid environments, allowing deployment in both on-premises data centers and cloud-based architectures. With enhanced support for modern networking paradigms, such as Software-Defined Networking (SDN), the switches facilitate seamless integration into existing infrastructure while optimizing resource utilization. Cisco's Application Centric Infrastructure (ACI) technology enhances application performance and availability across diverse workloads and applications.

The 5000 Series delivers superior performance with fixed and modular configurations tailored to different operational demands. This flexibility allows businesses to select from various models that best fit their specific needs, whether they require high-density 10, 25, 40, or 100 Gigabit Ethernet connectivity. The series supports high throughput and low latency, making it ideal for data-intensive applications such as virtualization and real-time data processing.

High availability is another critical aspect of the Cisco 5000 Series, which incorporates redundant hardware components and advanced configuration options. Features like Hot Swappable Power Supplies and Fans ensure minimal downtime during maintenance activities. Additionally, these switches come equipped with comprehensive features for network visibility and monitoring, including Cisco’s In-Service Software Upgrade (ISSU) capabilities that allow for continuous operations during updates.

Security is paramount in today’s networking landscape, and the Cisco 5000 Series is equipped with advanced security features. These include support for Virtual LANs (VLANs), Access Control Lists (ACLs), and advanced threat detection mechanisms. Cisco Identity Services Engine (ISE) integration provides granular control over user access and policy enforcement, creating a secure environment for sensitive data.

In summary, the Cisco Systems 5000 Series is a powerful solution designed for modern networking challenges, featuring hybrid deployment capabilities, robust performance metrics, high availability, and advanced security protocols. Businesses deploying these switches benefit from scalability and flexibility, ensuring their network can adapt to evolving demands while maintaining optimal performance and security.