Cisco Systems WSC2960S24TSSRF, 2960S-24TS-S manual Accessing the CLI Through Express Setup

Page 81

A P P E N D I X C

Configuring the Switch with the CLI-Based

Setup Program

This appendix provides a CLI-based setup procedure for a Catalyst 2960-S standalone switch or a switch stack. Before you turn on the switch power, review the safety warnings in Chapter 2, “Switch Installation.”

Accessing the CLI Through Express Setup

You can access the CLI on an unconfigured switch. Set the switch in Express Setup mode and connect a switch Ethernet port to an Ethernet port on your PC or workstation. Follow the steps described in the getting started guide for turning on the switch and using Express Setup.

When the switch is in Express Setup mode, open a Telnet session to the switch by entering the IP address 10.0.0.1. Enter the setup user EXEC command. Enter the information described in the “IP Settings” section on page C-6and the “Completing the Setup Program” section on page C-6.

After you have entered the configuration information for the switch, save it to flash memory by using the write memory privileged EXEC command.

Note In Express Setup mode, the IP address 10.0.0.1 remains active on the switch until you enter the write memory command. You lose the Telnet connection after entering the write memory command.

For information about using the CLI, see the switch command reference for this release.

Accessing the CLI Through the Console Port

You can access the CLI on a configured or unconfigured switch by connecting the RJ-45 console port or USB console port of the switch to your PC or workstation and accessing the switch through a terminal emulation program.

Note If you have stacked your switches, connect to the console port of one of the switches in the stack. You can initially configure the entire stack from any member switch.

Catalyst 2960-S Switch Hardware Installation Guide

 

OL-19732-04

C-1

 

Image 81
Contents Americas Headquarters Catalyst 2960-S Switch Hardware Installation GuidePage N T E N T S Connecting to Fiber-Optic SFP and SFP+ Modules Uninstalling the Cisco Microsoft Windows USB Driver C-5 Catalyst 2960-S Switch Hardware Installation Guide Preface Related Publications Obtaining Documentation and Submitting a Service RequestSwitch Models Supported Switch ModelDescription Catalyst 2960S-48FPD-L Front Panel Front PanelCatalyst 2960S-48TS-L Front Panel Catalyst 2960S-F48FPS-L Front Panel 10/100/1000 PoE+ Ports 10/100 PoE+ Ports10/100/1000 Ports 10/100 PortsUSB Mini-Type B Port Management PortsSFP and SFP+ Module Slots USB Type a PortSupported SFP Modules SFP-10G-LRM= Supported SFP+ ModulesSFP-H10GB-CU1M= SFP-H10GB-CU3M=System LED LEDsRPS 1 LED Color System StatusMode LED Port Mode Description Port Mode DescriptionMaster LED Port LEDs and ModesSpeed Port Mode Port LED Color MeaningStack Color PoE Status10/100 and 10/100/1000 ports Stack member 1 3 Stack member Stack LEDConsole LEDs Console LEDs show which console port is in useColor Description Ethernet Management Port LED Rear Panel12 Catalyst 2960-S Switch Rear Panel with an RPS connector Fan exhaust AC power connector RPS connectorFan exhaust AC power connector RPS ConnectorFlexStack Ports Cisco RPSManagement Options AC Power ConnectorNetwork Configurations OL-19732-04 Safety Warnings Read these topics and perform the procedures in this orderPreparing PWR-RPS2300Statement 113F 45C. Statement Installation Guidelines Box ContentsTools and Equipment Planning a Switch Stack Verifying Switch OperationStack Guidelines Switch Installation Planning a Switch Stack Secure the screws tightly on each side of the module Installing the FlexStack ModuleStack Bandwidth and Partitioning Examples Stack CablingStack with Half Bandwidth Connections Installing the Switch Power-On Sequence for Switch StacksRack-Mounting 10 Rack-Mounting Brackets Attaching the Rack-Mount Brackets12 Attaching Brackets for 19-inch Racks 13 Mounting in a Rack Mounting in a RackWall-Mounting Attaching the Brackets for Wall-MountingPhillips truss-head screws Statement Attaching the RPS Connector Cover16 Mounting on a Wall Mounting on a WallConnecting the FlexStack Cables After Switch InstallationTable- or Shelf-Mounting 18 Inserting the Retainer through the Lanced Loop Installing the Power Cord Retainer Optional19 Sliding the Retainer Through the Latch Slide the retainer through the first latch. See Figure21 Sleeve Around the Power Cord Installing SFP and SFP+ ModulesRemoving an SFP or SFP+ Module Installing an SFP or SFP+ ModuleConnecting to Fiber-Optic SFP and SFP+ Modules Connecting to SFP and SFP+ Modules24 Connecting to a Fiber-Optic SFP Module Port Connecting to 1000BASE-T SFP10/100 and 10/100/1000 PoE+ Port Connections RJ-45 connectorDevice Crossover Cable1 Switch to switch Yes Switch to hubWhere to Go Next 10/100 and 10/100/1000 Port ConnectionsDevice Crossover Cable Diagnosing Problems Switch Post ResultsSwitch LEDs Bad or Damaged Cable Switch ConnectionsEthernet and Fiber-Optic Cables Link Status10/100 or 10/100/1000 Port Connections Interface Settings10/100 or 10/100/1000 PoE Port Connections SFP and SFP+ ModulePing End Device Switch PerformanceSpanning Tree Loops Speed, Duplex, and AutonegotiationClearing the Switch IP Address and Configuration Finding the Switch Serial NumberCabling Distance Troubleshooting Finding the Switch Serial Number Serial Number Location for the C2960S-STACK Module Serial Number Location for the C2960S-F-STACK Module Replacing a Failed Stack Member OL-19732-04 Environmental Ranges Technical SpecificationsPower Requirements Physical Dimensions Power Requirements Physical Dimensions OL-19732-04 10/100 Ports Including PoE Connector Specifications10/100/1000 Ports Including PoE SFP Module ConnectorsSFP Module Cables Cables and AdaptersGLC-SX-MM 1000BASE-SXGLC-T 1000BASE-LX/LHCable Pinouts Two Twisted-Pair Straight-Through Cable SchematicSwitch Console RJ-45-to-DB-9 Port DTE Console Port Adapter PinoutsDevice Switch Console RJ-45-to-DB-25 Port DTE OL-19732-04 Accessing the CLI Through the Console Port Accessing the CLI Through Express SetupConnecting the RJ-45 Console Port or USB Console Port Installing the Cisco Microsoft Windows XP USB Driver Installing the Cisco Microsoft Windows USB Device DriverInstalling the Cisco Microsoft Windows Vista USB Driver Installing the Cisco Microsoft Windows 2000 USB DriverUninstalling the Cisco Microsoft Windows Vista USB Driver Uninstalling the Cisco Microsoft Windows USB DriverEntering the Initial Configuration Information IP SettingsCompleting the Setup Program Enter a virtual terminal Telnet password, and press Return Enter an enable password, and press ReturnApplication. To configure Snmp later, enter no Switch or as a standalone switchThese choices appear 10/100/1000 PoE ports Numbering NumericsIN-2 Rack-mounting 2-10 to SFP and SFP+ modulesRPS StatusLED Post Restricted access area RPS connector cover IN-6
Related manuals
Manual 16 pages 38.2 Kb Manual 108 pages 14.27 Kb Manual 28 pages 25.34 Kb

2960S, WSC2960S24TSSRF, 2960S-24TS-S, 2960 specifications

Cisco Systems 2960 series switches are a prominent solution in the networking landscape, known for their reliability, scalability, and feature-rich offerings. Ideal for small to medium-sized enterprises, these switches provide a robust foundation for network infrastructure, ensuring optimal performance and connectivity.

One of the standout features of the Cisco 2960 series is its Layer 2 switching capabilities. The switches support multiple VLANs (Virtual Local Area Networks), allowing network administrators to segment traffic efficiently and enhance security protocols. This is crucial in modern networks where managing traffic and isolating sensitive information is a priority.

The Cisco 2960 series also incorporates advanced Quality of Service (QoS) features, enabling the prioritization of critical applications and services. This functionality ensures that time-sensitive data, such as voice and video traffic, maintains a high quality of service even in congested networks. With support for IEEE 802.1p and DSCP marking, administrators can fine-tune their network performance to meet specific organizational needs.

Power over Ethernet (PoE) is another significant characteristic of the Cisco 2960 series. This feature allows switches to deliver electrical power alongside data over Ethernet cables to devices such as IP phones, wireless access points, and surveillance cameras. With PoE, organizations can reduce clutter from power cables and increase deployment flexibility for various devices.

In terms of security, the Cisco 2960 series is equipped with a range of integrated security features. The switch supports port security, 802.1X authentication, and Access Control Lists (ACLs), providing robust defenses against unauthorized access and potential network vulnerabilities. These security measures are essential for protecting sensitive data and ensuring compliance with industry regulations.

Moreover, the Cisco 2960 series offers enhanced network management capabilities with Cisco's Intelligent Network Services. This includes support for Simple Network Management Protocol (SNMP), Cisco Prime, and Embedded Event Manager (EEM), allowing for efficient monitoring, troubleshooting, and policy enforcement across the network.

Additionally, the Cisco 2960 switches provide various models and configurations, catering to different networking needs. Options include models with varying port densities, uplink configurations, and stacking capabilities, making it easy for organizations to choose solutions that align perfectly with their requirements.

In summary, the Cisco 2960 series is a versatile and essential component of modern networking environments. Its advanced features, including Layer 2 support, QoS, PoE, robust security, and diverse management tools, make it an excellent choice for organizations looking to build a strong and secure network infrastructure.