Cisco Systems 2960S-24TS-S manual Device Crossover Cable1, Switch to switch Yes Switch to hub

Page 55

Chapter 2 Switch Installation

10/100 and 10/100/1000 PoE+ Port Connections

Warning Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such interconnection methods, unless the exposed metal parts are located within a restricted access location and users and service people who are authorized within the restricted access location are made aware of the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key or other means of security. Statement 1072

Caution Category 5e and Category 6 cables can store high levels of static electricity. Always ground the cables to a suitable and safe earth ground before connecting them to the switch or other devices.

Step 1 Connect one end of the cable (Table 2-1) to the switch PoE port.

Step 2 Connect the other end of the cable to an RJ-45 connector on the other device. The port LED turns on when both devices have established link.

The port LED is amber while STP discovers the topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green. If the LED is off, the other device might not be turned on, there might be a cable problem, or there might be a problem with the adapter in the other device. See Chapter 3, “Troubleshooting,” for solutions to cabling problems.

Caution Noncompliant cabling or powered devices can cause a PoE port fault. Use only standard-compliant cabling to connect Cisco prestandard IP Phones and wireless access points or IEEE 802.3af-compliant devices. You must remove any cable or device that causes a PoE fault.

Step 3 Reconfigure and reboot the connected device if needed.

Step 4 Repeat Steps 1 through 3 to connect each device.

Note Many legacy powered devices, including older Cisco IP phones and access points that do not fully support IEEE 802.3af, might not support PoE when connected to the switches by a crossover cable.

The autonegotiation and the auto-MDIX features are enabled by default on the switch.

With autonegotiation, the switch port configurations change to operate at the speed of the attached device. If the attached device does not support autonegotiation, you can manually set the switch interface speed and duplex parameters.

With auto-MDIX, the switch detects the required cable type for copper Ethernet connections and configures the interface accordingly. If auto-MDIX is disabled, use Table 2-1to select the correct cable.

See the “Cables and Adapters” section on page B-3for pinout descriptions.

Table 2-1 Recommended Ethernet Cables (When Auto-MDIX is Disabled)

 

 

Device

Crossover Cable1

Straight-Through Cable1

 

 

 

Switch to switch

Yes

No

 

 

 

 

 

 

 

 

Switch to hub

Yes

No

 

 

 

 

 

 

 

 

 

 

 

Catalyst 2960-S Switch Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-19732-04

 

 

 

 

2-25

 

 

 

 

 

 

 

Image 55
Contents Americas Headquarters Catalyst 2960-S Switch Hardware Installation GuidePage N T E N T S Connecting to Fiber-Optic SFP and SFP+ Modules Uninstalling the Cisco Microsoft Windows USB Driver C-5 Catalyst 2960-S Switch Hardware Installation Guide Preface Related Publications Obtaining Documentation and Submitting a Service RequestSupported Switch Model Switch ModelsDescription Catalyst 2960S-48FPD-L Front Panel Front PanelCatalyst 2960S-48TS-L Front Panel Catalyst 2960S-F48FPS-L Front Panel 10/100/1000 PoE+ Ports 10/100 PoE+ Ports10/100/1000 Ports 10/100 PortsUSB Mini-Type B Port Management PortsSFP and SFP+ Module Slots USB Type a PortSupported SFP Modules SFP-H10GB-CU3M= Supported SFP+ ModulesSFP-10G-LRM= SFP-H10GB-CU1M=Color System Status LEDsSystem LED RPS 1 LEDPort LEDs and Modes Port Mode DescriptionMode LED Port Mode Description Master LEDColor PoE Status Port Mode Port LED Color MeaningSpeed Stack10/100 and 10/100/1000 ports Stack member 1 3 Stack member Stack LEDConsole LEDs show which console port is in use Console LEDsColor Description Ethernet Management Port LED Rear Panel12 Catalyst 2960-S Switch Rear Panel with an RPS connector Fan exhaust AC power connector RPS connectorCisco RPS RPS ConnectorFan exhaust AC power connector FlexStack PortsManagement Options AC Power ConnectorNetwork Configurations OL-19732-04 Read these topics and perform the procedures in this order Safety WarningsPreparing PWR-RPS2300Statement 113F 45C. Statement Box Contents Installation GuidelinesTools and Equipment Verifying Switch Operation Planning a Switch StackStack Guidelines Switch Installation Planning a Switch Stack Secure the screws tightly on each side of the module Installing the FlexStack ModuleStack Bandwidth and Partitioning Examples Stack CablingStack with Half Bandwidth Connections Power-On Sequence for Switch Stacks Installing the SwitchRack-Mounting 10 Rack-Mounting Brackets Attaching the Rack-Mount Brackets12 Attaching Brackets for 19-inch Racks 13 Mounting in a Rack Mounting in a RackAttaching the Brackets for Wall-Mounting Wall-MountingPhillips truss-head screws Statement Attaching the RPS Connector Cover16 Mounting on a Wall Mounting on a WallAfter Switch Installation Connecting the FlexStack CablesTable- or Shelf-Mounting 18 Inserting the Retainer through the Lanced Loop Installing the Power Cord Retainer Optional19 Sliding the Retainer Through the Latch Slide the retainer through the first latch. See Figure21 Sleeve Around the Power Cord Installing SFP and SFP+ ModulesRemoving an SFP or SFP+ Module Installing an SFP or SFP+ ModuleConnecting to Fiber-Optic SFP and SFP+ Modules Connecting to SFP and SFP+ Modules24 Connecting to a Fiber-Optic SFP Module Port Connecting to 1000BASE-T SFP10/100 and 10/100/1000 PoE+ Port Connections RJ-45 connectorDevice Crossover Cable1 Switch to switch Yes Switch to hub10/100 and 10/100/1000 Port Connections Where to Go NextDevice Crossover Cable Switch Post Results Diagnosing ProblemsSwitch LEDs Link Status Switch ConnectionsBad or Damaged Cable Ethernet and Fiber-Optic CablesSFP and SFP+ Module Interface Settings10/100 or 10/100/1000 Port Connections 10/100 or 10/100/1000 PoE Port ConnectionsSpeed, Duplex, and Autonegotiation Switch PerformancePing End Device Spanning Tree LoopsFinding the Switch Serial Number Clearing the Switch IP Address and ConfigurationCabling Distance Troubleshooting Finding the Switch Serial Number Serial Number Location for the C2960S-STACK Module Serial Number Location for the C2960S-F-STACK Module Replacing a Failed Stack Member OL-19732-04 Environmental Ranges Technical SpecificationsPower Requirements Physical Dimensions Power Requirements Physical Dimensions OL-19732-04 10/100 Ports Including PoE Connector Specifications10/100/1000 Ports Including PoE SFP Module ConnectorsSFP Module Cables Cables and Adapters1000BASE-LX/LH 1000BASE-SXGLC-SX-MM GLC-TCable Pinouts Two Twisted-Pair Straight-Through Cable SchematicConsole Port Adapter Pinouts Switch Console RJ-45-to-DB-9 Port DTEDevice Switch Console RJ-45-to-DB-25 Port DTE OL-19732-04 Accessing the CLI Through the Console Port Accessing the CLI Through Express SetupConnecting the RJ-45 Console Port or USB Console Port Installing the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows Vista USB Driver Installing the Cisco Microsoft Windows 2000 USB DriverUninstalling the Cisco Microsoft Windows Vista USB Driver Uninstalling the Cisco Microsoft Windows USB DriverIP Settings Entering the Initial Configuration InformationCompleting the Setup Program Switch or as a standalone switch Enter an enable password, and press ReturnEnter a virtual terminal Telnet password, and press Return Application. To configure Snmp later, enter noThese choices appear 10/100/1000 PoE ports Numbering NumericsIN-2 Rack-mounting 2-10 to SFP and SFP+ modulesStatus RPSLED Post Restricted access area RPS connector cover IN-6
Related manuals
Manual 16 pages 38.2 Kb Manual 108 pages 14.27 Kb Manual 28 pages 25.34 Kb

2960S, WSC2960S24TSSRF, 2960S-24TS-S, 2960 specifications

Cisco Systems 2960 series switches are a prominent solution in the networking landscape, known for their reliability, scalability, and feature-rich offerings. Ideal for small to medium-sized enterprises, these switches provide a robust foundation for network infrastructure, ensuring optimal performance and connectivity.

One of the standout features of the Cisco 2960 series is its Layer 2 switching capabilities. The switches support multiple VLANs (Virtual Local Area Networks), allowing network administrators to segment traffic efficiently and enhance security protocols. This is crucial in modern networks where managing traffic and isolating sensitive information is a priority.

The Cisco 2960 series also incorporates advanced Quality of Service (QoS) features, enabling the prioritization of critical applications and services. This functionality ensures that time-sensitive data, such as voice and video traffic, maintains a high quality of service even in congested networks. With support for IEEE 802.1p and DSCP marking, administrators can fine-tune their network performance to meet specific organizational needs.

Power over Ethernet (PoE) is another significant characteristic of the Cisco 2960 series. This feature allows switches to deliver electrical power alongside data over Ethernet cables to devices such as IP phones, wireless access points, and surveillance cameras. With PoE, organizations can reduce clutter from power cables and increase deployment flexibility for various devices.

In terms of security, the Cisco 2960 series is equipped with a range of integrated security features. The switch supports port security, 802.1X authentication, and Access Control Lists (ACLs), providing robust defenses against unauthorized access and potential network vulnerabilities. These security measures are essential for protecting sensitive data and ensuring compliance with industry regulations.

Moreover, the Cisco 2960 series offers enhanced network management capabilities with Cisco's Intelligent Network Services. This includes support for Simple Network Management Protocol (SNMP), Cisco Prime, and Embedded Event Manager (EEM), allowing for efficient monitoring, troubleshooting, and policy enforcement across the network.

Additionally, the Cisco 2960 switches provide various models and configurations, catering to different networking needs. Options include models with varying port densities, uplink configurations, and stacking capabilities, making it easy for organizations to choose solutions that align perfectly with their requirements.

In summary, the Cisco 2960 series is a versatile and essential component of modern networking environments. Its advanced features, including Layer 2 support, QoS, PoE, robust security, and diverse management tools, make it an excellent choice for organizations looking to build a strong and secure network infrastructure.